Alexandra Gogola

Mrs. Alexandra Gogola

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
AGAlexandra Gogola
Alexandra Gogola
DMDavneet Singh Minhas
Davneet Singh Minhas
VVVictor L. Villemagne
Victor L. Villemagne
ACAnn D. Cohen
Ann D. Cohen
JMJames M. Mountz
James M. Mountz
BLBrian J. Lopresti
Brian J. Lopresti
Tau PET tracers exhibit varying levels of specific signal and distinct off-target binding patterns that are more diverse than amyloid PET tracers. This study compares two frequently used tau PET tracers, [18F]flortaucipir (FTP) and [18F]MK-6240, in the same subjects. METHODS: [18F]flortaucipir and [18F]MK-6240 scans were collected within two months in 15 elderly subjects varying in terms of clinical diagnosis and cognition. FreeSurfer v5.3 was applied to 3T MR images to segment Braak pathologic regions (I-VI) for PET analyses. Off-target binding was assessed in choroid plexus, meninges, and striatum. SUVR outcomes were determined over 80-100 min ([18F]flortaucipir) or 70-90 min ([18F]MK-6240) normalized to cerebellar grey matter. Blinded visual interpretation of images was performed by five raters for both medial temporal lobe (MTL) and neocortex (NEO) and an overall (majority) rating determined. RESULTS: Overall visual ratings showed complete concordance between radiotracers for both MTL and NEO. SUVR outcomes were highly correlated (r2>0.92; P << 0.001) for all Braak regions except Braak II. The dynamic range of SUVR values in target regions was approximately two-fold higher for [18F]MK-6240 compared to [18F]flortaucipir. Cerebellar SUV values were similar for [18F]MK-6240 and [18F]flortaucipir, suggesting that differences in SUVR values are driven by specific signal. Apparent off-target binding in striatum and choroid plexus was often observed with [18F]flortaucipir, and most often in meninges with [18F]MK-6240. CONCLUSION: Both [18F]MK-6240 and [18F]flortaucipir are capable of quantifying signal in a common set of brain regions that develop tau pathology in AD and perform equally well in visual interpretations. Each also shows distinct patterns of apparent off-target binding. [18F]MK-6240 showed greater dynamic range in SUVR estimates, which may be an advantage for detecting very early signal or in longitudinal studies designed to detect small interval changes.

1 October 2018 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
AGAlexandra Gogola
Alexandra Gogola
NJNing-Jiun Jan
Ning-Jiun Jan
KLKira L. Lathrop
Kira L. Lathrop
ISIan A. Sigal
Ian A. Sigal
Purpose: To test the hypothesis that human, monkey, pig, sheep, cow, and goat eyes exhibit circumferential, radial, and interweaving collagen architecture in the posterior sclera. Methods: We analyzed 1,327 cryosections from the posterior poles of 4 human, 4 monkey, 5 pig, 8 sheep, 1 goat, and 2 cow eyes. Images were acquired using polarized light microscopy and processed to obtain polar fiber orientations relative to the center of the canal. Circumferential, radial, and interweaving regions were identified and analyzed for mean fiber orientation and anisotropy and region width and thickness. Results: Every eye exhibited circumferential, radial, and interweaving fibers in consistent locations. Radial fibers extended out from near the canal into the peripapillary and peripheral sclera in the innermost sclera. Circumferential fibers were directly adjacent to the canal and most prevalent in the outermost, posterior sclera. Interweaving fibers were found throughout the sclera thickness. Across all species, median anisotropy in the radial, circumferential, and interweaving regions were 0.95, 0.96, and 0.28, respectively. Conclusions: Regions of radial, circumferential, and interweaving fibers occur in the posterior pole sclera of human, monkey, pig, sheep, cow, and goat eyes. The consistency across species in scleral architecture suggests that they are primary organizational components whose functions should be better understood.

1 June 2018 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
AGAlexandra Gogola
Alexandra Gogola
NJNing-Jiun Jan
Ning-Jiun Jan
BBBryn Brazile
Bryn Brazile
PLPo Lam
Po Lam
KLKira L. Lathrop
Kira L. Lathrop
ISIan A. Sigal
Ian A. Sigal
Purpose: Collagen is the main load-bearing component of the eye, and collagen crimp is a critical determinant of tissue mechanical behavior. We test the hypothesis that collagen crimp morphology varies over the human cornea and sclera and with age. Methods: We analyzed 42 axial whole-globe sections from 20 normal eyes of 20 human donors, ranging in age from 0.08 (1 month) to 97 years. The sections were imaged using polarized light microscopy to obtain μm-scale fiber bundle/lamellae orientation from two corneal and six scleral regions. Crimp morphology was quantified through waviness, tortuosity, and amplitude. Results: Whole-globe median waviness, tortuosity, and amplitude were 0.127 radians, 1.002, and 0.273 μm, respectively. These parameters, however, were not uniform over the globe, instead exhibiting distinct, consistent patterns. All crimp parameters decreased significantly with age, with significantly different age-related decreases between regions. The crimp morphology of the limbus changed the most drastically with age, such that it had the largest crimp in neonates, and among the smallest in the elderly. Conclusions: Age-related decreases in crimp parameters are likely one of the mechanisms underlying age-related stiffening of the sclera and cornea, potentially influencing sensitivity to IOP. Further work is needed to determine the biomechanical implications of the crimp patterns observed. The comparatively large changes in the crimp morphology of the limbus, especially in the early years of life, suggest that crimp in this region may play a role in eye development, although the exact nature of this is unclear.

1 July 2018 in Experimental Eye Research
Verified
Journal Article
Closed access
NJNing-Jiun Jan
Ning-Jiun Jan
BBBryn L. Brazile
Bryn L. Brazile
DHDanielle Hu
Danielle Hu
GGGarrett Grube
Garrett Grube
JWJacob Wallace
Jacob Wallace
ISIan A. Sigal
Ian A. Sigal

29 December 2021 in Experimental Eye Research
Verified
Journal Article
Closed access
SWSusannah Waxman
Susannah Waxman
BBBryn L. Brazile
Bryn L. Brazile
BYBin Yang
Bin Yang
PLPo-Yi Lee
Po-Yi Lee
YHYi Hua
Yi Hua
ISIan A. Sigal
Ian A. Sigal

4 September 2018 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
BBBryn L. Brazile
Bryn L. Brazile
YHYi Hua
Yi Hua
NJNing-Jiun Jan
Ning-Jiun Jan
JWJacob Wallace
Jacob Wallace
AGAlexandra Gogola
Alexandra Gogola
ISIan A. Sigal
Ian A. Sigal
Purpose: To compare the collagen microstructural crimp characteristics between thin and thick lamina cribrosa (LC) beams. Methods: Seven eyes from four sheep were fixed at 5 mm Hg IOP in 10% formalin. For each eye, one to three coronal cryosections through the LC were imaged with polarized light microscopy and analyzed to visualize the LC and determine collagen fiber microstructure. For every beam, we measured its width and three characteristics of the crimp of its collagen fibers: waviness, tortuosity, and amplitude. Linear mixed effects models were used to test whether crimp characteristics were associated with the LC beam width. Results: For each eye and over all the eyes, LC beam width was positively associated with crimp waviness and tortuosity, and negatively associated with crimp amplitude (P's < 0.0001). Thin beams, average width 13.11 μm, had average (SD) waviness, tortuosity, and amplitude of 0.27 (0.17) radians, 1.017 (0.028) and 1.88 (1.41) μm, respectively. For thick beams, average width 26.10 μm, these characteristics were 0.33 (0.18) radians, 1.025 (0.037) and 1.58 (1.36) μm, respectively. Conclusions: Our results suggest heterogeneity in LC beam mechanical properties. Thin beams were less wavy than their thicker counterparts, suggesting that thin beams may stiffen at lower IOP than thick beams. This difference may allow thin beams to support similar amounts of IOP-induced force as thicker beams, thus providing a similar level of structural support to the axons at physiologic IOP, despite the differences in width. Measurements of beam-level mechanical properties are needed to confirm these predictions.