Jules Winokur

Dr. Jules Winokur

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
CZCharles Zhang
Charles Zhang
CPCharles Palka
Charles Palka
DZDaniel Zhu
Daniel Zhu
DLDaniel Alexander Lai
Daniel Alexander Lai
JWJules Winokur
Jules Winokur
ARAndrew L. Reynolds
Andrew L. Reynolds
Background: The purpose of the study is to compare the visual outcomes and complications of sutured scleral fixation (SSF), a traditional and conservative surgical approach, and the newer and faster Yamane technique for secondary intraocular lens placement. Methods: A literature search was performed on PubMed, Embase, and Scopus on studies published between 1 July 2017 to 29 September 2023. Outcomes analyzed included the final best corrected visual acuity (BCVA) between 3 and 12 months to assess the effectiveness of the procedure, post-operative month (POM) 1 BCVA to assess the speed of visual recovery, endothelial cell count (ECC), absolute refractive error, surgical duration, and complication rates. Additional subgroup analyses were performed based on surgeon experience with the technique. Single-surgeon studies had an average of 26 procedures performed, whereas multiple-surgeon studies averaged only 9 procedures performed; these were then used to delineate surgeon experience. A sample-size weighted mean difference (MD) meta-analysis was performed across all variables using RevMan 5.4.1; p < 0.05 was considered statistically significant. Results: Thirteen studies with 737 eyes were included: 406 eyes were included in the SSF group, and 331 eyes were included in the Yamane group. There was no significant difference in the final BCVA between groups in both the single-surgeon versus multiple-surgeon studies (MD = −0.01, 95% CI: [−0.06, 0.04], p = 0.73). In the single-surgeon studies, the BCVA at POM1 was significantly improved in the Yamane group compared to SSF (MD = −0.10, 95% CI: [−0.16, −0.04], p = 0.002). In the multiple-surgeon studies, there was no significant difference in BCVA at POM1 (MD = −0.06, 95% CI: [−0.16, 0.04], p = 0.23). The Yamane group had a shorter surgical duration than SSF in both single-surgeon and multiple-surgeon studies (MD = −24.68, 95% CI: [−35.90, −13.46], p < 0.0001). The ECC, refractive error, and complication rates did not significantly differ amongst all groups. Conclusions: The Yamane technique demonstrated similar long-term visual outcomes and complication rates to the traditional SSF. Visual recovery was significantly faster in the Yamane group in the single-surgeon studies. The operative times were shorter across all Yamane groups. Based on these findings, it is advisable to consider the Yamane technique as a viable, and perhaps preferable, option for patients requiring secondary IOL placement, alongside traditional SSF methods.

1 August 2020 in Ophthalmology
Verified
Journal Article
Closed access
RCRoyce W. S. Chen
Royce W. S. Chen
AAAzin Abazari
Azin Abazari
SDSonya Dhar
Sonya Dhar
DFDouglas R. Fredrick
Douglas R. Fredrick
IFIlana B. Friedman
Ilana B. Friedman
JWJules Winokur
Jules Winokur

7 November 2022 in Ocular Immunology and Inflammation
Verified
Journal Article
Closed access
PSParas Shah
Paras Shah
YGYoav Glidai
Yoav Glidai
RBRichard Braunstein
Richard Braunstein
MGMatthew Gorski
Matthew Gorski
JLJung Lee
Jung Lee
ASAnne S. Steiner
Anne S. Steiner
As ophthalmic side effects of messenger RNA (mRNA)-based COVID-19 vaccination are not well understood, it is crucial to document and report such instances should they occur.In this observational ca...

17 September 2025 in Journal of Surgical Education
Verified
Journal Article
Closed access
MKMuhammad Jehanzeb Khan
Muhammad Jehanzeb Khan
MAMuhammad Ali
Muhammad Ali
SASabit Ahmed
Sabit Ahmed
MKMalik Muhammad Hamza Khan
Malik Muhammad Hamza Khan
LGLaura K. Green
Laura K. Green
FWFasika Woreta
Fasika Woreta

24 January 2026 in Journal of Surgical Education
Verified
Journal Article
Closed access
RIRahel M. Imru
Rahel M. Imru
MAMuhammad Ali
Muhammad Ali
ASAhmed Sabit
Ahmed Sabit
LGLaura K. Green
Laura K. Green
JWJules Winokur
Jules Winokur
FWFasika A. Woreta
Fasika A. Woreta

2 September 2025 in Journal of Ophthalmic and Vision Research
Verified
Journal Article
Open access
PDF file
RSRina Su
Rina Su
PSParas Shah
Paras Shah
EBElmira Baghdasaryan
Elmira Baghdasaryan
DZDaniel Zhu
Daniel Zhu
TKTalia Kaden
Talia Kaden
ICIsha Cheela
Isha Cheela
Purpose: To report five cases of structural weakness at the haptic-optic junction of the CT Lucia 602 intraocular lens (IOL) (Carl Zeiss Meditec Inc., Dublin, CA), including two optic breakages and three optic microfractures, while using the Yamane flanged intrascleral haptic fixation surgery (FIHFS). Methods: A retrospective chart review of five cases that underwent Yamane FIHFS by the same surgeon between 2020 and 2022 was performed. Patients’ demographics, operative technique, postoperative outcomes, and adverse events were recorded over a 12-month followup period. Results: One case of optic breakage, noted on postoperative week 1 (POW1), had the optic with the trailing haptic suspended in the vitreous while both haptic flanges remained secured to the sclera, requiring IOL exchange. The second case of optic breakage was noted intraoperatively and required explantation of the IOL with subsequent placement of an iris-fixated IOL. Three cases of optic microfractures were observed with no long-term complications. All five fractures occurred at the junction of the leading haptic. Conclusion: Optic breakage and microfractures at the haptic-optic junction are unusual complications of intrascleral fixated IOL using the Yamane technique. To the best of our knowledge, this has not been previously reported with the CT Lucia 602 IOL. The authors recommend careful selection of the IOL material for this technique to prevent possible complications.