Sachi Furukawa

Dr. Sachi Furukawa


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
SFSachi Furukawa
Sachi Furukawa
RIRyohei Iwami
Ryohei Iwami
YKYoshihiro Kimura
Yoshihiro Kimura
The building and construction sector accounts for nearly 40% of global greenhouse gas emissions, with steel-framed buildings being a significant contributor due to high CO2 emissions during production. To mitigate this issue, integrating Cross-Laminated Timber (CLT) into structural systems has emerged as a sustainable alternative. CLT, known for its carbon sequestration properties, offers an environmentally friendly replacement for reinforced-concrete slabs, particularly when paired with steel structures to enhance material reuse and reduce lifecycle impacts. This study focuses on hybrid systems combining H-shaped steel beams and CLT floor panels connected using high-strength friction bolts. A four-point bending test, simulating a secondary beam, was conducted, demonstrating that the composite effect significantly enhances flexural stiffness and strength. Additionally, a simplified method for evaluating the flexural stiffness and yielding strength of these composite beams, based on material and joint properties, was shown to successfully evaluate the test results.

31 January 2025 in Buildings
Verified
Journal Article
Open access
PDF file
SFSachi Furukawa
Sachi Furukawa
MSMutsuki Sato
Mutsuki Sato
THToshiharu Hirose
Toshiharu Hirose
YKYoshihiro Kimura
Yoshihiro Kimura
Pile foundation failures during earthquakes can cause severe structural damage, emphasizing the importance of accurate strength evaluation. This study focuses on concrete-filled steel pipe pile heads with inner ribs, which play a crucial role in resisting compressive loads. Compression tests were conducted on specimens simulating pile heads to investigate stress transfer between the steel pipe and infill concrete. A numerical analysis model was developed using ABAQUS 6.14 and validated against experimental results, successfully reproducing load-deformation relationships and stress transfer mechanisms. Simulations extended the study by analyzing the bearing strength of the infill concrete under rib-induced pressure, with varying diameter-to-thickness ratios D/t. The results show that the compressive strength is primarily governed by the combined effects of steel pipe buckling resistance and concrete bearing resistance of a single layer of inner ribs. The proposed evaluation formula provides a lower-bound estimate of compressive strength and effectively captures key parameters influencing performance.

12 December 2023
Verified
Book Chapter
Closed access
PDF file
HMH. Mikami
H. Mikami
SFSachi Furukawa
Sachi Furukawa
TOT. Okuji
T. Okuji
KTK. Takamori
K. Takamori
TTT. Taniguchi
T. Taniguchi

12 December 2023
Verified
Book Chapter
Closed access
PDF file
SFSachi Furukawa
Sachi Furukawa
RIRyohei Iwami
Ryohei Iwami
YKYoshihiro Kimura
Yoshihiro Kimura

15 July 2025 in Solar
Verified
Journal Article
Open access
PDF file
SFSachi Furukawa
Sachi Furukawa
HMHiroki Mikami
Hiroki Mikami
TOTakehiro Okuji
Takehiro Okuji
KTKoji Takamori
Koji Takamori
This study investigates the failure behavior of aluminum solar panel mounting structures subjected to uplift pressure, with particular focus on conditions not typically considered in conventional design, specifically, foundation defects. To clarify critical failure modes and evaluate potential countermeasures, full-scale pressure loading tests were conducted. The results showed that when even a single column base was unanchored, structural failure occurred at approximately half the design wind pressure. Although reinforcement measures—such as the installation of uplift-resistant braces—increased the failure pressure to 1.5 times the design value, they also introduced the risk of undesirable failure modes, including panel detachment. Additionally, four-point bending tests of failed members and joints, combined with structural analysis of the frame, demonstrated that once the ultimate strength of each component is known, the likely failure location within the structure can be reasonably predicted. To prevent panel blow-off and progressive failure of column bases and piles, specific design considerations are proposed based on both experimental observations and numerical simulations. In particular, avoiding local buckling in members parallel to the short side of the panels is critical. Furthermore, a safety factor of approximately two should be applied to column bases and pile foundations to ensure structural integrity under unforeseen foundation conditions.