Adey Feleke Desta

Dr. Adey Feleke Desta

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2013 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
CKChristin Koch
Christin Koch
SGSusanne Günther
Susanne Günther
ADAdey Feleke Desta
Adey Feleke Desta
THThomas Hübschmann
Thomas Hübschmann
SMSusann Müller
Susann Müller

26 December 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ADAdey Feleke Desta
Adey Feleke Desta
FAFassil Assefa
Fassil Assefa
SLSeyoum Leta
Seyoum Leta
FSFrancesca Stomeo
Francesca Stomeo
MWMark Wamalwa
Mark Wamalwa
DADjikeng Appolinaire
Djikeng Appolinaire
A culture-independent approach was used to elucidate the microbial diversity and structure in the anaerobic-aerobic reactors integrated with a constructed wetland for the treatment of tannery wastewater in Modjo town, Ethiopia. The system has been running with removal efficiencies ranging from 94%–96% for COD, 91%–100% for SO42- and S2-, 92%–94% for BOD, 56%–82% for total Nitrogen and 2%–90% for NH3-N. 16S rRNA gene clone libraries were constructed and microbial community assemblies were determined by analysis of a total of 801 unique clone sequences from all the sites. Operational Taxonomic Unit (OTU) - based analysis of the sequences revealed highly diverse communities in each of the reactors and the constructed wetland. A total of 32 phylotypes were identified with the dominant members affiliated to Clostridia (33%), Betaproteobacteria (10%), Bacteroidia (10%), Deltaproteobacteria (9%) and Gammaproteobacteria (6%). Sequences affiliated to the class Clostridia were the most abundant across all sites. The 801 sequences were assigned to 255 OTUs, of which 3 OTUs were shared among the clone libraries from all sites. The shared OTUs comprised 80 sequences belonging to Clostridiales Family XIII Incertae Sedis, Bacteroidetes and unclassified bacterial group. Significantly different communities were harbored by the anaerobic, aerobic and rhizosphere sites of the constructed wetland. Numerous representative genera of the dominant bacterial classes obtained from the different sample sites of the integrated system have been implicated in the removal of various carbon- containing pollutants of natural and synthetic origins. To our knowledge, this is the first report of microbial community structure in tannery wastewater treatment plant from Ethiopia.

1 May 2021 in Heliyon
Verified
Journal Article
Open access
BDBitew K. Dessie
Bitew K. Dessie
SGSirak Robele Gari
Sirak Robele Gari
AMAdane Mihret
Adane Mihret
ADAdey Feleke Desta
Adey Feleke Desta
BMBewketu Mehari
Bewketu Mehari
Water is an essential component of all living things on earth and the contamination of water by heavy metals can cause detrimental health effects. This study aimed to determine the health risk posed by trace elements (Fe, Zn, Cu, Mn, Ni, Cr, Cd, Co, Pb, and As) present in the drinking water supplies of Gullele and Akaki-Kality Sub-Cities, upstream and downstream parts of Addis Ababa, respectively. The concentrations of the potentially toxic trace elements in the water samples were determined using inductively coupled plasma optical emission spectroscopy (ICP-OES). The highest concentration of the heavy metals was observed for Iron. Cadmium and cobalt were not detected in any of the tap water samples. Samples from Gullele contained higher levels of Fe and Mn, 220.3 ± 0.17 and 19.78 ± 0.08 μg/L, respectively compared to Akaki-Kality, 38.87 ± 0.14 and 2.08 ± 0.01 μg/L, respectively. Conversely, tap water from Akaki-Kality contained significantly higher levels of As than that from Gullele. Additionally, Cr and Ni were detected only in samples from Akaki-Kality, which might be due to the various industries in the area. The highest incremental lifetime cancer risk was found for arsenic, with values for children and adults in Akaki-Kality 2.50 × 10−4 and 4.50 × 10−4, respectively. Likewise, in Gullele Sub-City, it was 5.00 × 10−5 and 1.00 × 10−4 for adults and children, respectively. The results indicate that carcinogenic risk occurrence is probable from As in both studied areas.

9 August 2019 in Antimicrobial Resistance & Infection Control
Verified
Journal Article
Open access
PDF file
HTHemen Tesfaye
Hemen Tesfaye
HGHaile Alemayehu Gezahegn
Haile Alemayehu Gezahegn
ADAdey Feleke Desta
Adey Feleke Desta
TETadesse Eguale
Tadesse Eguale
Evaluation of antimicrobial susceptibility profile of various bacterial pathogens in the health facilities, abattoirs and related environment is important to assess potential risk of dissemination of resistant pathogens to the environment. There is limited information about antimicrobial susceptibility profile of common Enterobacteriaceae in waste water samples from hospitals, abattoirs and the downstream water bodies in Addis Ababa. The present study assessed antimicrobial susceptibility of bacteria belonging to the family Enterobacteriaceae isolated from wastewater samples (WWS) of two hospitals: Tikur Anbessa Specialized Hospital (TASH) and Minilik II hospital, a wastewater treatment plant (WWTP) and an abattoir, and downstream rivers in Addis Ababa. A total of 54 bacterial isolates belonging to 6 species were identified: E.coli (32%), Salmonella 23%), Klebsiella pneumonia (15%), Enterobacter aerogenes (11%), Citrobacter (7%), Klebsiella oxytoca (6%) and Enterobacter cloacae (6%), respectively. Two strains of Citrobacter spp. isolated from TASH wastewater sample (WWS) were resistant to all 12 antimicrobials tested whereas an E. coli isolate from the same source was resistant to 11 antimicrobials. All isolates were resistant to 2 or more antimicrobials tested. Multi-drug resistance (MDR) to several antimicrobials was recorded, particularly in isolates obtained from hospital WWS and it was more common in Citrobacter and E. coli isolates. Extended spectrum betalactamase (ESBL) production was detected in 27.3% of MDR isolates, all of them obtained from hospital effluents whereas none of the isolates were carbapenemase producers. The present study revealed that Enterobacteriaceae in wastewater from hospitals, abattoir and downstream water bodies are resistant to commonly used antimicrobials. Hospital effluents contained more of MDR bacteria, posing significant public health threat through dissemination to the downstream water bodies.

1 January 2022 in Comparative Immunology, Microbiology and Infectious Diseases
Verified
Journal Article
Closed access
GGGebreab Teklebirhan Gessew
Gebreab Teklebirhan Gessew
ADAdey Feleke Desta
Adey Feleke Desta
EAEtsehiwot Adamu
Etsehiwot Adamu

31 May 2020 in Water Environment Research
Verified
Journal Article
Open access
PDF file
TATesfaye Admassu Abate
Tesfaye Admassu Abate
ADAdey Feleke Desta
Adey Feleke Desta
NLNancy G. Love
Nancy G. Love
Tanneries are an important industrial sector in Ethiopia; consequently, gaps in wastewater treatment process performance need to be identified as the country increases its emphasis on compliance. A case study was conducted to evaluate physicochemical and microbial water quality at a tannery near Addis Ababa. The treatment process was designed for the following: sulfide oxidation; biological oxygen demand reduction; and chromium removal. While some of Ethiopia's standards for industrial wastewater treatment were met through treatment, effluent COD, sulfide, total nitrogen, and total chromium guidelines were not. 16S rRNA gene analysis was used to evaluate the microbial community composition across the treatment train. The results show that common ruminant phyla were dominant throughout, with Firmicutes and Bacteroidetes comprising 77% to 82% relative abundance. The Firmicutes Clostridium increased consistently in relative abundance with treatment, comprising 39% to 61% of the total bacterial community in the effluent. Improved treatment is needed to meet environmental and public health goals.Practitioner Points: Case Study of tannery wastewater treatment in Ethiopia shows ineffective treatment of chemical pollutants. Microbiological pollutants from tannery wastewater systems can introduce agents of importance to public health The microbiological composition of tannery influent, mixed liquor and effluent contains mostly four bacterial phyla lead by Firmicutes. Most pathogenic bacterial genera found in the tannery wastewater treatment system became a decreasing percentage of the total population. Clostridium comprises up to 61% of the effluent bacterial population and deserves further evaluation to better understand the consequences of its dominance.