Xi Liu

Mrs. Xi Liu

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
YHYashuo He
Yashuo He
XLXi Liu
Xi Liu
JZJiayi Zhang
Jiayi Zhang
Chang PengChang Peng
Chang Peng
Intravascular ultrasound (IVUS) imaging has been extensively utilized to visualize atherosclerotic coronary artery diseases and to guide coronary interventions. To receive ultrasound signals within the vessel wall safely and effectively, miniaturized ultrasound transducers that meet the strict size constraints and have a simple manufacturing procedure are highly demanded. In this work, the first known IVUS probe that employs a backing-layer-shared dual-frequency structure and a single coaxial cable is introduced, featuring a small thickness and easy interconnection procedure. The dual-frequency transducer is designed to have center frequencies of 30 MHz and 80 MHz, and both have an aperture size of 0.5 mm × 0.5 mm. The total thickness of the dual-frequency transducer is less than 700 µm. In vitro phantom imaging and ex vivo porcine coronary artery imaging experiments are conducted. The low-frequency transducer achieves spatial resolutions of 40 µm axially and 321 µm laterally, while the high-frequency transducer exhibits axial and lateral resolutions of 17 µm and 247 µm, respectively. A bandpass filter is utilized to separate the ultrasound images. Combining in vitro phantom imaging analysis with ex vivo imaging validation, a comprehensive demonstration of the promising application of the proposed miniature ultrasound probe is established.

5 March 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
XLXi Liu
Xi Liu
LYLi Yuanlong
Li Yuanlong
HQHaiguo Qin
Haiguo Qin
Chang PengChang Peng
Chang Peng
Intravascular ultrasound (IVUS) imaging has become an essential method for diagnosing coronary artery disease. However, traditional mechanically rotational IVUS catheters encounter issues such as mechanical wear and imaging distortions in curved vessels. The ring-annular IVUS array has gained attention because it offers superior imaging performance without the need for mechanical rotational parts, thereby avoiding rotational imaging distortion. An optimized mechanical micromachining process employing precision dicing technology is proposed in this study, with the objective of achieving higher operating frequencies and minimized outer diameters for a 64-element ring-annular array. This method broadens the range of fabrication options and improves the imaging sensitivity of ring-annular IVUS arrays, as well as eliminating imaging distortion in rotational IVUS catheters, particularly in curved vessels. The probe has a 7.5 Fr (2.5 mm) outer diameter, with key fabrication steps including precision dicing, flexible circuit integration, and Parylene C encapsulation. The ring-annular array has a center frequency of 21.51 MHz with 67.87% bandwidth, with a 56 µm axial resolution and a 276 µm lateral resolution. The imaging performance is further validated by in vitro phantom imaging and ex vivo imaging.