Jennifer Yentes

Dr. Jennifer Yentes

Department of Kinesiology & Sport Management, Texas A&M University, College Station, TX 77843, USA
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2012 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JYJennifer Yentes
Jennifer Yentes
NHNathaniel Hunt
Nathaniel Hunt
KSKendra K. Schmid
Kendra K. Schmid
JKJeffrey P. Kaipust
Jeffrey P. Kaipust
DMDenise McGrath
Denise McGrath
NSNicholas Stergiou
Nicholas Stergiou

1 August 2012 in Neuroscience Letters
Verified
Journal Article
Closed access
JHJessie M. Huisinga
Jessie M. Huisinga
JYJennifer Yentes
Jennifer Yentes
MFMary L. Filipi
Mary L. Filipi
NSNicholas Stergiou
Nicholas Stergiou

9 February 2021 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JYJennifer Yentes
Jennifer Yentes
PRPeter C. Raffalt
Peter C. Raffalt

5 October 2018 in Entropy
Verified
Journal Article
Open access
PDF file
JMJohn McCamley
John McCamley
WDWilliam Denton
William Denton
AAAndrew Arnold
Andrew Arnold
PRPeter C. Raffalt
Peter C. Raffalt
JYJennifer Yentes
Jennifer Yentes
Sample entropy (SE) has relative consistency using biologically-derived, discrete data >500 data points. For certain populations, collecting this quantity is not feasible and continuous data has been used. The effect of using continuous versus discrete data on SE is unknown, nor are the relative effects of sampling rate and input parameters m (comparison vector length) and r (tolerance). Eleven subjects walked for 10-minutes and continuous joint angles (480 Hz) were calculated for each lower-extremity joint. Data were downsampled (240, 120, 60 Hz) and discrete range-of-motion was calculated. SE was quantified for angles and range-of-motion at all sampling rates and multiple combinations of parameters. A differential relationship between joints was observed between range-of-motion and joint angles. Range-of-motion SE showed no difference; whereas, joint angle SE significantly decreased from ankle to knee to hip. To confirm findings from biological data, continuous signals with manipulations to frequency, amplitude, and both were generated and underwent similar analysis to the biological data. In general, changes to m, r, and sampling rate had a greater effect on continuous compared to discrete data. Discrete data was robust to sampling rate and m. It is recommended that different data types not be compared and discrete data be used for SE.

1 February 2018 in Gait & Posture
Verified
Journal Article
Closed access
JYJennifer Yentes
Jennifer Yentes
WDWilliam Denton
William Denton
JMJohn McCamley
John McCamley
PRPeter C. Raffalt
Peter C. Raffalt
KSKendra K. Schmid
Kendra K. Schmid