Lijuan Xiong

Prof. Dr. Lijuan Xiong


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2020 in Journal of Medical Virology
Verified
Journal Article
Closed access
PDF file
YCYinghao Cao
Yinghao Cao
XLXiaoling Liu
Xiaoling Liu
LXLijuan Xiong
Lijuan Xiong
KCKailin Cai
Kailin Cai

24 October 2016 in Critical Care
Verified
Journal Article
Open access
PDF file
YFYunzhou Fan
Yunzhou Fan
FGFang Gao
Fang Gao
YWYanyan Wu
Yanyan Wu
JZJie Zhang
Jie Zhang
MZMing Zhu
Ming Zhu
LXLijuan Xiong
Lijuan Xiong
Ventilator-associated event (VAE) is a new surveillance paradigm for monitoring complications in mechanically ventilated patients in intensive care units (ICUs). The National Healthcare Safety Network replaced traditional ventilator-associated pneumonia (VAP) surveillance with VAE surveillance in 2013. The objective of this study was to assess the consistency between VAE surveillance and traditional VAP surveillance. We systematically searched electronic reference databases for articles describing VAE and VAP in ICUs. Pooled VAE prevalence, pooled estimates (sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV)) of VAE for the detection of VAP, and pooled estimates (weighted mean difference (WMD) and odds ratio ([OR)) of risk factors for VAE compared to VAP were calculated. From 2191 screened titles, 18 articles met our inclusion criteria, representing 61,489 patients receiving mechanical ventilation at ICUs in eight countries. The pooled prevalence rates of ventilator-associated conditions (VAC), infection-related VAC (IVAC), possible VAP, probable VAP, and traditional VAP were 13.8 %, 6.4 %, 1.1 %, 0.9 %, and 11.9 %, respectively. Pooled sensitivity and PPV of each VAE type for VAP detection did not exceed 50 %, while pooled specificity and NPV exceeded 80 %. Compared with VAP, pooled ORs of in-hospital death were 1.49 for VAC and 1.76 for IVAC; pooled WMDs of hospital length of stay were −4.27 days for VAC and −5.86 days for IVAC; and pooled WMDs of ventilation duration were −2.79 days for VAC and −2.89 days for IVAC. VAE surveillance missed many cases of VAP, and the population characteristics identified by the two surveillance paradigms differed. VAE surveillance does not accurately detect cases of traditional VAP in ICUs.

1 June 2021 in Translational Psychiatry
Verified
Journal Article
Open access
PDF file
LXLijuan Xiong
Lijuan Xiong
Baoliang ZhongBaoliang Zhong
Baoliang Zhong
XCXiong-Jing Cao
Xiong-Jing Cao
HXHuang-Guo Xiong
Huang-Guo Xiong
MHMing Huang
Ming Huang
YHYu Hu
Yu Hu
Suffering from COVID-19 and witnessing the suffering and deaths of patients with COVID-19 may place frontline healthcare workers (HCWs) at particularly high risk for posttraumatic stress disorder (PTSD); however, few data are available on the clinical characteristics of PTSD among frontline HCWs who survived COVID-19 (“surviving HCWs” hereafter). The present study examined the prevalence, correlates, and clinical symptoms of possible PTSD in surviving HCWs 6 months after the COVID-19 outbreak in China. A total of 291 surviving HCWs and 42 age- and gender-matched COVID-19-free frontline HCWs (control group) were recruited and administered the Chinese Essen Trauma Inventory, which was used to assess the presence of possible PTSD according to DSM-IV-TR criteria. Survivors’ clinical data and characteristics of exposure to COVID-19 were collected via self-report questionnaires. Surviving HCWs had significantly higher rates of possible PTSD than controls (19.9% vs. 4.8%, P = 0.017). Correlates of PTSD in survivors were ICU admission (OR = 8.73, P = 0.003), >10 respiratory symptoms during the most symptomatic period of COVID-19 (OR = 3.08, P = 0.006), the residual symptom of dizziness (OR = 2.43, P = 0.013), the residual symptom of difficult breathing (OR = 2.23, P = 0.027), life in danger due to COVID-19 (OR = 16.59, P = 0.006), and exposure to other traumatic events (OR = 2.94, P = 0.035). Less commonly seen PTSD symptoms in survivors were having nightmares about the event (34.5%), suddenly feeling like they were living through the event suddenly (25.9%), being unable to remember an important part of the event (32.8%), and overalertness (31.0%). Nearly one-fifth of the surviving HCWs had possible PTSD 6 months after the COVID-19 outbreak. Mental health services for this vulnerable population should include periodic screening for PTSD, expanded social support, and, when necessary, psychotherapy and psychopharmacological treatment.

15 February 2024 in Journal of Epidemiology and Global Health
Verified
Journal Article
Open access
PDF file
XCXiongjing Cao
Xiongjing Cao
HXHuangguo Xiong
Huangguo Xiong
YFYunzhou Fan
Yunzhou Fan
LXLijuan Xiong
Lijuan Xiong
Background: Accurately detecting the quantity of microorganisms in hospital purified water is of significant importance for early identification of microbial contamination and reducing the occurrence of water-borne hospital infections. The choice of detection method is a prerequisite for ensuring accurate results. Traditional Plate Count Agar (PCA) belongs to a high-nutrient medium, and there may be limitations in terms of accuracy or sensitivity in detecting microorganisms in hospital purified water. On the other hand, Reasoner’s 2A agar (R2A) has characteristics, such as low-nutrient levels, low cultivation temperature, and extended incubation time, providing advantages in promoting the growth of aquatic microorganisms. This study, through comparing the differences in total colony counts between two detection methods, aims to select the method more suitable for the growth of aquatic microorganisms, offering new practical insights for accurately detecting the total count of heterotrophic bacteria in hospital purified water. Methods: The most commonly used plate count agar (PCA) method, and the R2A agar culture were adopted to detect microorganisms and determine the total number of bacterial colonies in the water for oral diagnosis and treatment water and terminal rinse water for endoscopes in medical institutions. The two water samples were inoculated by pour plate and membrane filtration methods, respectively. Using statistical methods including Spearman and Pearson correlation, Wilcoxon signed-rank sum test, paired-Chi-square test, and linear regression, we analyze the differences and associations in the bacterial counts cultivated through two different methods. Results: In 142 specimens of the water, the median and interquartile range of the heterotrophic bacterial colony number under the R2A culture method and under the PCA culture method were 200 (Q1–Q3: 25–18,000) and 6 (Q1–Q3: 0–3700). The total number of heterotrophic bacteria colonies cultured in R2A medium for 7 days was more than that cultured in PCA medium for 2 days (P < 0.05). The linear regression results showed a relatively strong linear correlation between the number of colonies cultured by the R2A method and that cultured by the PCA method (R2 = 0.7264). The number of bacterial species detected on R2A agar medium is greater than that on PCA agar medium. Conclusion: The R2A culture method can better reflect the actual number of heterotrophic bacterial colonies in hospital purified water. After logarithmic transformation, the number of colonies cultured by the two methods showed a linear correlation.

1 February 2023 in Infection and Drug Resistance
Verified
Journal Article
Open access
PDF file
LXLijuan Xiong
Lijuan Xiong
XLXu Long
Xu Long
LNLijun Ni
Lijun Ni
LWLili Wang
Lili Wang
Yang ZhangYang Zhang
Yang Zhang
CYChunying Yang
Chunying Yang
Purpose: Matrix-assisted laser desorption-ionization-time of flight mass spectrometry (MALDI-TOF) has recently been widely used in clinical microbiology laboratories, with the advantages of being reliable, rapid, and cost-effective. Here, we reported the performance of two MALDI-TOF MS instruments, EXS3000 (Zybio, China) and Autof ms1000 (Autobio, China), which are commonly used in clinical microbiology field. Methods: A total of 209 common clinical common isolates, including 70 gram-negative bacteria strains, 58 gram-positive bacteria strains, 33 yeast strains, 15 anaerobic bacteria strains, and 33 mold strains, and 19 mycobacterial strains were tested. All strains were identified by EXS3000 (Zybio, China) and Autof ms1000 (Autobio, China). Sequence analysis of 16S rRNA or ITS regions was used to verify all strains. Results: Current study found that species-level discrimination was found to be 191 (91.39%) and 190 (90.91%) by EXS3000 and Autof ms1000, respectively. Genus-level discrimination was 205 (98.09%) by the EXS3000 and 205 (98.09%) by the Autof ms1000, respectively. The correct results at species level of the EXS3000 were 91.43% (64/70) for gram-negative bacteria, 93.1% (54/58) for gram-positive cocci, 93.94% (31/33) for yeast, 100% (15/15) for anaerobes and 81.82% (27/33) for filamentous fungi. The correct results at species level of the Autof ms1000 were 92.86% (65/70) for gram-negative bacteria, 91.38% (53/58) for gram-positive cocci, 93.94% (31/33) for yeast, 100% (15/15) for anaerobes and 78.79% (26/33) for filamentous fungi. Conclusion: Although the results show that the EXS3000 and Autof ms1000 systems are equally good choices in terms of analytical efficiency for routine procedures, the test result of EXS3000 is slightly better than Autof ms1000. It’s worth mentioning that the target plate of the EXS 3000 instrument is reusable, but the target plate of the Autof ms1000 is disposable, making the EXS3000 more effective in reducing costs.

1 December 2019 in Infection and Drug Resistance
Verified
Journal Article
Open access
PDF file
XCXu Chen
Xu Chen
KMKai Ma
Kai Ma
YXYi Xu
Yi Xu
ZXZiyu Xiao
Ziyu Xiao
LXLijuan Xiong
Lijuan Xiong
SLShijun Li
Shijun Li
Background: Enterococcus faecalis, an opportunistic bacterial pathogen, is one of the most frequently isolated bacterial species and cause of serious nosocomial infections in recent decades. A reliable and rapid assay for E. faecalis detection is significant for the diagnosis and follow-up treatment. Methods: A novel assay method, named multiple cross displacement amplification linked with nanoparticle-based lateral flow biosensor (MCDA-LFB), was applied for detecting E. faecalis strains. A set of special 10 primers was designed according to E. faecalis-specific gene Ef0027. The MCDA amplification conditions, including the target DNA concentration, reaction temperature and time, were optimized. The sensitivity and specificity of MCDA method were tested in the current study, and then, the MCDA-LFB technology was applied to detect the E. faecalis strain from clinical samples. Results: The E. faecalis specific primers were valid for the establishment of MCDA-LFB technology forthe detection of E. faecalis based on the Ef0027 gene. The MCDA amplification condition was optimized at 62°C for 35 min. The MCDA products were directly sensed and displayed with a biosensor. The full process, comprising genomic DNA template preparation (approximately 30 mins), amplification of MCDA (35 mins), and the product identification (approximately 2 mins), could be achieved in 70 mins. The MCDA technique could detect as little as 10 fg per reaction system of pure E. faecalis genomic DNA. The specificity of E. faecalis-MCDA-LFB method is 100%, with no cross-reactions to non-E. faecalis strains. Conclusion: The MCDA-LFB technique established in the present study is a reliable, simple, rapid, sensitive and specific method to assay E. faecalis and can be applied for the detection of clinical samples.