Kazunori Uemura Kazunori Uemura

Dr. Kazunori Uemura Kazunori Uemura


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2017 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
KUKazunori Uemura Kazunori Uemura
Kazunori Uemura Kazunori Uemura
TKToru Kawada
Toru Kawada
CZCan Zheng
Can Zheng
MLMeihua Li
Meihua Li
MSMasaru Sugimachi
Masaru Sugimachi
Hemodynamic resuscitation in septic shock requires aggressive fluid replacement and appropriate use of vasopressors to optimize arterial pressure (AP) and cardiac output (CO). Because responses to these drugs vary between patients and within patient over time, strict monitoring of patient condition and repetitive adjustment of drug dose are required. This task is time and labor consuming, and is associated with poor adherence to resuscitation guidelines. To overcome this issue, we developed a computer-controlled closed-loop drug infusion system for automated hemodynamic resuscitation in septic shock, and evaluated the performance of the system in a canine model of endotoxin shock. Our system monitors AP, CO and central venous pressure, and computes arterial resistance (R), stressed blood volume (V) and Frank-Starling slope of left ventricle (S). The system controls R with noradrenaline (NA), and V with Ringer’s acetate solution (RiA), thereby controlling AP and CO. In 4 dogs, AP and CO were measured invasively. In another 4 dogs, AP and CO were measured less invasively using clinically acceptable modalities, aiming to make the system clinically feasible. In all 8 dogs, endotoxin shock was induced by injecting Escherichia coli lipopolysaccharide, which significantly decreased AP from 95 (91–108) to 43 (39–45) mmHg, and CO from 112 (104–142) to 62 (51–73) ml·min−1·kg−1. The system was then connected to the dogs, and activated. System performance was observed over a period of 4 h. Our system immediately started infusions of NA and RiA. Within 40 min, RiA increased V to target level, and NA maintained R at target level, while S was concomitantly increased. These resulted in restoration of AP to 70 (69–71) mmHg and CO to 130 (125–138) ml·min−1·kg−1. Median of absolute performance error, an index of precision of control, was small in AP [2.5 (2.1–4.5) %] and CO [2.4 (1.4–5.5) %], which were not increased even when the variables were measured less invasively. In a canine model of endotoxin shock, our system automatically improved and maintained AP and CO at their target values with small performance error. Our system is potentially an attractive clinical tool for rescuing patients with septic shock.

1 February 2007 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
TKToru Kawada
Toru Kawada
HKHirotoshi Kitagawa
Hirotoshi Kitagawa
TYToji Yamazaki
Toji Yamazaki
TATsuyoshi Akiyama
Tsuyoshi Akiyama
AKAtsunori Kamiya
Atsunori Kamiya
MSMasaru Sugimachi
Masaru Sugimachi
Although hypothermia is one of the most powerful modulators that can reduce ischemic injury, the effects of hypothermia on the function of the cardiac autonomic nerves in vivo are not well understood. We examined the effects of hypothermia on the myocardial interstitial norepinephrine (NE) and ACh releases in response to acute myocardial ischemia and to efferent sympathetic or vagal nerve stimulation in anesthetized cats. We induced acute myocardial ischemia by coronary artery occlusion. Compared with normothermia (n = 8), hypothermia at 33°C (n = 6) suppressed the ischemia-induced NE release [63 nM (SD 39) vs. 18 nM (SD 25), P < 0.01] and ACh release [11.6 nM (SD 7.6) vs. 2.4 nM (SD 1.3), P < 0.01] in the ischemic region. Under hypothermia, the coronary occlusion increased the ACh level from 0.67 nM (SD 0.44) to 6.0 nM (SD 6.0) (P < 0.05) and decreased the NE level from 0.63 nM (SD 0.19) to 0.40 nM (SD 0.25) (P < 0.05) in the nonischemic region. Hypothermia attenuated the nerve stimulation-induced NE release from 1.05 nM (SD 0.85) to 0.73 nM (SD 0.73) (P < 0.05, n = 6) and ACh release from 10.2 nM (SD 5.1) to 7.1 nM (SD 3.4) (P < 0.05, n = 5). In conclusion, hypothermia attenuated the ischemia-induced NE and ACh releases in the ischemic region. Moreover, hypothermia also attenuated the nerve stimulation-induced NE and ACh releases. The Bezold-Jarisch reflex evoked by the left anterior descending coronary artery occlusion, however, did not appear to be affected under hypothermia.

31 May 2014 in Heart and Vessels
Verified
Journal Article
Closed access
PDF file
KUKazunori Uemura Kazunori Uemura
Kazunori Uemura Kazunori Uemura
MIMasashi Inagaki
Masashi Inagaki
CZCan Zheng
Can Zheng
MLMeihua Li
Meihua Li
TKToru Kawada
Toru Kawada
MSMasaru Sugimachi
Masaru Sugimachi

1 July 2019 in Shock
Verified
Journal Article
Closed access
KUKazunori Uemura Kazunori Uemura
Kazunori Uemura Kazunori Uemura
TKToru Kawada
Toru Kawada
CZCan Zheng
Can Zheng
MLMeihua Li
Meihua Li
MSMasaru Sugimachi
Masaru Sugimachi
In septic shock, it is not known whether β-blocker can be used to reduce heart rate (HR) safely during the initial phase of hemodynamic resuscitation. The purpose of this study was to experimentally investigate the effects of low-dose landiolol, a β-blocker, on initial hemodynamic resuscitation in dogs with endotoxin shock. In 13 anesthetized dogs [n = 7 in control (CT) group, n = 6 in β-blockade (BB) group], after endotoxin shock was induced by intravenous infusion of lipopolysaccharide (4 mg kg−1), we started hemodynamic resuscitation to restore mean arterial pressure (AP) and cardiac output (CO) by infusing noradrenaline (NA) and Ringer acetate solution (RiA). During 4 h of hemodynamic resuscitation, dose of NA and RiA were automatically titrated with use of a computer-controlled drug infusion system that we developed previously. In BB group, landiolol was administered at a low-dose range (1–10 μg kg−1 min−1) to lower HR to lower than 140 bpm. Hemodynamic resuscitation using the system restored AP to 70 mmHg and CO to greater than 90% of baseline level similarly in both groups. Throughout resuscitation, HR and indices of cardiac contractility were significantly lower in BB group than in CT group. However, there were no significant intergroup differences in the dose of NA and RiA. During First 2 h of resuscitation, cardiac oxygen consumption was significantly lower in BB group than in CT group. In conclusion, low-dose landiolol may reduce HR without compromising initial hemodynamic resuscitation in septic shock. To clearly establish this, large-size randomized study using animal models more relevant to septic shock is needed.

10 May 2021 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
TNTakuya Nishikawa
Takuya Nishikawa
KUKazunori Uemura Kazunori Uemura
Kazunori Uemura Kazunori Uemura
YHYohsuke Hayama
Yohsuke Hayama
TKToru Kawada
Toru Kawada
KSKeita Saku
Keita Saku
MSMasaru Sugimachi
Masaru Sugimachi
Beta-blockers are well known to reduce myocardial oxygen consumption (MVO2) and improve the prognosis of heart failure (HF) patients. However, its negative chronotropic and inotropic effects limit their use in the acute phase of HF due to the risk of circulatory collapse. In this study, as a first step for a safe β-blocker administration strategy, we aimed to develop and evaluate the feasibility of an automated β-blocker administration system. We developed a system to monitor arterial pressure (AP), left atrial pressure (PLA), right atrial pressure, and cardiac output. Using negative feedback of hemodynamics, the system controls AP and PLA by administering landiolol (an ultra-short-acting β-blocker), dextran, and furosemide. We applied the system for 60 min to 6 mongrel dogs with rapid pacing-induced HF. In all dogs, the system automatically adjusted the doses of the drugs. Mean AP and mean PLA were controlled within the acceptable ranges (AP within 5 mmHg below target; PLA within 2 mmHg above target) more than 95% of the time. Median absolute performance error was small for AP [median (interquartile range), 3.1% (2.2–3.8)] and PLA [3.6% (2.2–5.7)]. The system decreased MVO2 and PLA significantly. We demonstrated the feasibility of an automated β-blocker administration system in a canine model of acute HF. The system controlled AP and PLA to avoid circulatory collapse, and reduced MVO2 significantly. As the system can help the management of patients with HF, further validations in larger samples and development for clinical applications are warranted.

17 December 2024 in ASAIO Journal
Verified
Journal Article
Closed access
TUTakashi Unoki
Takashi Unoki
KUKazunori Uemura Kazunori Uemura
Kazunori Uemura Kazunori Uemura
SYShohei Yokota
Shohei Yokota
HMHiroki Matsushita
Hiroki Matsushita
MKMidori Kakuuchi
Midori Kakuuchi
KSKeita Saku
Keita Saku
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) benefits patients with cardiogenic shock (CS) but can increase left ventricular afterload and exacerbate pulmonary edema. Adding a percutaneous left ventricular assist device (LVAD) to VA-ECMO can optimize the hemodynamics. Because managing VA-ECMO and LVAD simultaneously is complex and labor-intensive, we developed a closed-loop automated control system for VA-ECMO and LVAD. Based on the circulatory equilibrium framework, this system automatically adjusts VA-ECMO and LVAD flows and cardiovascular drug and fluid dosages to achieve target arterial pressure (AP, 70 mm Hg), left atrial pressure (P LA, 14 mm Hg), and total systemic flow (F total, 120–140 ml/min/kg). In seven anesthetized dogs with CS, VA-ECMO significantly increased AP and P LA from 24 (23–27) to 71 (63–77) mm Hg and 20.1 (16.3–22.1) to 43.0 (25.7–51.4) mm Hg, respectively. Upon system activation, P LA was promptly reduced. At 60 min postactivation, the system-controlled AP to 69 (65–74) mm Hg, P LA to 12.5 (12.0–13.4) mm Hg, and F total to 117 (114–132) ml/min/kg while adjusting VA-ECMO flow to 59 (12–60) ml/min/kg, LVAD flow to 68 (54–78) ml/min/kg, and cardiovascular drug and fluid dosages. This system automatically optimizes VA-ECMO and LVAD hemodynamics, making it an attractive tool for rescuing patients with CS.