Shanghai Synchrotron Radiation Facility (SSRF) is a third-generation 3.5 GeV synchrotron facility located on the Chinese mainland, operational for user applications since 2009. With the completion of its Phase II project this year, SSRF now supports over 40 experimental stations across various research fields. For the structural biology community, there are three macromolecular crystallography (MX) beamlines (BL02U1, BL17UM and BL10U2) and one endstation at the white X-ray beamline (BL03HB) managed by SSRF to meet the needs of both academic and industrial users seeking to determine macromolecular crystal structures. The MX group at SSRF is dedicated to continuously upgrading these beamlines in terms of technology and scientific capabilities. This paper reports on the current status of all the MX beamlines at SSRF and discusses emerging trends.
19 January 2024 in Journal of Synchrotron Radiation
An integrated computer software system for macromolecular crystallography (MX) data collection at the BL02U1 and BL10U2 beamlines of the Shanghai Synchrotron Radiation Facility is described. The system, Finback, implements a set of features designed for the automated MX beamlines, and is marked with a user-friendly web-based graphical user interface (GUI) for interactive data collection. The Finback client GUI can run on modern browsers and has been developed using several modern web technologies including WebSocket, WebGL, WebWorker and WebAssembly. Finback supports multiple concurrent sessions, so on-site and remote users can access the beamline simultaneously. Finback also cooperates with the deployed experimental data and information management system, the relevant experimental parameters and results are automatically deposited to a database.