Nitin Pandey

Dr. Nitin Pandey

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
MJMamta Juneja
Mamta Juneja
ISIshaan Singla
Ishaan Singla
APAditya Poddar
Aditya Poddar
NPNitin Pandey
Nitin Pandey
AGAparna Goel
Aparna Goel
PBPhilip Breedon
Philip Breedon
Cranioplasty enables the restoration of cranial defects caused by traumatic injuries, brain tumour excisions, or decompressive craniectomies. Conventional methods rely on Computer-Aided Design (CAD) for implant design, which requires significant resources and expertise. Recent advancements in Artificial Intelligence (AI) have improved Computer-Aided Diagnostic systems for accurate and faster cranial reconstruction and implant generation procedures. However, these face inherent limitations, including the limited availability of diverse datasets covering different defect shapes spanning various locations, absence of a comprehensive pipeline integrating the preprocessing of medical images, cranial reconstruction, and implant generation, along with mechanical testing and validation. The proposed framework incorporates a robust preprocessing pipeline for easier processing of Computed Tomography (CT) images through data conversion, denoising, Connected Component Analysis (CCA), and image alignment. At its core is CRIGNet (Cranial Reconstruction and Implant Generation Network), a novel deep learning model rigorously trained on a diverse dataset of 2160 images, which was prepared by simulating cylindrical, cubical, spherical, and triangular prism-shaped defects across five skull regions, ensuring robustness in diagnosing a wide variety of defect patterns. CRIGNet achieved an exceptional reconstruction accuracy with a Dice Similarity Coefficient (DSC) of 0.99, Jaccard Similarity Coefficient (JSC) of 0.98, and Hausdorff distance (HD) of 4.63 mm. The generated implants showed superior geometric accuracy, load-bearing capacity, and gap-free fitment in the defected skull compared to CAD-generated implants. Also, this framework reduced the implant generation processing time from 40–45 min (CAD) to 25–30 s, suggesting its application for a faster turnaround time, enabling decisive clinical support systems.

26 May 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
MJMamta Juneja
Mamta Juneja
MKMaanya Kharbanda
Maanya Kharbanda
NPNitin Pandey
Nitin Pandey
ASAgrima Sudhir
Agrima Sudhir
APAditya Poddar
Aditya Poddar
PBPhilip Breedon
Philip Breedon
Maxillofacial defects impair facial aesthetics and oral function, arising from trauma, tumor resection, or congenital anomalies; however, reconstruction using Computer-Aided Design (CAD) and autologous grafts remains complex and time-intensive, and is associated with donor-site morbidity. Although deep learning (DL) has advanced automated reconstruction, existing models often address isolated tasks, lack integrated multi-scale feature learning, and rely on small datasets. This study proposes the Maxillofacial Implant-generation Network (MaxI-Net), a fast, resource-efficient three-dimensional DL framework for end-to-end maxillofacial defect reconstruction and patient-specific implant generation, with a completion step of cavity filling within the assembly. The model employs a 3D encoder–bottleneck-decoder architecture integrating hybrid dilated convolutions, residual connections, squeeze-and-excitation (SE) blocks, and 3D Convolutional Block Attention Modules (CBAM) with multi-scale feature fusion. It was trained on 921 Cone Beam-Computed Tomography (CBCT) scans, augmented to 11,973 maxillary defect pairs, using Dice loss and Adam optimisation with Automatic Mixed Precision, and benchmarked against UNet, UNETR, SegResNet, and SwinUNETR. MaxI-Net achieved the following: superior Dice Similarity Coefficient (DSC) = 0.778; 95th percentile Hausdorff Distance (HD95) = 3.453 mm; DSC Standard Deviation (SD) = 0.094; 95% confidence interval (CI) for mean DSC: 0.775–0.782). It was statistically validated against all competing architectures via pairwise Wilcoxon signed-rank tests, with significant DSC improvements confirmed across all comparators (p < 0.001) and rank-biserial effect sizes ranging from r = 0.250 against the closest competitor SegResNet* with high efficiency (0.06 s/volume; 9.6 min/epoch). Internal cavity filling of the generated implants was performed as a brief manual post-processing step in Autodesk Fusion 360 prior to biomechanical validation. Biomechanical validation using a finite element analysis (FEA) of polyether–ether–ketone (PEEK) implants (~26.53 g) showed 41% stress reduction under physiological loads (100–400 N), predicting a ~9.2-year lifespan.

2 April 2026 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
SSSumindar Kaur Saini
Sumindar Kaur Saini
MJMamta Juneja
Mamta Juneja
NANaveen Aggarwal
Naveen Aggarwal
NPNitin Pandey
Nitin Pandey