Chagas disease (CD) is recognized as one of the major neglected global tropical diseases. Benznidazole (BNZ) is the drug of choice for the treatment of adults, young infants, and newborns with CD. However, the pharmacokinetics (PK) of BNZ have been poorly evaluated in all age groups, with consequent gaps in knowledge about PK-pharmacodynamic relationships in CD. The purpose of this study was to develop and validate a bioanalytical method to quantify BNZ levels in small-volume whole-blood samples collected as dried blood spots (DBS). The analysis was performed using high-performance liquid chromatography-positive electrospray tandem mass spectrometry. PK evaluation in healthy male volunteers was conducted to verify the correlation between DBS and plasma BNZ concentrations. The calibration curve was linear from 50 to 20,000 ng · ml−1. Intra- and interday precision and bias values were less than 14.87% (n = 9) and 9.81% (n = 27), respectively. The recovery rates ranged from 94 to 100% with no matrix effect. There was no hematocrit level effect in a range of 20 to 70%. The PK results obtained from DBS and plasma were comparable (r2 = 0.8295) and equivalent to previously published information on BNZ. BNZ in DBS was stable at room temperature for more than one year. This article describes the first microsampling method for measuring BNZ levels in DBS that has the potential to facilitate broad implementation of PK in clinical trials involving adult and pediatric patients in remote areas and helps to address existing knowledge gaps in the treatment of CD.
Background/Objectives: Leishmaniasis is one of the 20 Neglected Tropical Diseases according to the WHO, affecting approximately 12 million people in four continents, generating serious public health problems. The lack of therapeutic options, associated with toxicity and the emergence of resistance to the few available drugs, makes it urgent to develop new drug options. In this context, the aims of this work are to expand the knowledge about the pharmacophore group responsible for the antileishmanial potential of 2-aminothiophene derivatives. Thus, new compounds were synthesized containing chemical modifications at the C-3, C-4, and C-5 positions of the 2-aminothiophene ring, in addition to the S-Se bioisosterism. Methods: Dozens of 2-AT and 2-aminoselenophen (2-AS) derivatives were sequentially synthesized through applications of the Gewald reaction and were then evaluated in vitro for their activities against L. amazonensis and for cytotoxicity against macrophages. Results: Several series of compounds were synthesized, and it was possible to identify some substitution patterns favorable to the activity generating compounds with IC50 values below 10 µM, such as the non-essentiality of the presence of a carbonitrile group at C-3; the importance of the presence and size of cycloalkyl/piperidinyl chains at C-4 and C-5 in modulating the activity; and the increase in activity without affecting the safety of the S/Se bioisosteric substitution. Conclusions: Taken together, these findings reaffirm the great potential of 2-aminothiophenes to generate antileishmanial drug candidates and offers contributions to the drug design of compounds with an even more promising profile for the problem of leishmaniasis.
4 May 2021 in Drug Development and Industrial Pharmacy
To perform the solid-state characterization and the in vitro-in vivo correlation (IVIVC) of three batches of efavirenz (EFV) active pharmaceutical ingredients.EFV is an effective anti-HIV drug. Due...
1 April 2020 in Environmental Toxicology and Pharmacology
An LC-MS/MS method has been developed for the determination of efavirenz (EFZ) in human plasma using hydrochlorothiazide as internal standard (I.S.). An ESI negative mode with multiple reaction-monitoring was used monitoring the transitions m/z 313.88→69.24 (EFZ) and 296.02→204.76 (I.S.). Samples were extracted using liquid-liquid extraction. The total run time was 2.0 min. The separation was achieved with HPLC-RP using a monolithic column. The assay was linear in the concentration range of 100 - 5000 ng mL-1. The mean recovery was 83%. Intra- and inter-day precision were < 9.5% and < 8.9%, respectively and accuracy was in the range ± 8.33%. The method was successfully applied to a bioequivalence study