The use of parturient-controlled epidural analgesia (PCEA) with a basal infusion is commonly used in laboring women. We compared a novel approach of providing basal intermittent boluses concurrently with PCEA: PCEA plus automated mandatory boluses (PCEA+AMB) versus PCEA plus basal continuous infusion (PCEA+BCI). We hypothesized that epidural local anesthetic consumption would be lower if basal intermittent boluses were used instead of a basal infusion. We randomized 42 healthy parturients in early labor to receive 0.1% ropivacaine + fentanyl 2 microg/mL either via PCEA+BCI (n = 21,bolus 5 mL, lockout 10 min, basal infusion 5 mL/h) or via PCEA+AMB (n = 21, patient-activated bolus of 5 mL, lockout 10 min, basal automated boluses of 5 mL/h [omitted if a patient-activated bolus was successfully administered in the last 1 h]) after successful induction of combined spinal epidural analgesia. We found a reduction in the hourly consumption of ropivacaine with PCEA+AMB, i.e., the primary outcome measure (mean = 6.5 mL, sd = 3.4 in the PCEA+AMB group vs 7.5 mL, sd = 2.0 PCEA+BCI group, P = 0.011). A larger proportion of parturients in the PCEA+AMB group did not self-bolus (6/21 vs 1/21 in PCEA+BCI, P = 0.03). The time to the first self-bolus after combined spinal epidural was longer in the PCEA+AMB group (mean survival time 315 min vs 190 min in PCEA+BCI group, P = 0.04 by log rank test). There was no difference in pain scores or side effects. Our study showed that PCEA+AMB reduced analgesic consumption and could be useful as the mode of maintenance for epidural analgesia.
1 April 2005 in International Journal of Obstetric Anesthesia
The LMA Protector™ is the latest CE marked single use supraglottic airway device. This airway device provides access and functional separation of the respiratory and digestive tracts. There are two ports (male, female ports) to provide suction in the laryngeal region and insertion of the gastric tube. The aim of our study is to assess the ease of use, airway quality, device positioning, airway leak and complications associated with initial clinical experience in LMA Protector™ usage. This is an initial investigation of LMA Protector™ airway device. We conducted a preliminary assessment in the anaesthetised women who underwent minor gynaecological procedures with spontaneous ventilation in order to evaluate the performance of the airway device. Insertion was successful on first and second attempts in 23 (88.5%) and 3 (11.5%) respectively. Median [IQR (range)] insertion time was 19 [17-21(14-58)] seconds. Airway leak pressure was 25.5 [23-29(21-30] cmH2O. On fibreoptic examination via the device, vocal cords were visible in all 26 patients. There were no alternative airway use or airway manipulations required during maintenance of anaesthesia. Six patients had sore throat 24 h after procedures and there was no dysphagia or hoarseness. This pilot study of the LMA protector shows that the device is easily inserted with fast insertion time, providing a reliable and adequate airway seal. Clinicaltrials.gov Registration NCT02531256 . Retrospectively registered on August 21, 2015.
Neuraxial procedures are commonly performed for therapeutic and diagnostic indications. Currently, they are typically performed via palpation-guided surface landmark. We devised a novel intelligent image processing system that identifies spinal landmarks using ultrasound images. Our primary aim was to evaluate the first attempt success rate of spinal anesthesia using landmarks obtained from the automated spinal landmark identification technique. In this prospective cohort study, we recruited 100 patients who required spinal anesthesia for surgical procedures. The video from ultrasound scan image of the L3/4 interspinous space in the longitudinal view and the posterior complex in the transverse view were recorded. The demographic and clinical characteristics were collected and analyzed based on the success rates of the spinal insertion. Success rate (95%CI) for dural puncture at first attempt was 92.0% (85.0–95.9%). Median time to detection of posterior complex was 45.0 [IQR: 21.9, 77.3] secs. There is good correlation observed between the program-recorded depth and the clinician-measured depth to the posterior complex (r = 0.94). The high success rate and short time taken to obtain the surface landmark with this novel automated ultrasound guided technique could be useful to clinicians to utilise ultrasound guided neuraxial techniques with confidence to identify the anatomical landmarks on the ultrasound scans. Future research would be to define the use in more complex patients during the administration of neuraxial blocks. This study was retrospectively registered on clinicaltrials.gov registry ( NCT03535155 ) on 24 May 2018.
Epidural analgesia is a popular choice for labour pain relief. Patient satisfaction is an important patient-centric outcome because it can significantly influence both mother and child. However, there is limited evidence in the correlations between clinical determinants and patient satisfaction. We aim to investigate clinical covariates that are associated with low patient satisfaction in parturients receiving labour neuraxial analgesia. After institutional ethics approval was obtained, we conducted a retrospective cohort study using electronic and corresponding hardcopy records from 10,170 parturients receiving neuraxial analgesia between the periods of January 2012 to December 2013 in KK Women’s and Children’s Hospital in Singapore. Demographic, obstetric and anesthetic data were collected. The patient satisfaction scores on the neuraxial labour analgesia was reported by the parturient at 24 to 48 h post-delivery during the post-epidural round conducted by the resident and pain nurse. Parturients were stratified into one of three categories based on their satisfaction scores. Ordinal logistic regression models were used to identify potential covariates of patient dissatisfaction. 10,146 parturients were included into the study, of which 3230 (31.8%) were ‘not satisfied’, 3646 (35.9%) were ‘satisfied’, and 3270 (32.2%) were ‘very satisfied’. Multivariable ordinal logistic regression analysis showed that instrument-assisted vaginal delivery (p = 0.0007), higher post-epidural pain score (p = 0.0016), receiving epidural catheter resiting (p < 0.0001), receiving neuraxial analgesia at a more advanced cervical dilation (p = 0.0443), multiparity (p = 0.0039), and post-procedure complications headache (p = 0.0006), backache (p < 0.0001), urinary retention (p = 0.0002) and neural deficit (p = 0.0297) were associated with patient dissatisfaction. Chinese, compared with other ethnicities (p = 0.0104), were more likely to be dissatisfied. Our study has identified several clinical determinants that were independent associated factors for low patient satisfaction. These covariates could be useful in developing a predictive model to detect at-risk parturients and undertake time-sensitive precautionary measures for better patient satisfaction.