As the concept of integrated diagnosis and treatment gains increasing prominence, the utilization of radiopharmaceuticals in personalized medicine has garnered unprecedented attention. However, the production of these radiopharmaceuticals continues to encounter numerous technical challenges. It plays an important role in improving the efficiency and convenience of nuclear medicine services and can quickly and conveniently provide the required radioactive isotopes to meet the needs of integrated clinical diagnosis and treatment while reducing dependence on external supplies and improving safety and the economy. At present, commonly used medical radioactive isotope generators include 99Mo/99mTc, 68Ge/68Ga, 90Sr/90Y, 188W/188Re, etc. This article reviews the latest research progress on three main medical radioactive isotope generators of 99Mo/99mTc, 68Ge/68Ga, and 90Sr/90Y. It also evaluates the highly anticipated new 44Ti/44Sc generator and proposes research prospects for current medical radioactive isotope generators, providing exploration directions for the future development of nuclear medicine.
Rare earth elements (REEs) have significant application value in the quality control of nuclear materials and in traceability research in nuclear forensics. Methods were developed for the determination of REEs in uranium-bearing nuclear materials. The digestion parameters for uranium oxides and uranium ores, such as the digestion acid, digestion temperature, and digestion time, were optimized and reported. The optimized digestion parameters for uranium oxides were 2 mL HNO3 at 160 °C for 3 h, and those for uranium ores were 7 mL mixed acid (HNO3–HClO4–HF = 5:5:3) at 180 °C for 36 h. Two digestion methods were demonstrated to be effective for the quantitative recovery of REEs. The suitable system and specifications for different resin columns were investigated to achieve a high decontamination factor of U (105) by UTEVA resin. The corresponding loading system was 10 mL 4 M HNO3, and the elution system was 6 mL 4 M HNO3. Additionally, the analysis of ultra-trace REEs in high-uranium matrices was accomplished using two UTEVA resins. The developed methods were subjected to the Cochran test and the Grubbs test, and the relative standard deviation (RSD) for all REEs was below 6%. In uranium oxide samples with different spiked amounts, the recovery of REEs exceeded 80% in all cases, and the RSDs were all less than 10%. The method’s detection limits were below 10 ppt for all REEs (except for Ce), ensuring the accurate measurement of REEs in uranium-bearing nuclear materials.