Olga Reitblat

Dr. Olga Reitblat

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
OROlga Reitblat
Olga Reitblat
ALAdi Levy
Adi Levy
GKGuy Kleinmann
Guy Kleinmann
AAAdi Abulafia
Adi Abulafia
EAEhud I. Assia
Ehud I. Assia
To compare the accuracy of different methods that consider posterior corneal curvature in toric intraocular lens (IOL) calculations. Ein-Tal Eye Center, Tel-Aviv, Israel. Retrospective comparative case series. Consecutive cases of toric IOL implantation and preoperative measurements by optical biometry with optical low-coherence reflectometry (OLCR) (Lenstar LS 900) and a Scheimpflug camera (Pentacam) were retrospectively reviewed. Five methods of toric IOL calculation were compared as follows: (1) anterior corneal astigmatism using OLCR, (2) application of the Baylor nomogram, (3) posterior tomography combined with anterior corneal measurements using vector summation, (4) the Scheimpflug camera's true net power, and (5) total corneal refractive power. Toric IOL astigmatic power and axis, aiming for the lowest residual astigmatism, were selected according to these methods. Simulated residual refraction was calculated for each method based on manifest refraction and measured IOL alignment more than 3 weeks after surgery. The study included 115 eyes of 92 patients. The median simulated residual astigmatism was lower when based on vector summation of anterior and posterior astigmatisms than with calculations based on anterior corneal measurements only, application of the Baylor nomogram, true net power, and total corneal refractive power readings (0.49 diopters [D] versus 0.70 D, 0.60 D, 0.64 D, and 0.76 D, respectively) (P < .001). Residual astigmatism after toric IOL implantation can be reduced by appropriate consideration of the posterior corneal astigmatism. Using methods that take into account the effect of the posterior cornea in toric IOL calculations is suggested. Drs. Assia and Kleinmann are consultants to Hanita Lenses, Israel. Dr. Abulafia received a speaker's fee from Haag-Streit AG. No other author has a financial or proprietary interest in any material or method mentioned.

14 January 2015 in Clinical & Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
OROlga Reitblat
Olga Reitblat
EAEhud I Assia
Ehud I Assia
GKGuy Kleinmann
Guy Kleinmann
ALAdi Levy
Adi Levy
GBGraham D Barrett
Graham D Barrett
AAAdi Abulafia
Adi Abulafia

1 September 2017 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
OROlga Reitblat
Olga Reitblat
ALAdi Levy
Adi Levy
GKGuy Kleinmann
Guy Kleinmann
TLTsahi T. Lerman
Tsahi T. Lerman
EAEhud I. Assia
Ehud I. Assia
To compare the accuracy of intraocular lens power prediction for eyes with average keratometry (K) readings greater than 46.00 diopters (D) and lower than 42.00 D. Ein-Tal Eye Center, Tel-Aviv, Israel. Retrospective case series. Eyes having cataract extraction surgery with steep and flat preoperative corneal curvatures determined with the Lenstar-LS900 device were enrolled. Refractive prediction errors for the Barrett Universal II, Haigis, Hill-RBF, Hoffer-Q, Holladay 1, Holladay 2, Olsen, and SRK/T formulas were compared. Optimized K values for the SRK/T formula were back-calculated for each group. Validation was performed using an additional dataset. The study comprised 171 eyes (79, K reading >46.00 D; 92, K reading <42.00 D). For K readings greater than 46.00 D, myopic errors were noted using the SRK/T and Hill-RBF formulas and hyperopic errors using the Olsen C-constant and Haigis (-0.31 D, -0.17 D, 0.18 D, and 0.17 D, respectively). The percentage of eyes with an absolute error within ±0.50 D from target refraction ranged from 60.8% (SRK/T) to 83.0% (Hill-RBF). For K readings lower than 42.00 D, myopic errors were seen using the Haigis, Hill-RBF, Hoffer-Q, and Olsen-C formulas (-0.31 D, -0.14 D, -0.22 D, and -0.17 D, respectively) and a hyperopic error using the SRK/T formula (0.16 D). The refractive prediction within ±0.50 D ranged between 75.0% (Haigis) and 96.7% (Barrett Universal II). Power calculation for eyes with flat corneas and steep corneas requires the use of specific formulas for accurate postoperative results. An adjustment method of the SRK/T formula is proposed.

12 March 2018 in Eye
Verified
Journal Article
Closed access
PDF file
OROlga Reitblat
Olga Reitblat
ALAdi Levy
Adi Levy
GKGuy Kleinmann
Guy Kleinmann
EAEhud I. Assia
Ehud I. Assia

1 December 2020 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
OROlga Reitblat
Olga Reitblat
ALAdi Levy
Adi Levy
EBElinor Megiddo Barnir
Elinor Megiddo Barnir
EAEhud I. Assia
Ehud I. Assia
GKGuy Kleinmann
Guy Kleinmann
PURPOSE: To evaluate different calculation approaches for toric intraocular lens (IOL) calculation in cases with high posterior corneal astigmatism (PCA). METHODS: Consecutive patients who underwent cataract extraction with implantation of toric IOLs by a single surgeon were reviewed. Eyes with measured PCA of 0.80 diopters (D) or greater were included. Errors in the predicted postoperative refractive astigmatism were calculated for the Abulafia-Koch formula, vector summation of anterior keratometry with posterior tomography, and the Barrett toric calculator using predicted and measured PCA. RESULTS: One hundred seventy-three consecutive cases of toric IOL implantation were reviewed. Seventeen eyes (10%) had PCA of 0.80 D or greater and were investigated. The mean absolute error was the lowest with Barrett's measured PCA (0.55 ± 0.38) followed by Barrett's predicted PCA mean absolute error (0.65 ± 0.31), vector summation (0.69 ± 0.33), and the Abulafia-Koch formula (0.80 ± 0.36). The rate of eyes with prediction errors within 0.25 D or less was the highest for Barrett's measured PCA (29.4%) followed by Barrett's predicted PCA (5.9%) and no eyes for the Abulafia-Koch formula and vector summation. The mean centroid prediction errors were lowest for Barrett's measured PCA and Barrett's predicted PCA (0.14 ± 0.66 @70, 0.14 ± 0.73 @179, respectively), followed by vector summation (0.35 ± 0.70 @5), and the Abulafia-Koch formula (0.39 ± 0.80 @179). CONCLUSIONS: The results suggest that in cases of high PCA, the Barrett toric calculator using direct measurements of PCA may have a potential advantage over predicted PCA in toric IOL calculations and vector summation of the anterior and posterior corneal astigmatism. [ J Refract Surg . 2020;36(12):820–825.]

1 July 2023 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
OROlga Reitblat
Olga Reitblat
MBMegiddo Barnir
Megiddo Barnir
AQAyat Qassoom
Ayat Qassoom
ALAdi Mha Levy
Adi Mha Levy
EAEhud I. Assia
Ehud I. Assia
GKGuy Kleinmann
Guy Kleinmann
Purpose: To compare the accuracy of the Barrett toric calculator with measured and predicted posterior corneal astigmatism (MPCA and PPCA, respectively), the Abulafia-Koch (AK) formula, and the toric Kane formula. Setting: Ein-Tal Eye Center, Tel-Aviv, Israel. Design: Retrospective cohort. Methods: Consecutive cases of patients who underwent uneventful cataract extraction surgery with implantation of a toric intraocular lens between March 2015 and July 2019 were retrospectively reviewed. 1 eligible eye from each patient was included. The predicted postoperative refractive astigmatism was calculated using each method and compared with the postoperative refractive astigmatism to give the prediction error. Results: 80 eyes of 80 patients were included in this study. The mean centroid and the mean and median absolute prediction errors using Kane (0.25 diopters [D] ± 0.54 @ 6 degrees, 0.50 D ± 0.31 and 0.45 D, respectively) were significantly different compared with MPCA (0.12 D ± 0.52 @ 16 degrees, P < .001, .44 D ± 0.28 and 0.36 D, P = .027, respectively), PPCA (0.09 D ± 0.49 @ 12 degrees, P < .001, .41 D ± 0.27 and 0.35 D, P < .001, respectively), and AK (0.11 D ± 0.49 @ 11 degrees, P < .001, .42 D ± 0.27 and 0.35 D, P = .004, respectively). No significant differences were found between the calculators in the predictability rates within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D. Conclusions: The measured posterior corneal curvature in the Barrett calculator yielded comparable outcomes to its prediction by the Barrett and AK formulas. The Kane calculator showed a slight against-the-rule prediction error compared with the other methods, resulting in a small higher median absolute error with marginal clinical importance.