Regular standing interruptions to sedentary work are recommended, but their dosage is understudied. To measure perception variations associated with different sit:stand ratios, 16 people used six ratios (30:0, 27:3, 24:6, 21:9, 18:12 and 15:15) within 30-min cycles in their normal office environment. At start and end of each workday, study participants recorded their perception of 11 factors on a 10-point scale. Musculoskeletal discomfort in 10 body regions was measured before and after exposure to sit-stand ratios. Overall preferred ratios were recorded. Sit:stand ratio affected all perceived factors, with impact varying. Standing at least 6 min improved results most overall; however, individual perceived factors were least impacted by any of 30:0, 27:3, 24:6 or 21:9. Preferred sit:stand ratios were 15:15, 18:12 and 21:9. Typically, least liked ratios involved briefest standing (30:0, 27:3, 24:6) although two participants least liked 15:15. Understanding these variations contributes to appropriate standing dosage recommendations.
The push force and its perception when inserting a flexible hose laterally into a connector were investigated. Effects of hose diameter, glove, target position and obstacle condition were studied. Maximum voluntary insertion forces (MVFs) under similar working conditions were also measured. The larger the diameter, the higher the force required. The peak axial forces for the hoses of 6, 12 and 16 mm in diameter were on average respectively 94, 122 and 184 N, representing 45%, 61% and 93% of MVF. Glove condition, target position and obstacle did not significantly affect the axial insertion force and moment, but they did affect effort perception. Lower effort was perceived with gloves and high and near position. High intra- and inter-individual variability in insertion force for a given hose may suggest that feedback of successful insertion was insufficient. The recognition of a successful insertion must be ensured to avoid unnecessary extra force exertion. Practitioner summary: The effects of glove, hose diameter, target location and obstacle on push force and its perception were studied when inserting a flexible hose. Solutions for improving the recognition of a successful insertion and the hose/connector system design must be found to reduce force exertion to safe levels.
31 July 2015 in Computer Methods in Biomechanics and Biomedical Engineering
Two styles of sit–stand workstations were tested in an emergency (911) call center to quantify postural stress and perception variations. The usual manually adjusted electrically controlled sit–stand workstation was compared with a programmable workstation that automatically changed between seated and standing heights, made forward–backward adjustments, and rotated around the user regularly during a 20-minute cycle. Over 2 working days, neck and seated trunk postures improved with the programmable workstation. Manually controlled sit–stand workstations were not adjusted with the regularity recommended to minimize musculoskeletal discomfort. While seven perceptual measures did not significantly vary between workstations, two others worsened with the programmable workstation: general discomfort and back pain. Participant comments suggested opportunities for design refinements. User training was not included here but would normally further improve results. The programmable workstation improved posture over the manually adjusted workstation, although design refinements and user training in office ergonomics are recommended to maximize benefits. TECHNICAL ABSTRACT Background: Call center workers have high musculoskeletal discomfort, and emergency (911) center workers are among the most affected. Despite many centers including manually controlled sit–stand workstations that facilitate postural changes, these are not typically adjusted with the regularity recommended to minimize musculoskeletal discomfort. Thus, underuse or improper use may be barriers to preventing musculoskeletal disorders and discomfort. Purpose: This study investigates posture and perception of physical factors when using a powered dual-surface manually adjustable workstation and a powered programmable adjustable workstation. Methods: Twelve 911 call-center operators participated. For each workstation, postures were recorded using video cameras over a working day. Nine perception factors were captured at the end of each day using a visual analog scale. Results: Programmable workstation use resulted in significantly lower incidence of at-risk postures in the neck and back and more frequent standing. Perception did not vary significantly between workstations except for an increase in back pain and general discomfort with the programmable workstation. Conclusions: This limited sample exposure to a programmable moving workstation concept should be pursued, though with refinements in larger populations to improve musculoskeletal health of workers in high-stress sedentary environments and should be combined with training. Current observations may be applied to improve programmable workstation aspects that are contributing to perceived discomforts.
4 March 2024 in Proceedings of the Canadian Engineering Education Association (CEEA)
Human Factors or Ergonomics, (HFE) focuses on understanding interactions among humans and other elements of a system, to optimize human well-being and overall system performance. HFE is essential to ensuring engineers are prepared to meet ethical obligations for health, safety, welfare, environment protection, and cultural and societal sensitivity. Two studies measured exposure of graduates of accredited engineering programs to HFE content. Firstly, 37 engineering professors world-wide with knowledge of HFE teachings in their programs responded to a questionnaire. Most perceived HFE exposure as insufficient. Secondly, we searched for HFE keywords within required and technical elective course descriptions of 20 Canadian universities’ engineering programs. HFE keywords were absent from required courses for 68% of programs, and from elective course for 66% of programs; the highest required content was 7.5% of a program. We conclude that HFE is currently under-represented in engineering education to meet required professional obligations of engineers in Canada.