Andrey D Andreev

Dr. Andrey D Andreev

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2022 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
KIKhandakar Nusrat Islam
Khandakar Nusrat Islam
LLL. D. Ludeking
L. D. Ludeking
AAAndrey D Andreev
Andrey D Andreev
SPSalvador Portillo
Salvador Portillo
AEAhmed M. N. Elfrgani
Ahmed M. N. Elfrgani
ESEdl Schamiloglu
Edl Schamiloglu
The traveling wave tube (TWT) has been a reliable conventional vacuum electron device (CVED) since the 1940s. Researchers, beginning in the late 1980s, extended the TWT to the relativistic electron beam regime to generate 100- $\text{s}\cdot $ MW power in the ${X}$ -band. Since the mid-1990s, there has been little advancement in the field. Recently, the linear theory of a multistream TWT was published, which showed superexponential amplification properties. This article describes a novel technique for producing multiple electron beams with an energy difference of about 6%–27% with comparable currents from a single cathode at a single potential for a multistream TWT. We present a new model of two nested cathodes where two annular electron beams are generated and propagated in a smooth cylindrical pipe that emerged into a strong magnetic field. The two nested cathodes are magnetically insulated coaxial diodes (MICDs). The simulation results are obtained using the MAGIC particle-in-cell (PIC) code for the experimental vacuum diode geometry of the SINUS-6 high-current electron beam accelerator at The University of New Mexico. Results are obtained, which are then: 1) compared with earlier experimental results for a single beam; 2) study the current–voltage ( ${I}$ – ${V}$ ) characteristics of two electron beams powered by a single cathode at a single potential immersed in a strong magnetic field; and 3) show 6%–27% energy differences with comparable currents between two beams. This technique is viable for pulsed power-driven, relativistic electron beams for a relativistic multistream TWT.

27 July 2022 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
AAAndrey D Andreev
Andrey D Andreev
ESEdl Schamiloglu
Edl Schamiloglu
BNBrendan E. Nunan
Brendan E. Nunan
STSean M. Torrez
Sean M. Torrez
Standard operation of a conventional microwave oven 2.45-GHz “cooker” magnetron with 4.0–4.3 kV of pulsed applied voltages at 0.17–0.19-T magnetic fields results in generation of pulsed microwave power 1.8–2.8 kW, which is recalculated to an average microwave power 0.9–1.9 kW when the “cooker” magnetron operates with 50% duty cycle while driven by a “rectified” ac voltage from the wall-plug. It has been shown in many experimental studies of “cold-start” operation of a standard ten-vane 2.45-GHz “cooker” magnetron that it readily sustains, when properly conditioned, up to ~10-kV dc and up to ~14 kV of peak-to-peak ac applied voltage with just a few microamphere cold (field emission) leakage (anode) current. The latter suggests that a standard 2.45-GHz “cooker” magnetron may successfully operate in the desired, lowest $\pi $ -mode with much more output microwave power at even higher magnetic fields when driven by up to ~10 kV of dc or quasi-dc appropriate, synchronous applied voltage. Results of improved concurrent electromagnetic particle-in-cell (ICEPIC) simulations of magnetron operation at different magnetic fields with synchronous applied voltages show that, for example, with 8.0-kV applied voltage at 0.35-T magnetic field, the 2.45-GHz “cooker” magnetron is able to generate up to 6.0 kW of pulsed microwave power with an anode current of ~0.9 A.

6 September 2024 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
OBOleg Belozerov
Oleg Belozerov
GLGennadii Liziakin
Gennadii Liziakin
JLJohn Leopold
John Leopold
AAAndrey D Andreev
Andrey D Andreev
YHY. Hadas
Y. Hadas
Yakov KrasikYakov Krasik
Yakov Krasik
A relativistic magnetron (RM) with diffraction output, modified from the original Kovalev, Fuks X -band magnetron (MDO) presented more than 50 years ago, has been designed and studied experimentally using pulse generators with voltage amplitudes $\le$ 300 kV and pulse duration $\le$ 200 ns. X -band magnetrons are naturally small devices, and for high voltages, microwave pulse shortening occurs because of cathode explosive emission plasma expansion. A split cathode can potentially solve this problem, but in this research, the MDO with split cathode experienced pulse shortening as well. It is suggested based on preliminary results of simulations using the MAGIC particle-in-cell (PIC) code that the reason for this is that this magnetron needs optimization by simulations that were not available originally.

1 January 2010 in Journal of Microwave Power and Electromagnetic Energy
Verified
Journal Article
Closed access
AAAndrey D Andreev
Andrey D Andreev
KHKyle J. Hendricks
Kyle J. Hendricks
Modern CW industrial heating magnetrons are capable for producing as high as 300 kW of continuous-wave microwave power at frequencies around 900 MHz and are sold commercially [Wynn et al., 2004]. However, to utilize these magnetrons in some specific research and scientific applications being of interest for the Air Force, the necessary adaptation and redesign are required. It means that the detailed knowledge of principles of their operation and full understanding of how the changes of the design parameters affect their operational characteristics are necessary. We have developed and tested computer model of a 10-vane highpower strapped magnetron, which geometrical dimensions and design parameters are close to those of the California Tube Laboratory’s commercially produced CWM-75/100L tube. The computer model is built by using the 3-D Improved Concurrent Electromagnetic Particle-in-Cell (ICEPIC) code. Simulations of the strapped magnetron operation are performed and the following operational characteristics are obtained during the simulation: frequency and mode of magnetron oscillations, output microwave power and efficiency of magnetron operation, anode current and anode-cathode voltage dynamics. The developed computer model of a non-relativistic high-power strapped magnetron may be used by the industrial magnetron community for designing following generations of the CW industrial heating high-power magnetrons.

7 October 2021 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
AAAndrey D Andreev
Andrey D Andreev
STSean M. Torrez
Sean M. Torrez
BNBrendan E. Nunan
Brendan E. Nunan
ESEdl Schamiloglu
Edl Schamiloglu
Particle-in-cell (PIC) simulations of a microwave oven free-running 2.45 GHz “cooker” ten-vane magnetron operating with a “cold” explosive-emission cathode in a uniform axial magnetic field are performed with two computer codes, improved concurrent electromagnetic PIC (ICEPIC), and CST Particle Studio (CST-PS). PIC simulations are done to compare results obtained by these two codes to each other and, in such a way, identify all possible advantages and disadvantages of each code performance as a reliable tool allowing to predict all important characteristics of the magnetron operation. Results of the PIC simulations show that the range of applied voltages within which the magnetron is able to operate in the $\pi $ -mode at an external uniform axial magnetic field 0.19 T is much broader as it is predicted by the CST-PS code, from 4.00 to 4.70 kV, than as it predicted by the ICEPIC code, from 3.90 to 4.10 kV. It is also shown that while the magnetron startup time gradually decreases, as it is predicted by the ICEPIC code, from about 700 ns (3.90 kV) to about 100 ns (4.20 kV) with the applied voltage increase, it initially chaotically varies, as it is predicted by the CST-PS code, between about 1000 ns (4.03 kV) and about 300 ns (4.01 kV) and only then gradually decreases down to 10–20 ns (4.40–4.60 kV) with the applied voltage increase. Additional PIC simulation with MAGIC or VORPAL codes would be interesting to perform as well to compare the obtained with these codes simulation results with results described in this article.

1 August 2025 in Physics of Plasmas
Verified
Journal Article
Open access
JLJohn Leopold
John Leopold
YBYury P. Bliokh
Yury P. Bliokh
OBOleg Belozerov
Oleg Belozerov
YHYoav Hadas
Yoav Hadas
EMElhanan Magid
Elhanan Magid
Yakov KrasikYakov Krasik
Yakov Krasik
Results of Particle in Cell simulations of an optimized design of a diffraction output relativistic A8 magnetron operating as a high power microwave (HPM) source in X-band (8.77 GHz) are presented. In addition to the very high efficiency of ∼80%, this design reveals a unique property, that is, for magnetic fields significantly exceeding the Hull cutoff condition, a quasiperiodic train of HPM pulses appears with instantaneous peak power above the steady state input power amplitude. This phenomenon is described, analyzed, and explained.