Weiqiang Liu

Prof. Weiqiang Liu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in World Neurosurgery
Verified
Journal Article
Closed access
HSHangkai Shen
Hangkai Shen
GFGuy R. Fogel
Guy R. Fogel
JZJia Zhu
Jia Zhu
ZLZhenhua Liao
Zhenhua Liao
WLWeiqiang Liu
Weiqiang Liu

1 April 2021 in Clinical Biomechanics
Verified
Journal Article
Closed access
HSHangkai Shen
Hangkai Shen
YCYuru Chen
Yuru Chen
ZLZhenhua Liao
Zhenhua Liao
WLWeiqiang Liu
Weiqiang Liu

17 May 2021 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
HSHangkai Shen
Hangkai Shen
GFGuy R. Fogel
Guy R. Fogel
JZJia Zhu
Jia Zhu
ZLZhenhua Liao
Zhenhua Liao
WLWeiqiang Liu
Weiqiang Liu

10 August 2022 in Orthopaedic Surgery
Verified
Journal Article
Open access
JZJia Zhu
Jia Zhu
HSHangkai Shen
Hangkai Shen
YCYangyang Cui
Yangyang Cui
GFGuy R. Fogel
Guy R. Fogel
ZLZhenhua Liao
Zhenhua Liao
WLWeiqiang Liu
Weiqiang Liu
Objective: To investigate the biomechanics of transforaminal lumbar interbody fusion (TLIF) with interspinous process device (IPD) or pedicle screw fixation under both static and vibration conditions by the finite element (FE) method.Method: A validated FE model of the L1‐5 lumbar spine was used in this study. This FE model derived from computed tomography images of a healthy female adult volunteer of appropriate age. Then the model was modified to simulate L3‐4 TLIF. Four conditions were compared: (i) intact; (ii) TLIF combined with bilateral pedicle screw fixation (BPSF); (iii) TLIF combined with U‐shaped IPD Coflex‐F (CF); and (iv) TLIF combined with unilateral pedicle screw fixation (UPSF). The intact and surgical FE models were analyzed under static and vibration loading conditions respectively. For static loading conditions, four motion modes (flexion, extension, lateral bending, and axial rotation) were simulated. For vibration loading conditions, the dynamic responses of lumbar spine under sinusoidal vertical load were simulated.Result: Under static loading conditions, compared with intact case, BPSF decreased range of motion (ROM) by 92%, 95%, 89% and 92% in flexion, extension, lateral bending and axial rotation, respectively. While CF decreased ROM by 87%, 90%, 69% and 80%, and UPSF decreased ROM by 84%, 89%, 66% and 82%, respectively. Compared with CF, UPSF increased the endplate stress by 5%–8% in flexion, 7%–10% in extension, 2%–4% in lateral bending, and decreased the endplate stress by 16%–19% in axial rotation. Compared with CF, UPSF increased the cage stress by 9% in flexion, 10% in extension, and decreased the cage stress by 3% in lateral bending, and 13% in axial rotation. BPSF decreased the stress responses of endplates and cage compared with CF and UPSF. Compared BPSF, CF decreased the facet joint force (FJF) by 6%–13%, and UPSF decreased the FJF by 4%–12%. During vibration loading conditions, compared with BPSF, CF reduced maximum values of the FJF by 16%–32%, and vibration amplitudes by 22%–35%, while UPSF reduced maximum values by 20%–40%, and vibration amplitudes by 31%–45%.Conclusion: Compared with other surgical models, BPSF increased the stability of lumbar spine, and also showed advantages in cage stress and endplate stress. CF showed advantages in IDP and FJF especially during vertical vibration, which may lead to lower risk of adjacent segment degeneration. CF may be an effective alternative to pedicle screw fixation in TLIF procedures.

12 August 2022 in Clinical Biomechanics
Verified
Journal Article
Closed access
YCYangyang Cui
Yangyang Cui
HSHangkai Shen
Hangkai Shen
YCYuru Chen
Yuru Chen
WZWei Zhang
Wei Zhang
JZJia Zhu
Jia Zhu
WLWeiqiang Liu
Weiqiang Liu

3 April 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
HSHangkai Shen
Hangkai Shen
CJChuanguang Ju
Chuanguang Ju
TGTao Gao
Tao Gao
JZJia Zhu
Jia Zhu
WLWeiqiang Liu
Weiqiang Liu
The interspinous process device (IPD) has emerged as a viable alternative for managing lumbar degenerative pathologies. Nevertheless, limited research exists regarding mechanical failure modes including device failure and spinous process fracture. This study developed a novel IPD (IPD-NEW) and systematically evaluated its biomechanical characteristics through finite element (FE) analysis and in vitro cadaveric biomechanical testing. Six human L1–L5 lumbar specimens were subjected to mechanical testing under four experimental conditions: (1) Intact spine (control); (2) L3–L4 implanted with IPD-NEW; (3) L3–L4 implanted with Wallis device; (4) L3–L4 implanted with Coflex device. Segmental range of motion (ROM) was quantified across all test conditions. A validated L1–L5 finite element model was subsequently employed to assess biomechanical responses under both static and vertical vibration loading regimes. Comparative analysis revealed that IPD-NEW demonstrated comparable segmental ROM to the Wallis device while exhibiting lower rigidity than the Coflex implant. The novel design effectively preserved physiological spinal mobility while enhancing load distribution capacity. IPD-NEW demonstrated notable reductions in facet joint forces, device stress concentrations, and spinous process loading compared to conventional implants, particularly under vibrational loading conditions. These findings suggest that IPD-NEW may mitigate risks associated with facetogenic pain, device failure, and spinous process fracture through optimized load redistribution.