Objective: To develop reference equations for the Glittre Activities of Daily Living test (Glittre ADL-test) on the basis of anthropometric and demographic variables in apparently healthy individuals. A secondary objective was to determine the reliability of the equations in a sample of COPD patients. Methods: This was a cross-sectional study including 190 apparently healthy individuals (95 males; median age, 54.5 years [range, 42-65]; median FEV1 = 97% [range, 91-105.2]; and median FVC = 96% [range, 88.5-102]) recruited from the general community and 74 COPD patients (55 males; mean age, 65 ± 8 years; body mass index [BMI] = 25.9 ± 4.7 kg/m2; FEV1 = 36.1 ± 14.1%; and FVC = 62.7 ± 16.1%) recruited from a pulmonary rehabilitation center. Results: The mean time to complete the Glittre ADL-test was 2.84 ± 0.45 min. In the stepwise multiple linear regression analysis, age and height were selected as Glittre ADL-test performance predictors, explaining 32.1% (p < 0.01) of the total variance. Equation 1 was as follows: Glittre ADL-testpredicted = 3.049 + (0.015 × ageyears) + (−0.006 × heightcm). Equation 2 included age and BMI and explained 32.3% of the variance in the test, the equation being as follows: Glittre ADL-testpredicted = 1.558 + (0.018 × BMI) + (0.016 × ageyears). Conclusions: The reference equations for the time to complete the Glittre ADL-test were based on age, BMI, and height as independent variables and can be useful for predicting the performance of adult individuals. The predicted values appear to be reliable when applied to COPD patients.
1 December 2011 in Brazilian Journal of Physical Therapy
The Glittre ADL (TGlittre) test is a specifically designed to assess functional limitation in chronic obstructive pulmonary disease (COPD) patients. However, it is not known if it can differentiate the performance of these patients from healthy subjects. To investigate whether the Glittre ADL test is able to differentiate the functional capacity of COPD patients from that of healthy subjects and to compare the cardiorespiratory response between Glittre ADL and the six-minute walk test (6MWT). The study included 10 patients with COPD (GOLD 2 to 4) and 10 healthy subjects matched by age who performed the following: spirometry pre- and post-bronchodilator, a Glittre ADL test and two 6MWT on two consecutive days. The performance of COPD (FEV1%pred= 38.1±11.8, age=64±10 years, BMI=23.7±5.2 kg/ m²) was worse than the control group on TGlittre (5.26±2.9 min, 3.3±0.3 min, p0.05). The performance of COPD patients is worse than that of healthy subjects on the Glittre ADL test, with a greater increase in dyspnea and similar heart rates.