The integration of photovoltaic (PV) power generation systems has significantly increased the complexity of voltage distribution in power grids, making it challenging for conventional Load Ratio Control Transformers (LRTs) to manage voltage fluctuations caused by weather-dependent PV output variations. Power Conditioning Systems (PCSs) interconnected with PV installations are increasingly considered for voltage control to address these challenges. This study proposes a Machine Learning (ML)-based control method for sub-transmission grids, integrating long-term LRT tap-changing with short-term reactive power control of PCSs. The approach estimates the voltage at each grid node using a Deep Neural Network (DNN) that processes measurable substation data. Based on these estimated voltages, the method determines optimal LRT tap positions and PCS reactive power outputs using Deep Reinforcement Learning (DRL). This enables real-time voltage monitoring and control using only substation measurements, even in grids without extensive sensor installations, ensuring all node voltages remain within specified limits. To improve the model’s transparency, Shapley Additive Explanation (SHAP), an Explainable AI (XAI) technique, is applied to the DRL model. SHAP enhances interpretability and confirms the effectiveness of the proposed method. Numerical simulations further validate its performance, demonstrating its potential for effective voltage management in modern power grids.
The rapid integration of renewable energy sources, such as photovoltaic power systems, has reduced the necessary for synchronous generators, which traditionally contributed to grid stability during disturbances. This shift has led to a decrease in reactive power reserves (RPRs), raising concerns about voltage stability. Real-time monitoring of voltage stability is crucial for transmission system operators to implement timely corrective actions. However, conventional methods, such as continuation power flow calculations, are computationally intensive and unsuitable for large-scale power systems. Machine learning techniques using data from phasor measurement units have been proposed to estimate voltage stability. However, these methods do not consider changes in generator operating conditions and fluctuating RPRs. As renewable energy generation increases, the operating conditions of generators vary, which leads to significant changes in system RPRs and voltage stability. In this paper, a voltage stability margin is proposed using regression trees with RPRs varying based on generator operation conditions. Simulations based on the IEEE 9-bus system demonstrate that the proposed approach provides an accurate and efficient voltage stability estimation.