VAISHALI HANUMNAT KAMBLE

Dr. VAISHALI HANUMNAT KAMBLE


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2025 in Processes
Verified
Journal Article
Open access
PDF file
MDManisha Prasad Dale
Manisha Prasad Dale
VKVAISHALI HANUMNAT KAMBLE
VAISHALI HANUMNAT KAMBLE
RDRakesh Bapu Dhumale
Rakesh Bapu Dhumale
ANAziz Nanthaamornphong
Aziz Nanthaamornphong
Fault diagnosis in power converters is essential for keeping electrical systems stable, efficient and long-lasting. Park’s Vector Transform, discrete wavelet transform, Artificial Neural Network, Fuzzy Logic and other methods are used to diagnose faults in the power converter in both single and multiple open switch situations. These methods are implemented on the digital signal processor or controller, which needs additional hardware and consumes more processing time. This paper presents a hardware-based open switch fault diagnostic method in a 3ϕ voltage source inverter to minimize fault diagnosis time and cost. An innovative hardware-based approach that utilizes a single neuron for open switch fault diagnosis in 3ϕ voltage source inverters was successfully implemented without using a digital signal processor or controller. A gradient descent algorithm calculates the weight and bias values of a single processing neuron. Furthermore, a high-speed multiplier and adder circuit seamlessly integrate with the single processing neuron, enabling rapid real-time fault diagnosis. This method is capable of diagnosing single and multiple switch open circuit faults in switching devices under variable load conditions at different frequencies. The proposed system ensures good effectiveness and resistivity, detecting faults in less than one cycle with low implementation effort and no tuning or threshold dependence. It achieves 98% accuracy, 96% precision and 95% recall, with a 2% false positive rate. Unlike traditional methods, it eliminates DSP/controller dependency by using a single neuron-based processing circuit, reducing cost and improving real-time fault diagnosis in three-phase voltage source inverters.

28 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
MDManisha Prasad Dale
Manisha Prasad Dale
VKVAISHALI HANUMNAT KAMBLE
VAISHALI HANUMNAT KAMBLE
RDRakesh Bapu Dhumale
Rakesh Bapu Dhumale
ANAziz Nanthaamornphong
Aziz Nanthaamornphong
Park's Vector Transform, Discrete Wavelet Transform, Artificial Neural Network, Fuzzy Logic, and other methods are used to diagnose faults in the power converter in both single and multiple open switch situations. These methods are implemented on the digital signal processor or controller, which needs additional hardware and consumes more processing time. This paper presents a hardware-based open switch fault diagnostic method in a three-phase voltage source inverter to minimize fault diagnosis time and cost. An innovative hardware-based approach that utilizes a single neuron for open switch fault diagnosis in three-phase voltage source inverters has been successfully implemented without using digital signal processor or controller. A gradient descent algorithm calculates the weight and bias values of a single processing neuron. Furthermore, a high-speed multiplier and adder circuit seamlessly integrate with the single processing neuron, enabling rapid real-time fault diagnosis. This method is capable of diagnosing single and multiple switches open circuit faults in switching devices under variable load conditions at different frequencies. The results are presented for different combinations of single and multiple open switch faults under variable load conditions at different frequencies. Compared to existing algorithms, the proposed approach significantly accelerates computation while maintaining uncompromised accuracy and stability in fault diagnostics, even under dynamic load conditions in permanent magnet synchronous motor drives. The combination of a hardware-based solution, single neuron architecture, real-time gradient descent adaptation, and rapid fault diagnosis makes this method very innovative and impactful for fault diagnostics.

16 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
VKVAISHALI HANUMNAT KAMBLE
VAISHALI HANUMNAT KAMBLE
MDManisha Prasad Dale
Manisha Prasad Dale
RDRakesh Bapu Dhumale
Rakesh Bapu Dhumale
ANAziz Nanthaamornphong
Aziz Nanthaamornphong
Traditional proportional–integral–derivative (PID) controllers are often utilized in industrial control applications due to their simplicity and ease of implementation. This study presents a novel control strategy that integrates the Groupers and Moray Eels Optimization (GMEO) algorithm with a Dual-Stream Multi-Dependency Graph Neural Network (DMGNN) to optimize PID controller parameters. The approach addresses key challenges such as system nonlinearity, dynamic adaptation to fluctuating conditions, and maintaining robust performance. In the proposed framework, the GMEO technique is employed to optimize the PID gain values, while the DMGNN model forecasts system behavior and enables localized adjustments to the PID parameters based on feedback. This dynamic tuning mechanism enables the controller to adapt effectively to changes in input voltage and load variations, thereby enhancing system accuracy, responsiveness, and overall performance. The proposed strategy is assessed and contrasted with existing strategies on the MATLAB platform. The proposed system achieves a significantly reduced settling time of 100 ms, ensuring rapid response and stability under varying load conditions. Additionally, it minimizes overshoot to 1.5% and reduces the steady-state error to just 0.005 V, demonstrating superior accuracy and efficiency compared to existing methods. These improvements demonstrate the system’s ability to deliver optimal performance while effectively adapting to dynamic environments, showcasing its superiority over existing techniques.

12 March 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
VKVAISHALI HANUMNAT KAMBLE
VAISHALI HANUMNAT KAMBLE
MDManisha Prasad Dale
Manisha Prasad Dale
RDRakesh Bapu Dhumale
Rakesh Bapu Dhumale
ANAziz Nanthaamornphong
Aziz Nanthaamornphong
Traditional Proportional Integral and Derivative (PID) controllers are often utilised in industrial control applications due to their simplicity and ease of implementation. However, their performance can be limited in complex, nonlinear, time-delayed systems, as well as in noisy feedback loops. This study introduces Groupers and Moray Eels Optimization (GMEO) with Dual-Stream Multi-Dependency Graph neural network (DMGNN) to optimize PID controller parameters addressing main challenges like nonlinearity, dynamic adaptation to changing conditions, and robust performance under variable operating conditions. The proposed system combines the GMEO algorithm to optimize the PID gains and the DMGNN model to predict and locally adjust these parameters, ensuring improved accuracy and responsiveness. By dynamically tuning the PID parameters based on current system conditions, the system adapts to varying input voltages and load changes, optimizing application performance. The proposed strategy is assessed and contrasted with existing strategies on the MATLAB platform. The proposed system achieves a significantly reduced settling time of 100 ms, ensuring rapid response and stability under varying load conditions. Additionally, it minimizes overshoot to 1.5% and reduces the steady-state error to just 0.005V, demonstrating superior accuracy and efficiency compared to existing methods. These improvements demonstrate the system’s ability to deliver optimal performance while effectively adapting to dynamic environments, showcasing its superiority over existing techniques.