Wu-Feng Xue

Dr. Wu-Feng Xue


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2013 in IEEE Transactions on Image Processing
Verified
Journal Article
Open access
WXWu-Feng Xue
Wu-Feng Xue
LZLei Zhang
Lei Zhang
XMXuanqin Mou
Xuanqin Mou
ABAlan C. Bovik
Alan C. Bovik
It is an important task to faithfully evaluate the perceptual quality of output images in many applications, such as image compression, image restoration, and multimedia streaming. A good image quality assessment (IQA) model should not only deliver high quality prediction accuracy, but also be computationally efficient. The efficiency of IQA metrics is becoming particularly important due to the increasing proliferation of high-volume visual data in high-speed networks. We present a new effective and efficient IQA model, called gradient magnitude similarity deviation (GMSD). The image gradients are sensitive to image distortions, while different local structures in a distorted image suffer different degrees of degradations. This motivates us to explore the use of global variation of gradient based local quality map for overall image quality prediction. We find that the pixel-wise gradient magnitude similarity (GMS) between the reference and distorted images combined with a novel pooling strategy-the standard deviation of the GMS map-can predict accurately perceptual image quality. The resulting GMSD algorithm is much faster than most state-of-the-art IQA methods, and delivers highly competitive prediction accuracy. MATLAB source code of GMSD can be downloaded at http://www4.comp.polyu.edu.hk/~cslzhang/IQA/GMSD/GMSD.htm.

8 September 2014 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
WXWu-Feng Xue
Wu-Feng Xue
XMXuanqin Mou
Xuanqin Mou
LZLei Zhang
Lei Zhang
ABAlan C. Bovik
Alan C. Bovik
XFXiangchu Feng
Xiangchu Feng
Blind image quality assessment (BIQA) aims to evaluate the perceptual quality of a distorted image without information regarding its reference image. Existing BIQA models usually predict the image quality by analyzing the image statistics in some transformed domain, e.g., in the discrete cosine transform domain or wavelet domain. Though great progress has been made in recent years, BIQA is still a very challenging task due to the lack of a reference image. Considering that image local contrast features convey important structural information that is closely related to image perceptual quality, we propose a novel BIQA model that utilizes the joint statistics of two types of commonly used local contrast features: 1) the gradient magnitude (GM) map and 2) the Laplacian of Gaussian (LOG) response. We employ an adaptive procedure to jointly normalize the GM and LOG features, and show that the joint statistics of normalized GM and LOG features have desirable properties for the BIQA task. The proposed model is extensively evaluated on three large-scale benchmark databases, and shown to deliver highly competitive performance with state-of-the-art BIQA models, as well as with some well-known full reference image quality assessment models.

1 June 2013
Verified
Conference Paper
Closed access
WXWu-Feng Xue
Wu-Feng Xue
LZLei Zhang
Lei Zhang
XMXuanqin Mou
Xuanqin Mou
General purpose blind image quality assessment (BIQA) has been recently attracting significant attention in the fields of image processing, vision and machine learning. State-of-the-art BIQA methods usually learn to evaluate the image quality by regression from human subjective scores of the training samples. However, these methods need a large number of human scored images for training, and lack an explicit explanation of how the image quality is affected by image local features. An interesting question is then: can we learn for effective BIQA without using human scored images? This paper makes a good effort to answer this question. We partition the distorted images into overlapped patches, and use a percentile pooling strategy to estimate the local quality of each patch. Then a quality-aware clustering (QAC) method is proposed to learn a set of centroids on each quality level. These centroids are then used as a codebook to infer the quality of each patch in a given image, and subsequently a perceptual quality score of the whole image can be obtained. The proposed QAC based BIQA method is simple yet effective. It not only has comparable accuracy to those methods using human scored images in learning, but also has merits such as high linearity to human perception of image quality, real-time implementation and availability of image local quality map.

30 January 2013 in IEEE Signal Processing Letters
Verified
Journal Article
Closed access
XZXuande Zhang
Xuande Zhang
XFXiangchu Feng
Xiangchu Feng
WWWeiwei Wang
Weiwei Wang
WXWu-Feng Xue
Wu-Feng Xue
The objective image quality assessment aims to model the perceptual fidelity of semantic information between two images. In this letter, we assume that the semantic information of images is fully represented by edge-strength of each pixel and propose an edge-strength-similarity-based image quality metric (ESSIM). Through investigating the characteristics of the edge in images, we define the edge-strength to take both anisotropic regularity and irregularity of the edge into account. The proposed ESSIM is considerably simple, however, it can achieve slightly better performance than the state-of-the-art image quality metrics as evaluated on six subject-rated image databases.

26 May 2017 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
WXWu-Feng Xue
Wu-Feng Xue
AIAli Islam
Ali Islam
MBMousumi Bhaduri
Mousumi Bhaduri
SLShuo Li
Shuo Li
Cardiac indices estimation is of great importance during identification and diagnosis of cardiac disease in clinical routine. However, estimation of multitype cardiac indices with consistently reliable and high accuracy is still a great challenge due to the high variability of cardiac structures and the complexity of temporal dynamics in cardiac MR sequences. While efforts have been devoted into cardiac volumes estimation through feature engineering followed by a independent regression model, these methods suffer from the vulnerable feature representation and incompatible regression model. In this paper, we propose a semi-automated method for multitype cardiac indices estimation. After the manual labeling of two landmarks for ROI cropping, an integrated deep neural network Indices-Net is designed to jointly learn the representation and regression models. It comprises two tightly-coupled networks, such as a deep convolution autoencoder for cardiac image representation, and a multiple output convolution neural network for indices regression. Joint learning of the two networks effectively enhances the expressiveness of image representation with respect to cardiac indices, and the compatibility between image representation and indices regression, thus leading to accurate and reliable estimations for all the cardiac indices. When applied with five-fold cross validation on MR images of 145 subjects, Indices-Net achieves consistently low estimation error for LV wall thicknesses (1.44 ± 0.71 mm) and areas of cavity and myocardium (204 ± 133 mm 2 ). It outperforms, with significant error reductions, segmentation method (55.1% and 17.4%), and two-phase direct volume-only methods (12.7% and 14.6%) for wall thicknesses and areas, respectively. These advantages endow the proposed method a great potential in clinical cardiac function assessment.

1 April 2021 in Medical Image Analysis
Verified
Journal Article
Closed access
WXWu-Feng Xue
Wu-Feng Xue
CCChunyan Cao
Chunyan Cao
JLJie Liu
Jie Liu
YDYilian Duan
Yilian Duan
HCHaiyan Cao
Haiyan Cao
Mingxing XieMingxing Xie
Mingxing Xie