Christina Iosif

Prof. Dr. Christina Iosif

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
CIChristina Iosif
Christina Iosif
CMC. Mounayer
C. Mounayer
KYK. Yavuz
K. Yavuz
SSS. Saleme
S. Saleme
SGSerdar Geyik
Serdar Geyik
ISI. Saatci
I. Saatci
BACKGROUND AND PURPOSE: Flow diverters have been increasingly used lately in off-label, distal intracranial aneurysm treatments. Our aim was to evaluate the effectiveness of flow diverters in the treatment of middle cerebral artery bifurcation aneurysms and to analyze midterm angiographic patterns of regional flow modifications for safety and clinical outcomes. MATERIALS AND METHODS: Consecutive patients treated from January 2010 to December 2014 by the authors by using endovascular flow-diverting stents for MCA bifurcation aneurysms were evaluated retrospectively with prospectively maintained data. All patients had been followed for at least 12 months after treatment, with at least 2 control angiograms; regional flow-related angiographic modifications were registered by using a new angiographic outcome scale for flow diverters. Data were analyzed with emphasis on procedure-related events, angiographic results, and clinical outcome. RESULTS: Fifty-eight patients were included in the study, with 63 MCA bifurcation aneurysms; 13 of these were large and giant. Pretreatment mRS was 0 for 12 patients (20.7%), 1 for 41 (70.7%), and 2 for 5 patients (8.6%). Six-month control revealed mRS 0–2 for 57 (98.3%) patients and 3 for 1 (1.7%) patient. Procedure-related morbidity and mortality were 8.6% (5/58) and 0%, respectively. From 95% of still circulating immediate postprocedure angiographic outcomes, 68% progressed to aneurysm occlusion at 6 months and 95%, to occlusion at 12 months, with a 0% aneurysm rupture rate. CONCLUSIONS: Flow diverters seem to be an effective treatment alternative for complex MCA bifurcation aneurysms, with reasonable complication rates. Longer angiographic follow-ups are needed to assess the morphologic outcome; immediate subtotal occlusions do not seem to be related to rupture.

24 November 2017 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
CIChristina Iosif
Christina Iosif
MPMichel Piotin
Michel Piotin
SSSuzana Saleme
Suzana Saleme
XBXavier Barreau
Xavier Barreau
JSJacques Sedat
Jacques Sedat
CMCharbel Mounayer
Charbel Mounayer
Background and purpose To evaluate the safety and effectiveness of the low-profile braided intracranial stents called the Low Profile Visualized Intraluminal Support (LVIS) devices for stent-assisted coil embolization of wide-necked intracranial aneurysms. Materials and methods This was a prospective, multicenter, observational study of unruptured and ruptured intracranial aneurysms treated with the LVIS devices. Imaging and clinical data were independently analyzed respectively by CoreLab and Clinical Event Committee. Primary endpoints were clinical safety, effectiveness, and angiographic stability of the results at 6 and 18 months. Results Ten centers participated in the study; 102 patients were included and 90 patients (42.2% men, 57.8% women) were eventually analyzed, among which 27 (30.0%) had multiple aneurysms. Twenty-three (25.6%) were ruptured aneurysms, four of which (4.4%) were treated in the acute phase. One aneurysm was treated per patient; 92 LVIS and LVIS Jr devices were placed overall. The total aneurysm occlusion rate was 91.0% on immediate post-procedure angiograms, which remained unchanged at 6-month follow-up and was 92.4% at 18-month follow-up. One patient (1.1%) underwent retreatment between 6 and 18 months of follow-up. A modified Rankin score of 0 was documented for most cases immediately after the procedure (86.7%) and at 6-month (86.8%) and 18-month (83.3%) follow-up. The overall permanent morbidity rate at 18 months was 5.6% and the overall rate of events with sequelae related to the stent was 2.2%. The 18-month procedure-related mortality rate was 3.3%. No patient was deemed to require retreatment at 18-month follow-up. Conclusion The LVIS/LVIS Jr endovascular devices are safe and effective in the treatment of ruptured and unruptured intracranial aneurysms, with acceptable complication rates, very high immediate total occlusion rates, and stable angiographic results.

29 October 2020 in American Journal of Neuroradiology
Verified
Journal Article
Open access
JSJ.M.B. De Sousa
J.M.B. De Sousa
CIChristina Iosif
Christina Iosif
LSL.Z. Sganzerla
L.Z. Sganzerla
ARA.N. Rafie
A.N. Rafie
VBVladimir Borodetsky
Vladimir Borodetsky
CMC. Mounayer
C. Mounayer
Intracranial hemorrhage represents a severe complication of brain arteriovenous malformation treatment. The aim of this cohort was to report the rate of hemorrhagic complications after transvenous endovascular embolization and analyze the potential angioarchitectural risk factors as well as clinical outcomes. During an 11-year period, 57 patients underwent transvenous endovascular embolization. All cases of hemorrhagic complications were identified. We analyzed the following variables: sex, age, hemorrhagic presentation, Spetzler-Martin grade, size of the AVM before the transvenous treatment, number of venous collectors, pattern of drainage, presence of dilated veins, and technical aspects. Univariate and multivariate multiple regression analyses were performed to evaluate the potential risk factors for procedure-related hemorrhagic complications. Hemorrhagic complications (either intraprocedural or periprocedural) unrelated to a perforation due to micronavigation occurred in 8 (14.0%) procedures. Significant (mRS > 2) and persistent neurologic deficits were present in 2 (3.5%) patients at 6-month control. Larger nidi, especially >3 cm (P = .03), and a larger number of venous collectors have shown a statistically significant correlation with hemorrhagic complications. Only the number of venous collectors was identified as an independent predictor of hemorrhagic complications in the multivariate analysis (OR, 8.7; 95% confidence interval, 2.2-58.2) (P = .006). Larger nidus sizes and an increased number of venous collectors may increase the risk of hemorrhagic complications when implementing transvenous endovascular treatment of AVMs. The technique is effective and promising, especially with small nidi and single venous collectors.

1 April 2018 in Journal of Neurosurgery
Verified
Journal Article
Closed access
CIChristina Iosif
Christina Iosif
JLJean-Christophe Lecomte
Jean-Christophe Lecomte
EPEduardo Pedrolo-Silveira
Eduardo Pedrolo-Silveira
GMGeorge Mendes
George Mendes
MMMarie-Paule Boncoeur Martel
Marie-Paule Boncoeur Martel
CMCharbel Mounayer
Charbel Mounayer
OBJECTIVE: Even though published data exist concerning the prevalence of ischemic lesions detected by diffusion-weighted imaging (DWI) following endovascular treatment of intracranial aneurysms, a single-center cross-evaluation of the different endovascular techniques has been lacking. The authors sought to prospectively evaluate the prevalence and clinical significance of ischemic lesions occurring after endovascular treatment of intracranial aneurysms and to compare the safety and effectiveness of a broad spectrum of currently accepted endovascular techniques in a single-center setting.METHODS: This was a prospective cohort study involving consecutive patients treated for intracranial aneurysms exclusively by endovascular means, excluding treatments in the acute rupture phase, in a center featuring an endovascular-only treatment policy for intracranial aneurysms. All patients underwent MRI, including a 3-directional DWI sequence, before treatment, 24 hours postprocedure, and 6 months following endovascular embolization. Selective angiography was performed at 6 months’ follow-up.RESULTS: From January 2012 through December 2013, 164 aneurysms were treated in 128 consecutive patients. Endovascular techniques included coiling (14.6%), balloon-assisted coiling (20.1%), stent-assisted coiling (3.7%), low-profile stent-assisted coiling, flow diversion (38.4%), and very complex treatments (6.1%) involving 2 stents in Y or T configurations. On postprocedure MRI, the rates of occurrence of new DWI-positive lesions were 64.3% for coiling, 54.5% for remodeling, 61.1% for stent-assisted coiling, 53.7% for flow-diverting stents, and 75% for very complex treatments (p = 0.4962). The 6-month procedure-related morbidity and mortality rates were 6.25% and 0%, respectively. At 6 months’ follow-up, 93% of the patients had modified Rankin Scale (mRS) scores of 0–2. Very complex treatments offered a higher complete occlusion rate (100%) than all other techniques (66.7%–88.9%). Age and length of procedure were independent factors for DWI lesion occurrence. The diameter of DWI lesions on 24-hour postprocedure MRI was positively correlated with mRS score at discharge. Among the DWI-positive lesions measuring less than 2 mm in diameter on the 24-hour MRI, 44.12% had regressed at 6 months.CONCLUSIONS: Procedure-related DWI lesions are far more often encountered in silent forms than they are clinically evident. They do not seem to be significantly correlated with procedure-related complications, nor do they seem to impair clinical outcome, regardless of the endovascular technique. Small lesions (< 2 mm in diameter) may regress within 6 months. The use of the most adapted technique, in terms of aneurysm configuration, results in significant total occlusion rates, with acceptable safety.

12 January 2022 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
CIChristina Iosif
Christina Iosif
JFJose Alberto Almeida Filho
Jose Alberto Almeida Filho
CGClara Esther Gilbert
Clara Esther Gilbert
ARAli Nazemi Rafie
Ali Nazemi Rafie
SSSuzana Saleme
Suzana Saleme
CMCharbel Mounayer
Charbel Mounayer
Background The technique of endovascular transvenous embolization for brain arteriovenous malformations (AVMs) has emerged in the last 8 years as a very promising therapeutic alternative for otherwise incurable cases. Selective temporary flow arrest during transvenous endovascular embolization (TFATVE) is a novel adaptation of our previously described transvenous approach, which employs hyper-compliant balloons intra-arterially for the selective occlusion of arterial feeders during ethylene vinyl copolymer (EVOH) injection, in order to reduce intra-nidal pressure and increase nidi occlusion rates. Methods We performed a feasibility study of the TFATVE technique between January 2016 and April 2020. Consecutive patients were included. All patients had at least one axial brain MRI or CT in the first 48 hours following intervention, and at least one brain MRI scan within the first postoperative month, in order to detect both silent and clinically evident adverse events. Patients’ demographics, angio-architectural characteristics, total injection and procedure times, angiographic and clinical outcomes were analyzed. Results 22 patients underwent TFATVE during transvenous endovascular treatment of brain AVMs. Among them, 86.4% were high Spetzler-Martin’s grade. Good clinical outcome (modified Rankin Scale 90% of the cases at the end of the procedure and angiographic stability was achieved in all cases; 100% of the cases had angiographic cure at follow-up. Conclusions TFATVE seems a safe and effective technique when conducted in carefully selected patients in highly specialized centers.

1 May 2017 in Journal of Neurosurgery
Verified
Journal Article
Closed access
CIChristina Iosif
Christina Iosif
PBPhilipp Berg
Philipp Berg
SPSebastien Ponsonnard
Sebastien Ponsonnard
PCPierre Carles
Pierre Carles
SSSuzana Saleme
Suzana Saleme
CMCharbel Mounayer
Charbel Mounayer
OBJECTIVE: The outcome for jailing arterial branches that emerge near intracranial aneurysms during flow-diverting stent (FDS) deployment remains controversial. In this animal study, the authors aimed to elucidate the role of collateral supply with regard to the hemodynamic changes and neointimal modifications that occur from jailing arteries with FDSs. To serve this purpose, the authors sought to quantify 1) the hemodynamic changes that occur at the jailed arterial branches immediately after stent placement and 2) the ostia surface values at 3 months after stenting; both parameters were investigated in the presence or absence of collateral arterial flow.METHODS: After an a priori power analysis, 2 groups (Group A and Group B) were created according to an animal flow model for terminal and anastomotic arterial circulation; each group contained 7 Large White swine. Group A animals possessed an anastomotic-type arterial configuration to supply the territory of the right ascending pharyngeal artery (APhA), while Group B animals possessed a terminal-type arterial configuration to supply the right APhA territory. Subsequently, all animals underwent FDS placement, thereby jailing the right APhAs. Mean flow rates and velocities inside the jailed branches were quantified using time-resolved 3D phase-contrast MR angiography before and after stenting. Three months after stent placement, the jailed ostia surface values were quantified on scanning electron micrographs. The data were analyzed using descriptive statistics and group comparisons with parametric and nonparametric tests.RESULTS: The endovascular procedures were feasible, and there were no findings of in situ thrombus formation on postprocedural optical coherence tomography or ischemia on postprocedural diffusion-weighted imaging. In Group A, the mean flow rate values at the jailed right APhAs were reduced immediately following stent placement as compared with values obtained before stent placement (p = 0.02, power: 0.8). In contrast, the mean poststenting flow rates for Group B remained similar to those obtained before stent placement. Three months after stent placement, the mean ostia surface values were significantly higher for Group B (527,911 ± 306,229 μm2) than for Group A (89,329 ± 59,762 μm2; p < 0.01, power: 1.00), even though the initial dimensions of the jailed ostia were similar between groups. A statistically significant correlation was found between groups (A or B), mean flow rates after stent placement, and ostia surface values at 3 months.CONCLUSIONS: When an important collateral supply was present, the jailing of side arteries with flow diverters resulted in an immediate and significant reduction in the flow rate inside these arteries as compared with the prestenting values. In contrast, when competitive flow was absent, jailing did not result in significant flow rate reductions inside the jailed arteries. Ostium surface values at 3 months after stent placement were significantly higher in the terminal group of jailed arteries (Group B) than in the anastomotic group (Group A) and strongly correlated with poststenting reductions in the velocity value.