Emerging flexible electronic devices differ widely in terms of material, shape, scale, and structure. The conventional solid‐contact stamp transfer printing method easily causes cracks and interfacial delamination in large‐area, intricately‐patterned multilayered devices. Liquid film transfer printing (LTP) is presented as a strategy to obtain flexible devices with a high yield ratio regardless of the device material, scale, shape, and structure. In this technique, the liquid film is used to hydrolyze and break the chemical bonds between the film and silicon wafer substrate. Thus, there is less stress on the device during the transfer process. In addition, the buoyancy and surface tension of the liquid film help the flexible device to unroll itself on the liquid surface. In the experiments, flexible devices of different types and with extreme properties consistently achieved a transfer printing yield ratio of 98.57%. The sensitivity of temperature sensor change before and after LTP is less than 2%. The real‐time and visualized comparisons of the stress distribution and evolution during LTP and solid‐contact methods demonstrated that the LTP maximum strain is 70% smaller than the latter method. Thus, LTP has great potential for sophisticated and system‐level flexible device transfer printing and integration.
Atrial fibrillation leads to severe diseases such as heart failure and strokes. While catheter ablation is prevalent for the treatment, existing techniques hardly can achieve both tissue selectivity and ablation uniformity. Here, we propose a bioinspired strategy for balloon-based pulsed field ablation (PFA) systems based on “flounder” electrodes. Inspired by a flounder skeleton and citrus peels, the microfabricated electrodes are ultrathin, stretchable, and have a scattered configuration, withstanding large balloon deformation (87% compression), high voltage (1200 volts), and owning exceptional tissue conformability (720° twists). Mechanical-electrical coupled stimulation optimizes balloon electrodes with hemispherical electric field uniformity. A water lily–inspired transfer printing method enables one-step integration of multielectrodes with the balloon. A comprehensive PFA system is complemented, achieving ablation depths of 3.8 millimeters (potato), 3.1 millimeters (rabbit), and 2.3 millimeters (swine) with good uniformity and electrophysiological isolation. These results shed light on the quantitative design of PFA systems, with high potential for more precise, safe, and effective catheter ablation therapies.
12 December 2024 in IEEE Transactions on Biomedical Engineering
Objective: Hemodynamic pressure (HP) monitoring is critical for managing cardiovascular diseases. Clinical Doppler echocardiography and invasive catheter monitoring cannot realize remote continuous monitoring in daily life. Current implantable wireless equipment depends on custom chips or indirect sensing, presenting challenges in cost-effective and precise applications. Here, we present systematic design strategies for implantable, wireless, and battery-free capsule-like HP monitoring under near and middle-distance circumstances. Methods: The systems were composed of completely non-customized devices, with extremely compact volumes (< 0.4 cm³). Near-distance monitoring utilized Near Field Communication with a piezoresistive sensor and foldable circuit designs. Middle-distance monitoring employed dual-winding antennas based on magnetic resonance (∼600 kHz) and Bluetooth. The power feedback circuit was optimized through human model electromagnetic simulations. Validation involved in vitro and in vivo experiments. Results: Near-distance system achieved 0.35 mmHg omnidirectional pressure accuracy under 5 mm tissue shielding. Middle-distance system attained the longest wireless power transfer distance (7.5 cm) via electromagnetic fields, supporting a capacitive sensor with 0.4 mmHg accuracy. In vitro tests in artificial tissue demonstrated for stable data/energy transfer, accommodating axial misalignments up to ±45°. In vivo experiments on the beagle demonstrated real-time, wireless monitoring of left-atrial pressure, whose rhythm synchronized with electrocardiograph recordings. The interatrial septum interventional installation was also validated. Conclusion: The wireless and implantable capsules enables near and middle-distance hemodynamic pressure monitoring, even in dynamic swinging intracardiac situations. and has been validated in animal experiments. Significance: The designs provide a universal method for in vivo fully-implantable pressure monitor development.