Federico Cecati

Dr. Federico Cecati

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FCFederico Cecati
Federico Cecati
RZRongwu Zhu
Rongwu Zhu
Marco LiserreMarco Liserre
Marco Liserre
XWXiongfei Wang
Xiongfei Wang
Power system state-space models are often constructed by interconnection of their subsystems (converters, distribution lines, and grid). The interconnection between L-/LCL-filtered converters with the distribution lines subsystems is often realized through a virtual resistor, because they both have the voltage as input, introducing inaccuracy. Moreover, the parameters variations influence not only the eigenvalues, but also the equilibrium point. In this case, the small-signal model has to be reevaluated around the new equilibrium point. For the computation of the equilibrium point, an additional method, e.g., power flow, is conventionally used. However, the variables computed with power flow (e.g., ${\rm P},Q,{\rm V},\text{ and }\theta$) do not always coincide with the state-space model variables, required for the linearization. Furthermore, the traditional power flow does not consider the influence of the voltage-source-converter control system on the grid equilibrium point. This article proposes a nonlinear grid model that does not need the virtual resistor to be interconnected. The proposed model can be used both for equilibrium point computation through the Newton–Raphson method, and it can be linearized around the computed equilibrium point for small-signal analyses. Simulations and experiments are provided.

18 July 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FCFederico Cecati
Federico Cecati
RZRongwu Zhu
Rongwu Zhu
SPSante Pugliese
Sante Pugliese
Marco LiserreMarco Liserre
Marco Liserre
XWXiongfei Wang
Xiongfei Wang
Admittance reshaping is a widely used strategy to address the converters low-frequency stability issues in weak grid, caused by the PLL and its interaction with the dc and ac voltage controls. However, the asymmetric control of the $d$ - and $q$ -axis current references and the coupling between the converter ac and dc sides restricts the damping capability of single-input single-output feedbacks. This phenomenon gets even worse in the presence of nearby converters. This article extends the concept of admittance reshaping to multi-input multi-output control. A full state feedback is added to the current reference of the converter to increase the damping of the conventional multiloop control. A systematic offline algorithm is delegated to design the feedback, and a scalar coefficient is employed to activate/deactivate online the reshaping feedback, making the proposed solution user-friendly. The proposed control is analyzed both in time and frequency domains and tested in parallel-operation with other converters, and shows higher damping capability than conventional solutions and good robustness with respect to grid impedance and operating point variations. Experimental tests under ac and dc disturbances are conducted both in lab setup and in hardware-in-the-loop.

13 December 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
FCFederico Cecati
Federico Cecati
JBJohanna Kristin Maria Becker
Johanna Kristin Maria Becker
SPSante Pugliese
Sante Pugliese
YZYihui Zuo
Yihui Zuo
Marco LiserreMarco Liserre
Marco Liserre
MPMario Paolone
Mario Paolone
As known, nonlinear loads in power systems originate harmonic distortion and power quality issues. Converter-interfaced loads exhibit a nonlinear behaviour as well and may largely contribute to increase the harmonic pollution. The nonlinearities introduced by the PLL-synchronization and power control originate, indeed, a coupling mechanism between fundamental and harmonic frequencies. These harmonic coupling effects are not captured by traditional Norton/Thevenin equivalent converter models, leading to inaccurate harmonic power flow analyses. This paper proposes a Linear Time Periodic model of a PLL-synchronized converter to be used in Harmonic Power Flow analyses. A realistic 18-bus distribution grid hosting substantial amount of power-electronic interfaced resources is used as a case study. It is revealed that, in high grid loadability condition and with distorted grid supply voltage, the harmonics are significantly amplified by the converters and the fundamental components of the buses voltages are reduced, representing a risk for the voltage stability. This phenomenon is also influenced by the tuning of the current control loop and the PLL. The accuracy of the presented analyses is validated by comparing the harmonic power flow results with time-domain simulations.

25 October 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
JBJohanna Kristin Maria Becker
Johanna Kristin Maria Becker
AKAndreas Martin Kettner
Andreas Martin Kettner
YZYihui Zuo
Yihui Zuo
FCFederico Cecati
Federico Cecati
SPSante Pugliese
Sante Pugliese
MPMario Paolone
Mario Paolone
Modern power distribution systems experience a large-scale integration of Converter-Interfaced Distributed Energy Resources (CIDERs). As acknowledged by recent literature, the interaction of individual CIDER components and different CIDERs through the grid can lead to undesirable amplification of harmonic frequencies and, ultimately, compromise the distribution system stability. In this context, the interaction of the DC and AC sides of CIDERs has been shown to have a significant impact. In order to analyze and support the mitigation of such phenomena, the authors of this paper recently proposed a Harmonic Power-Flow (HPF) framework for polyphase grids with a high share of CIDERs. The framework considers the coupling between harmonics, but ignores the DC-side response of the CIDERs. Modelling the DC side and the AC/DC converter introduces a nonlinearity into the CIDER model that needs to be approximated for the numerical solution of the HPF. This paper extends the CIDER model and HPF framework to address this aspect, whose inclusion is non-trivial. The extended HPF method is applied to a modified version of the CIGRÈ low-voltage benchmark microgrid. The results are compared to (i) time-domain simulations with Simulink, (ii) the predecessor of the extended HPF which neglects the DC side, and (iii) a classical decoupled HPF.

27 March 2025 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
FCFederico Cecati
Federico Cecati
Marco LiserreMarco Liserre
Marco Liserre
Stability of multi-vendor power electronics-dominated grids requires proper specifications for converters interoperability, e.g., tuning boundaries for the converters’ control loops to be respected by all vendors. The confidentiality and variety of implementation of the converters’ control system by different vendors and the nonlinear dynamics of power converters make this task arduous. This paper formulates this research question as a robust stability problem, embedding frequency-dependent uncertainties in the converter control systems and analytically quantifying the amount of uncertainty able to warranty the power grid stability. Grid following converters are considered and modeled with a nonlinear grey-box approach, in contrast with conventional small-signal black-box models which suffer from inaccuracy when their operating point deviates from the nominal one. This paper also demonstrates both analytically and with Hardware-In-the-Loop (HIL) experiments that different converters operating points (e.g., active power injections, ac bus voltages) radically affect their stability, empathizing the necessity of nonlinear converters models to realize accurate power grid stability analyses.

4 October 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
GAGalo D. Astudillo
Galo D. Astudillo
HBHamzeh Beiranvand
Hamzeh Beiranvand
FCFederico Cecati
Federico Cecati
CWChristian Werlich
Christian Werlich
AWAndreas Würsig
Andreas Würsig
Marco LiserreMarco Liserre
Marco Liserre
During fast charging of Lithium-Ion batteries (LIB), cell overheating and overvoltage increase safety risks and lead to faster battery deterioration. Moreover, in conventional Battery Management Systems (BMS), the cell balancing, charging strategy and thermal regulation are treated separately at the expense of faster cell deterioration. Hence, this paper proposes an optimized fast charging and balancing strategy with electro-thermal regulation of LIB packs. Thereby, the power dissipation constraints of the passive balancing are introduced in the proposed integrated optimal framework and cell balancing is achieved by bypassing the extra charging current. The electro-thermal model of the cells, along with a battery pack formed by a string of cells, is implemented. Extensive experiments are carried out to identify the coefficients for the Lithium-Ion cell model, i.e. Samsung-INR18650-20R, and the charging current trajectory as well as the balancing signals are generated with Model Predictive Control (MPC). The pack level simulations and experiments show that the proposed algorithm maintains the electro-thermal boundaries throughout the charging process, increasing the safe charge acceptance of the battery pack.