TUthe TraumaRegister DGU and the German Pelvic Injury Register of the Deutsche Gesellschaft für Unfallchirurgie
the TraumaRegister DGU and the German Pelvic Injury Register of the Deutsche Gesellschaft für Unfallchirurgie
+4
Introduction: Data on prehospital and trauma-room fluid management of multiple trauma patients with pelvic disruptions are rarely reported. Present trauma algorithms recommend early hemorrhage control and massive fluid resuscitation. By matching the German Pelvic Injury Register (PIR) with the TraumaRegister DGU (TR) for the first time, we attempt to assess the initial fluid management for different Tile/OTA types of pelvic-ring fractures. Special attention was given to the patient's posttraumatic course, particularly intensive care unit (ICU) data and patient outcome. Methods: A specific match code was applied to identify certain patients with pelvic disruptions from both PIR and TR anonymous trauma databases, admitted between 2004 and 2009. From the resulting intersection set, a retrospective analysis was done of prehospital and trauma-room data, length of ICU stay, days of ventilation, incidence of multiple organ dysfunction syndrome (MODS), sepsis, and mortality. Results: In total, 402 patients were identified. Mean ISS was 25.9 points, and the mean of patients with ISS ≥16 was 85.6%. The fracture distribution was as follows: 19.7% type A, 29.4% type B, 36.6% type C, and 14.3% isolated acetabular and/or sacrum fractures. The type B/C, compared with type A fractures, were related to constantly worse vital signs that necessitated a higher volume of fluid and blood administration in the prehospital and/or the trauma-room setting. This group of B/C fractures were also related to a significantly higher presence of concomitant injuries and related to increased ISS. This was related to increased ventilation and ICU stay, increased rate of MODS, sepsis, and increased rate of mortality, at least for the type C fractures. Approximately 80% of the dead had sustained type B/C fractures. Conclusions: The present study confirms the actuality of traditional trauma algorithms with initial massive fluid resuscitation in the recent therapy of multiple trauma patients with pelvic disruptions. Low-volume resuscitation seems not yet to be accepted in practice in managing this special patient entity. Mechanically unstable pelvic-ring fractures type B/C (according to the Tile/OTA classification) form a distinct entity that must be considered notably in future trauma algorithms.
Summary: Reduction of the articular surface in displaced tibial plateau fractures is still challenging and may result in joint incongruence, leading to posttraumatic arthrosis. Conventional techniques use bone tamps and similar instruments, which can increase the surgical trauma due to their size. “Balloon tibioplasty” is a novel minimally invasive technique for the reduction of depressed tibial plateau fractures. We successfully applied an inflatable balloon, commercially available from kyphoplasty, to elevate the depressed articular fragments. This technique allowed for reduction of the depressed tibial plateau fragment without classic fenestration of the tibia, thereby minimizing surgical trauma. Furthermore, under fluoroscopic control, optimal centering of the expanding tibioplasty balloon allows a widespread and continuously increasing reduction force to the fracture area. After fluoroscopy or arthroscopic confirmation of reduction of the articular surface, the cavity resulting from tibioplasty was filled with ceramic bone cement through small incisions and fractures were fixed with a small fragment locking T-plate (3.5 mm). Balloon tibioplasty was applied in 5 patients with displaced tibial plateau fractures (OTA type B2/3). No intra- or postoperative complications were observed. This new technique may be a useful tool to facilitate the reduction of select depressed tibial fractures in the future.