Structural deformation caused by live loads is a major concern in the design of multispan suspension bridges. Deformation characteristics of double-cable multispan suspension bridges are the focus of this paper. The authors propose a simplified mechanical model of the double-cable multispan suspension bridge for static analysis. Analytical formulas for calculating maximum deflection of the girder in a loaded span were deduced on the basis of the mechanical model. Finite-element models were established to verify formulas, and a comparison of formulas with FEM analysis revealed excellent agreement. The effects of major design parameters on the deformation of double-cable multispan suspension bridges were also studied. Research shows that the distribution of dead loads to the top and bottom cables had little effect on deformation. The sag-to-span ratio of the main cable imposed a significant effect on deformation, and structural deformation decreased with a decrement in top-cable sag or an increment...
Sliding resistance of the main cable is of the biggest concern when designing multispan suspension bridges. This paper presents a study on the layout form and sliding-resistance stability of the main cable in a double-cable multispan suspension bridge. It proposes a “top cable to bottom cable” layout, based on which analytical formulas for calculating the sliding-resistance coefficient of the double-cable have been derived. The formulas were verified by finite-element models (FEMs), and the results showed good agreement. The effects of major design parameters on the sliding resistance of the main cable were studied. Analysis shows that the top cable to bottom cable layout can effectively improve the sliding resistance of the main cable, and the bottom cable of the loaded span and the top cable of the unloaded span control the antisliding design of double cable; the sliding resistance of the main cable decreases along with an increase in the ratio of tower stiffness to cable stiffness; the influenc...
Determining the stiffness of the middle tower is a key problem in designing multispan suspension bridges. In this study, the expressions for the upper and lower limits of the middle tower stiffness of double-cable triple-tower suspension bridges were deduced by implementing the antiskid safety factor and the deflection-to-span ratio of the main cable as the control indexes in an analytical algorithm to determine the appropriate stiffness of the middle tower. The formulas obtained were verified by finite-element models, and the results showed good agreement. Furthermore, the formulas can be used to quickly select the type of middle tower for a double-cable multispan suspension bridge at the initial design phase. The value ranges of the middle tower stiffness were compared between the double-cable and conventional multispan suspension bridges, and the results showed a large difference between the upper and lower limits of the middle tower stiffness in a double-cable system; the middle tower stiffness of the double-cable system was more likely to simultaneously meet the requirements of structural deformation and skid resistance of the main cable, and the value range of the middle tower stiffness can be expanded by increasing the sag-to-span ratio of the bottom cable or decreasing the ratio of the top cable. The lower limit of the middle tower stiffness of the double-cable multispan suspension bridge is smaller than that of the conventional bridge, which allows the flexible tower to be incorporated into the design of a double-cable system.
In a multi-tower cable-stayed bridge with crossing cables, the crossing cable pre-tension forces can not only control the vertical displacement of the deck under dead load, but also affect the structural performance. This paper presents an optimization method for pre-tension forces of crossing cable multi tower cable-stayed bridge. This method uses the conic quasi-uniform B-spline curve to represent the distribution of cable pre-tension forces, and the shape of the curve is optimized by particle swarm optimization algorithm. The displacement of the tower and deck under dead load and the displacement of the deck under dead load + live load are taken as optimization objectives, and the two-objective optimization problem is solved by linear weighting method. Finally, the effectiveness of the proposed method is verified by comparing it with practical methods. The calculation results indicate that when the stress level of the cable under dead load is consistent, this method minimizes the vertical displacement of the deck under dead load and live load.
To increase the structural stiffness of multitower cable-stayed bridges, an analysis theory of crossed cable is developed, and a new-layout scheme of crossed cable for the multitower cable-stayed bridges is presented. The area ratio of the crossed cables at the same anchorage position was derived by examining their restraint stiffness to the bridge tower. Accordingly, the anchorage position of the crossed cable on the main span with a maximum restraint stiffness was examined, and an asymmetrical arrangement of the crossed cables on the main span was proposed. The finite-element models of three- and four-tower cable-stayed bridges were established. The influences of the asymmetrical arrangement of crossed cables on the deformation of the tower and girder, the stress of the bridge tower, and the dynamic characteristics of the bridge were analyzed. The results from the analysis demonstrate that the area ratio of crossed cables is equal to the ratio of the square of the cable length when their restraint stiffness is maximum. When the height–span ratio of the multitower cable-stayed bridge was between 0.2 and 0.3 and the anchorage position of the crossed cable was 0.69–0.73 times the span length from the middle tower, the restraint stiffness of the crossed cables was maximum. Under a uniform live load, the mechanical properties of asymmetrical arrangements were better than those of the symmetrical arrangement of crossed cables. When the crossed cable as adjusted to an asymmetrical arrangement for three- and four-tower cable-stayed bridges, the tower top displacement and tower bending moment were considerably reduced, and the vertical frequency of the bridge was increased. Note that the asymmetrical arrangement could considerably improve the restraint of crossed cables to the middle tower, increase the structural stiffness of the bridge, and improve the stress of the middle tower.
Insufficient structural stiffness is a key technical challenge that restricts the increase in span of multi-tower cable-stayed bridges. In order to clarify the application effect of crossing cables in long-span, multi-tower cable-stayed bridges, theoretical analysis and the finite element method were used to study the influence of the cable sag effect on the longitudinal constraint stiffness of crossing cables. The longitudinal constraint stiffness formula of the crossing cable was modified by introducing the equivalent elastic modulus to consider the cable sag effect. Based on the stiffness formula, the influence of the main span, initial stress of the crossing cable, and the ratio of the crossing cable area on its restraining effect was analyzed. The finite element model of a three-tower cable-stayed bridge with main span length of 1000 m and 1500 m is established to verify the accuracy of the formula, and the influence of the number of crossing cables and the tower height on the restraining effect of crossing cables is explored. The research results indicate that as the main span length increases, the location of maximum restraining stiffness of crossing cables moves closer to the mid span; increasing the area of crossing cables connected to the mid tower can effectively suppress the deviation of the tower. In addition, increasing the main span length will reduce the restraining effect of the crossing cables, while changes in the height of the towers do not affect the enhancement effect of the crossing cables on structural rigidity.