Lu Rong

Prof. Dr. Lu Rong

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2011 in Optics Express
Verified
Journal Article
Open access
PDF file
MSMatthew D. Seaberg
Matthew D. Seaberg
DADaniel E. Adams
Daniel E. Adams
ETEthan L. Townsend
Ethan L. Townsend
DRDaisy A. Raymondson
Daisy A. Raymondson
WSWilliam F. Schlotter
William F. Schlotter
MMMargaret M. Murnane
Margaret M. Murnane
New diffractive imaging techniques using coherent x-ray beams have made possible nanometer-scale resolution imaging by replacing the optics in a microscope with an iterative phase retrieval algorithm. However, to date very high resolution imaging (< 40nm) was limited to large-scale synchrotron facilities. Here, we present a significant advance in image resolution and capabilities for desktop soft x-ray microscopes that will enable widespread applications in nanoscience and nanotechnology. Using 13nm high harmonic beams, we demonstrate a record 22nm spatial resolution for any tabletop x-ray microscope. Finally, we show that unique information about the sample can be obtained by extracting 3-D information at very high numerical apertures.

13 February 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LRLu Rong
Lu Rong
TLTatiana Latychevskaia
Tatiana Latychevskaia
CCChunhai Chen
Chunhai Chen
DWDayong Wang
Dayong Wang
ZYZhengping Yu
Zhengping Yu
ZZZhou Zhou
Zhou Zhou
Terahertz waves provide a better contrast in imaging soft biomedical tissues than X-rays and unlike X-rays, they cause no ionisation damage, making them a good option for biomedical imaging. Terahertz absorption imaging has conventionally been used for cancer diagnosis. However, the absorption properties of a cancerous sample are influenced by two opposing factors: an increase in absorption due to a higher degree of hydration and a decrease in absorption due to structural changes. It is therefore difficult to diagnose cancer from an absorption image. Phase imaging can thus be critical for diagnostics. We demonstrate imaging of the absorption and phase-shift distributions of 3.2 mm × 2.3 mm × 30-μm-thick human hepatocellular carcinoma tissue by continuous-wave terahertz digital in-line holography. The acquisition time of a few seconds for a single in-line hologram is much shorter than that of other terahertz diagnostic techniques and future detectors will allow acquisition of meaningful holograms without sample dehydration. The resolution of the reconstructions was enhanced by sub-pixel shifting and extrapolation. Another advantage of this technique is its relaxed minimal sample size limitation. The fibrosis indicated in the phase distribution demonstrates the potential of terahertz holographic imaging to obtain a more objective, early diagnosis of cancer.

8 July 2014 in Optics Express
Verified
Journal Article
Open access
PDF file
LRLu Rong
Lu Rong
TLTatiana Latychevskaia
Tatiana Latychevskaia
DWDayong Wang
Dayong Wang
XZXun Zhou
Xun Zhou
HHHaochong Huang
Haochong Huang
YWYunxin Wang
Yunxin Wang
We report here on terahertz (THz) digital holography on a biological specimen. A continuous-wave (CW) THz in-line holographic setup was built based on a 2.52 THz CO2 pumped THz laser and a pyroelectric array detector. We introduced novel statistical method of obtaining true intensity values for the pyroelectric array detector’s pixels. Absorption and phase-shifting images of a dragonfly’s hindwing were reconstructed simultaneously from single in-line hologram. Furthermore, we applied phase retrieval routines to eliminate twin image and enhanced the resolution of the reconstructions by hologram extrapolation beyond the detector area. The finest observed features are 35 μm width cross veins.

23 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YZYaya Zhang
Yaya Zhang
CWChuting Wang
Chuting Wang
BHBingxin Huai
Bingxin Huai
SWShiyu Wang
Shiyu Wang
YZYating Zhang
Yating Zhang
YZYongChang Zheng
YongChang Zheng
In the past few decades, the applications of terahertz (THz) spectroscopy and imaging technology have seen significant developments in the fields of biology, medical diagnosis, food safety, and nondestructive testing. Label-free diagnosis of malignant tumours has been obtained and also achieved significant development in THz biomedical imaging. This review mainly presents the research status and prospects of several common continuous-wave (CW) THz medical imaging systems and applications of THz medical imaging in biological tissues. Here, we first introduce the properties of THz waves and how these properties play a role in biomedical imaging. Then, we analyse both the advantages and disadvantages of the CW THz imaging methods and the progress of these methods in THz biomedical imaging in recent ten years. Finally, we summarise the obstacles in the way of the application of THz bio-imaging application technology in clinical detection, which need to be investigated and overcome in the future.

1 January 2010 in Chinese Optics Letters
Verified
Journal Article
Closed access
LRLu Rong
Lu Rong
WXWen Xiao
Wen Xiao
FPFeng Pan
Feng Pan
SLShuo Liu
Shuo Liu
RLRui Li
Rui Li
A novel speckle reduction technique for digital holography is proposed. Multiple off-axis holograms are recorded using a circularly polarized illumination beam and a rotating linearly polarized reference beam. The speckle noise in the reconstructed images is suppressed by averaging these fields. We demonstrate the effectiveness of this technique experimentally and conduct additional statistical evaluation.

13 August 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
YWYunxin Wang
Yunxin Wang
PMPuhui Meng
Puhui Meng
DWDayong Wang
Dayong Wang
LRLu Rong
Lu Rong
SPSpozmai Panezai
Spozmai Panezai
A speckle noise suppression method in digital holography is proposed by the angular diversity with a phase-only spatial light modulator (SLM). The minimal angular difference of illumination beams is quantitatively analyzed to ensure the noncorrelation of any two speckle patterns, and then the phase-only SLM is employed to generate a series of tilted illumination beams. Comparing with the typical methods, the tilted illumination beams are controlled dynamically and accurately, which makes it possible to record a large number of holograms. Finally, using an image-plane digital holographic system, 117 holograms are recorded respectively, and the synthesized reconstructed images are obtained with the greatly suppressed speckle noise which is in good agreement with the theoretical results. The experimental results demonstrate the effectiveness, repeatability, and practicability of the proposed approach.