Beta frequency oscillations originating from the primary motor cortex increase in amplitude following the initiation of voluntary movement, a process termed beta rebound. The strength of beta rebound has been reported to predict the recovery of motor function following stroke, suggesting therapeutic applications of beta rebound modulation. The present study examined the effect of 20 Hz transcranial alternating current stimulation (tACS) on the beta rebound induced by self-paced voluntary movement. Electroencephalograms (EEGs) and electromyograms (EMGs) were recorded from 16 healthy adults during voluntary movements performed before and after active or sham tACS. There was no significant change in average beta rebound after active tACS. However, the beta rebound amplitude was significantly enhanced in a subset of participants, and the magnitude of the increase across all participants was negatively correlated with the difference between individual peak beta frequency and tACS frequency. Thus, matching the stimulus frequency of tACS with individual beta frequency may facilitate therapeutic enhancement for motor rehabilitation.
The Go/NoGo task requires attention and sensory processing to distinguish a motor action cue or ‘Go stimulus’ from a ‘NoGo stimulus’ requiring no action, as well as motor preparation for a rapid Go stimulus response. The neural activity mediating these response phases can be examined non-invasively by measuring specific event-related brain potentials (ERPs) using electroencephalography. However, it is critical to determine how different task conditions, such as the relationship between attention site and movement site, influence ERPs and task performance. In this study, we compared attention-associated ERP components N140 and P300, the performance metrics reaction time (RT) and accuracy (%Error) and movement-related cortical potentials (MRCPs) between Go/NoGo task trials in which attention target and movement site were the same (right index finger movement in response to right index finger stimulation) or different (right index finger movement in response to fifth finger stimulation). In other Count trials, participants kept a running count of target stimuli presented but did not initiate a motor response. The N140 amplitudes at electrode site Cz were significantly larger in Movement trials than in Count trials regardless of the stimulation site–movement site condition. In contrast, the P300 amplitude at Cz was significantly smaller in Movement trials than in Count trials. The temporal windows of N140 and P300 overlapped with the MRCP. This superposition may influence N140 and P300 through summation, possibly independent of changes in attentional allocation.
Background/Objectives: Unilateral hand movements alter the excitability of the ipsilateral primary motor cortex (ipsi-M1) and contralateral spinal motoneurons. Although this excitability increases during complex, high muscle-activity movements, few studies have examined the excitability of ipsi-M1 and contralateral spinal motoneurons during complex movements while accounting for muscle activity. This study investigated the excitability of ipsi-M1 and contralateral spinal motoneurons during complex and simple movement tasks with comparable muscle activity between the two tasks. Methods: Nineteen healthy adult volunteers participated in this study. The ball rotation task was set as the complex movement task (BR condition), and the grasping task was set as the simple movement task (grasp condition), with peak muscle activity values comparable between the tasks. Motor-evoked potentials (MEPs) and F-waves were recorded from the abductor pollicis brevis muscle contralateral to the movement during task execution. The excitability parameters of ipsi-M1 and contralateral spinal motoneurons were calculated by dividing the MEP, F-wave persistence, and F/M amplitude values recorded in each condition by the corresponding values recorded at rest. These parameters were compared across the rest, BR, and grasp conditions. Results: All the excitability parameters of ipsi-M1 and contralateral spinal motoneurons increased during both the BR and grasp conditions compared with the rest condition but did not differ significantly between the BR and grasp conditions. Conclusions: The excitability of ipsi-M1 and contralateral spinal motoneurons was strongly influenced by the amount of muscle activity but not by the complexity of the movement.
Beta-band event-related synchronization (βERS) in the contralateral sensorimotor cortex is induced by voluntary movement and somatosensory input, suggesting its deep involvement in afferent information processing, but the precise generative mechanisms require further investigation. This study examined the contributions of joint movement to βERS following self-paced voluntary movement. The βERS was recorded from 15 healthy adults while performing a task involving contraction of the right extensor indicis proprius muscle with and without metacarpophalangeal joint movement using electroencephalography (EEG) and magnetoencephalography (MEG). In both joint movement and non-movement conditions, βERS amplitude was significantly greater than baseline, whether measured by EEG or MEG, but was significantly greater in the joint movement condition. In addition, βERS amplitude was significantly greater when measured by MEG. These findings suggest that, in addition to changes in muscle tension, afferent inputs associated with changes in joint position may contribute to the increase in βERS amplitude. The stronger βERS detected by MEG further suggests that neuronal activity in cortical sulci is a major contributor to βERS generation. This study provides new insights into the physiological mechanisms underlying βERS.