This study aimed at investigating if a coating of hydroxyapatite nanocrystals would enhance bone healing over time in trabecular bone. Sandblasted and acid etched titanium implants with and without a submicron thick coat of hydroxyapatite nanocrystals (nano-HA) were implanted in rabbit femur with healing times of 2, 4, and 9 weeks. Removal torque analyses and histological evaluations were performed. The torque analysis did not show any significant differences between the implants at any healing time. The control implant showed a tendency of more newly formed bone after 4 weeks of healing and significantly higher bone area values after 9 weeks of healing. According to the results from this present study, both control and nano-HA surfaces were biocompatible and osteoconductive. A submicron thick coating of hydroxyapatite nanocrystals deposited onto blasted and acid etched screw shaped titanium implants did not enhance bone healing, as compared to blasted and etched control implants when placed in trabecular bone.
This study evaluated the effect of smoke exposure on the expression of genes related to bone metabolism in implants coated with nanohydroxyapatite (NHA). A total of 36 rats were exposed to cigarette smoke for 60 days. The animals were allocated into three groups: machined implants (MAC), dual acid-etched implants (DAE), and NHA-coated implants (NHA). Implants were installed in the left tibia of the rats after 30 days of smoke exposure. The implants were retrieved 7 and 30 days after implantation, and the adjacent bone analyzed using a real-time polymerase chain reaction for gene expression of alkaline phosphatase (ALP), osteopontin (OPN), receptor activator of the nuclear factor kappa ligand (RANKL), osteoprotegerin (OPG), the RANKL/OPG ratio, osteocalcin (OCN) and runt-related transcription factor 2 (Runx2). After 7 days, Runx2, OPN and OPG expression demonstrated significantly higher levels for the NHA surface treatment relative to DAE and MAC surfaces. NHA presented the lowest RANKL and RANKL/OPG levels. After 30 days, NHA-coated implants showed significantly higher levels of Runx2, ALP, OPN, OPG, OC, RANKL and RANKL/OPG relative to DAE and MAC implants. The results indicated a greater osteogenic and high osteoclastic activity around NHA implants, in comparison to DAE and MAC implants.
Leukocyte–platelet-rich fibrin (L-PRF) contains growth factors that stimulate bone regeneration. This study evaluated the bone repair in a tibia rat model around two implant surfaces in combination or not with L-PRF by assessing microtomographic and histomorphometric parameters. A total of 48 female rats were used in the study, in which 24 received implants with two types of surface treatments (dual acid etched—DAE or nanohydroxyapatite—nanoHA), and the other 24 received the same mini implants with L-PRF, which was collected by cardiac puncture, centrifugated, and inserted in the bone bed. The animals were euthanized 7 and 30 days after implant placement, and the retrieved samples were prepared for microtomographic and histomorphometric (bone-to-implant contact—BIC; and Bone Area Fraction Occupancy—BAFO) analyses. The adhesion of the nanoHA surface onto the implant surface was investigated by insertion and removal in simulated bone medium (Sawbones). The adhesion evaluation revealed that the loss of nanoHA after this procedure (as measured with SEM) from the implant surface was less than 1%. Overall, the nanoHA surface presented more bone in contact and in proximity to the implant, a higher bone surface/tissue volume fraction, a higher number of bone trabeculae, as well as trabecular separation relative to the DAE surface. Such results were more evident when the nanoHA surface was combined with L-PRF and after 30 days in vivo. The nanoHA surface presented higher BAFO when compared to DAE, with or without association with L-PRF. Therefore, implants with a nanoHA surface potentially benefit from the association to L-PRF.
30 September 2022 in Journal of Materials Science: Materials in Medicine
Percutaneous implants are frequently affected by bacterial growth at the skin-implant interface. Integration between implant and surrounding skin is important to prevent bacteria from spreading to the underlying tissue. The standard method to evaluate skin-implant integration is by histomorphometry on samples which have been placed in tissue grown in vivo or ex vivo. In this study, a biomechanical method was developed and evaluated. The integration of implants into porcine skin was studied in an ex vivo model, where pig skin samples were cultivated in a nutrient solution. Cylindrical shaped implants, consisting of polyether ether ketone (PEEK) and titanium (Ti) with different surface treatments, were implanted in the skin tissue and the skin was grown in nutrient solution for 2 weeks. The implants were then extracted from the implantation site and the mechanical force during extraction was measured as a quantitative assessment of skin-implant integration. Implants from each group were also processed for histomorphometry and the degree of epidermal downgrowth (ED) and tissue to implant contact (TIC) was measured. A higher mean pullout force was observed for the PEEK implants compared to the Ti implants. Applying nanosized hydroxyapatite (HA) on Ti and PEEK increased the pullout force compared to uncoated controls, 24% for machined and 70% for blasted Ti, and 51% for machined PEEK. Treatment of Ti and PEEK with nanosized zirconium phosphate (ZrP) did not increase the pullout force. The histomorphometry analysis showed correlation between ED and pullout force, where the pullout force was inversely proportional to ED. For TIC, no significant differences were observed between the groups of same material (i.e. Ti, Ti+HA, Ti+ZrP, and PEEK, PEEK + HA, PEEK + ZrP), but it was significantly higher for PEEK compared to Ti. Scanning electron microscopy analysis was done on samples before and after the pullout tests, showing that the ZrP coating was unaffected by the 2 week ex vivo implantation and pullout procedure, no dissolution or detachment of the coating was observed. For the HA coating, a loss of coating was seen on approximately 5% of the total surface area of the implant.