Ozgul SALOR

Dr. Ozgul SALOR

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2016 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
EUEda Uz-Logoglu
Eda Uz-Logoglu
OSOzgul SALOR
Ozgul SALOR
MEMuammer Ermiş
Muammer Ermiş
In this paper, a multiple synchronous reference frame (MSRF) analysis framework is developed to determine the positive- and negative-sequence components of all interharmonic and harmonic currents produced by alternating current electric arc furnace (AC EAF) installations, which can be considered as balanced but asymmetrical three-phase, three-wire loads on the power system. The aim of developing the MSRF analysis framework is twofold; deep understanding of the EAF characteristics, and fast and accurate generation of reference signals to the controllers of the advanced technology compensation systems such as active power filters (APFs), synchronous static compensators (STATCOMs), and energy storage systems (ESS), which may successfully compensate interharmonics, harmonics, and flicker. Online characterization of interharmonics and harmonics by MSRF analysis utilizes continuously measured line currents and line voltages on the medium-voltage side of the EAF transformer at a sampling rate of 25.6-kHz per data channel. It has been shown by offline computations that compensation of the sequence components of interharmonics and harmonics of the EAF currents obtained by the proposed framework, reduces the short-term flicker values at the point of common coupling by up to 10-fold. The proposed MSRF analysis framework has been successfully verified by comparing the frequency spectrums of the EAF currents with Fourier analysis results based on one-cycle sliding windows of 10-cycle duration.

27 February 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
EBEbrahim Balouji
Ebrahim Balouji
KBKarl Backstrom
Karl Backstrom
TMTomas McKelvey
Tomas McKelvey
OSOzgul SALOR
Ozgul SALOR
In this article, a new approach to compensate both the response and reaction times of active power filters (APF) for special cases of highly time-varying harmonics and interharmonics of electric arc furnace (EAF) currents is proposed. Instead of using the classical approach of taking a window of past current samples and analyzing the data, future samples of EAF currents are predetected using a deep learning (DL)-based method and then analyzed, which provides the opportunity to make real-time analysis. This can also serve the needs of other possible APF applications. Two different methods for prediction of future samples of harmonics and interharmonics have been proposed: predetection of harmonics and interharmonics in the time domain (TD) and in the frequency domain (FD). To obtain the best possible accuracy for both methods, grid search has been employed for parameter optimization of the DL structure. Both TD and FD approaches have been tested on field data, which had been obtained from transformer substations supplying EAF plants. It is shown that the response time of the APF algorithms can be compensated using the TD-based approach, while it is possible to compensate both the response and reaction times of APFs using the proposed FD-based approach. The developed method can be considered to be a feasible candidate solution for generating reference signals for the controllers of new generation of compensation devices, which can be referred to as predictive APFs.

22 March 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
EBEbrahim Balouji
Ebrahim Balouji
OSOzgul SALOR
Ozgul SALOR
TMTomas McKelvey
Tomas McKelvey
In this research work, deep machine learning-based methods together with a novel data augmentation are developed for predicting flicker, voltage dip, harmonics, and interharmonics originating from highly time-varying electric arc furnace (EAF) currents and voltage. The aim with the prediction is to counteract both the response and reaction time delays of active power filters (APFs) specifically designed for electric arc furnaces (EAF). Multiple synchronous reference frame (MSRF) analysis is used to decompose the frequency components of the EAF current and voltage waveforms into dqo components. Then using low-pass filters and prediction of the future values of these dqo components, reference signals for APFs are generated. Three different methods have been developed. In two of them, a low-pass Butterworth filter is used together with a linear finite impulse response (FIR)-based prediction or long short-term memory network (LSTM) for prediction. In the third method, a deep convolutional neural network (CNN) combined with a LSTM network is used to filter and predict at the same time. For a 40-ms prediction horizon, the proposed methods provide 2.06%, 0.31%, 0.99% prediction errors of the dqo components for the Butterworth and linear prediction, Butterworth and LSTM, and CNN with LSTM, respectively. The error of the predicted reconstructed waveforms of flicker, harmonics, and interharmonics resulted in 8.5%, 1.90%, and 3.2% reconstruction errors for the abovementioned methods. Finally, a Simulink and GPU-based implementation of predictive APF using Butterworth filter + LSTM and a trivial APF resulted 96% and 60% efficiency on compensation of EAF current interharmonics.

16 April 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ESErhan Sezgin
Erhan Sezgin
OSOzgul SALOR
Ozgul SALOR
In this paper, a hybrid time-frequency analysis method, specially developed to decompose harmonic subgroups and interharmonics of the electric arc furnace (EAF) currents, which are highly time varying due to the operation principles of the EAFs, is presented. The main objective is accurate perception of harmonics and interharmonics in cases of rapid changes or power quality (PQ) events in power system voltages and currents. Harmonic and interharmonics detection has been achieved using discrete wavelet transform (DWT), which provides time-localization in cases of highly time-varying signals. Although DWT elicits accurate spectral decomposition at low frequencies, and especially at the baseband, bandwidths of the band-pass filters increase which results in loss of accuracy at higher frequencies. In order to avoid this problem, power signals are modulated by complex exponential waveforms, which corresponds to shifting the required harmonic sub-band contents to the baseband, where the accuracy of the DWT is the best. Using the proposed hybrid combination of DWT and complex exponential modulation, time domain waveform of each harmonic sub-band of the EAF currents can be estimated close to ideal values. The method also enables to focus on any required interharmonic sub-band in addition to the harmonics. To optimize the performance of the DWT in cases of PQ events, various windowing approaches are discussed. The proposed harmonic and interharmonic estimation method has been verified on both synthetic data and EAF currents collected from the electricity transmission system. Estimated harmonic and interharmonic waveforms can serve as a good reference in many areas including active power filtering operations, limit violation determinations, etc., in the power system.

15 July 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
EUEda Uz-Logoglu
Eda Uz-Logoglu
OSOzgul SALOR
Ozgul SALOR
MEMuammer Ermiş
Muammer Ermiş
In this paper, a method based on the multiple synchronous reference frame (MSRF) analysis is recommended and implemented to detect time-varying harmonics and interharmonics of rapidly fluctuating asymmetrical industrial loads. The experimental work has been carried out on a typical three-phase alternating current arc furnace (AC EAF) installation. In the recommended method, the reference frame is rotated in both directions at speeds corresponding to the positive and negative sequences of all harmonics and all interharmonics 5-Hz apart. To extract the direct current (DC) components of the transformed d-q quantities, a low-pass filter is employed. In order to keep the delay of the filter at zero frequency less than a few ms, Kalman estimation technique has been used. Back transformation is then applied for each harmonic and interharmonic component to obtain their positive- and negative- sequences of the associated harmonic and interharmonic in the actual line current waveforms. Parallel computing technique has been applied for the real-time detection of both the phase and the amplitude of all harmonics and interharmonics. This is achieved on NVDIA Jetson TX1 graphics processing unit (GPU) framework for a sample industrial plant. The developed system is shown to be useful for fast and accurate generation of reference signals for the controllers of the advanced technology power conditioning systems which successfully compensates interharmonics, harmonics, and flicker of the rapidly fluctuating nonlinear industrial loads.

21 September 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
NSNagihan Severoglu
Nagihan Severoglu
OSOzgul SALOR
Ozgul SALOR
In this research work, a deep learning (DL) based method for the fast and accurate analysis of current harmonics of Electric Arc Furnaces (EAF) is proposed. For such a system, a large amount of EAF current data is required for the training phase of the DL-based structure, which is not only a thorny but also an expensive procedure. Hence, the second focus of this research work is to gain the ability to generate EAF currents with realistic harmonic contents based on a much smaller amount of field data of EAF currents recorded during a tap-to-tap time of the EAF. For this purpose, examination of the EAF current harmonics is achieved on the field data collected at a transformer substation supplying an EAF plant. Then, a significantly larger amount of EAF current data is regenerated mimicking the real EAF behavior to train the DL-based harmonic estimator. This estimator is able to estimate both amplitudes and phases of the harmonics without computing any time- or frequency-domain features during the estimation process. Hence the outcomes of this research work are two-fold: First, detailed analysis of the EAF current harmonic behavior is achieved. Second, a DL-based harmonic estimator is trained, which is able to output amplitude and phase estimations directly out of waveform samples without any feature extraction. The proposed system aims to serve the needs of active power filters of the EAF installations in the electricity system, since it has been shown that fast and accurate harmonic amplitude and phase estimations are obtained.