Background: Coronary and carotid artery diseases are manifestations of a systemic atherosclerotic process, often coexisting in patients affected by both conditions. This association emphasizes the importance of evaluating both coronary and carotid atherosclerosis in high-risk individuals. Ultrasound 2D shear-wave elastography (2D-SWE) has shown promise as a noninvasive technique for assessing carotid plaque stiffness. This prospective pilot study aimed to assess carotid plaque stiffness in patients undergoing coronary artery bypass grafting (CABG) and those not scheduled for the procedure as a control group. Methods: 32 patients (17 CABG and 15 controls) were recruited, collectively presenting 43 carotid plaques. Bilateral carotid ultrasound was performed using a high-resolution linear transducer. Plaque stiffness was quantified via 2D-SWE, expressed in shear-wave velocity (SWV, m/s) and Young’s modulus (YM, kPa). Plaque characteristics, including GSM, were quantified. Intra-observer reproducibility was evaluated with intraclass correlation coefficients (ICCs) and Bland–Altman plots. Statistical differences and correlations were assessed using Mann–Whitney U and Spearman’s correlation tests. Results: Carotid plaques in the CABG group exhibited significantly lower stiffness compared to controls (median stiffness SWV: 3.64 m/s vs. 4.91 m/s, p < 0.0001; YM: 20.96 kPa vs. 72.54 kPa, p < 0.0001). ICCs demonstrated excellent reproducibility for stiffness measurements (SWV: ICC = 0.992; YM: ICC = 0.992), with minimal bias in measurements. A positive correlation was observed between 2D-SWE and GSM values (SWV: r = 0.343, p = 0.024; YM: r = 0.340, p = 0.026). Conclusions: Ultrasound 2D-SWE has shown promise as a reliable tool for quantifying carotid plaque stiffness, demonstrating high reproducibility and a significant correlation with GSM. The observed reduction in plaque stiffness among CABG patients highlights its potential as a valuable parameter for identifying high-risk plaques and assessing cerebrovascular risk in patients undergoing CABG.
Introduction: Treatment decision of lower extremity peripheral arterial disease (PAD) is governed by the severity of stenosis. Tomographic 3D ultrasound (t3DUS) is a reliable imaging technique for measuring vessel stenosis. In this study we attempted to provide a precise measurement of superficial femoral artery (SFA) stenosis using t3DUS in patients with PAD. Methods: t3DUS was used to measure maximum stenosis percentage in SFA from 50 patients with lower extremity PAD. The maximum stenosed segment in SFA was defined using Duplex 2DUS aliasing was noted. The peak systolic velocity (PSV) was measured at the maximum stenotic site and proximal to aliasing for calculating the velocity ratio. The association between blood flow velocity ratio and the degree of stenosis measured using Duplex 2DUS and t3DUS, respectively, was assessed using Spearman rank correlation. Results: There was a strong positive correlation between velocity ratio and degree of stenosis in SFA measured using t3DUS (correlation value (r) = 0.99, p < 0.001). The correlation between Stenosis percentage and velocity ratio in SFA are as followed: <50:80:>5. t3DUS can be used to provide precise measurement of the severity of SFA stenosis in patients with lower extremities arterial disease. The established criteria for grading SFA stenosis in this study can be applied to the current practice alongside Duplex 2DUS as it showed a strong positive correlation with velocity ratio. Further studies investigating the sensitivity and specificity of t3DUS in the assessment of stenosis in lower limbs arteries are required.
Background/Objectives: Ultrasound shear-wave elastography (SWE) enables quantitative assessment of tissue stiffness and may provide a non-invasive biomarker of carotid plaque vulnerability. This study aimed to evaluate the ability of SWE to differentiate symptomatic from asymptomatic carotid plaques and to assess its reproducibility. Methods: A systematic search of PubMed, Web of Science, EMBASE, and the Cochrane Library was conducted in the last ten years until January 2026 for publications evaluating carotid plaques using ultrasound SWE. Inclusion criteria required original publications that used quantitative ultrasound SWE parameters for the evaluation of carotid plaque in symptomatic and asymptomatic patients and/or investigated the reproducibility of SWE parameters for carotid plaques; non-carotid studies, non-original articles, and studies not comparing symptomatic versus asymptomatic plaques or not reporting reproducibility were excluded. Fourteen studies comprising 1781 carotid plaques were included. Quantitative SWE measurements were meta-analyzed using random effects. Differences between symptomatic and asymptomatic plaques were assessed using standardized mean differences (SMDs). The reproducibility of SWE measurements was evaluated using pooled correlation coefficients. Publication bias was evaluated using funnel plots and Egger’s regression test. Results: Ten studies including 1246 plaques compared SWE stiffness between symptomatic (n = 472) and asymptomatic plaques (n = 774). The meta-analysis demonstrated significantly lower stiffness values in symptomatic plaques compared with asymptomatic plaques (SMD −1.10, p < 0.001). Reproducibility analysis of correlation coefficients extracted from seven studies demonstrated excellent agreement for SWE measurements (r = 0.92, n = 602). Heterogeneity was observed across the included studies. No statistically significant evidence of publication bias was detected. Conclusions: Ultrasound SWE is a promising approach for assessing carotid plaque vulnerability, with lower SWE stiffness observed in symptomatic plaques compared to asymptomatic plaques. This finding should be interpreted with consideration of methodological heterogeneity and the cross-sectional nature of the available assessed evidence. Further prospective studies with standardized imaging protocols and longitudinal follow-up are needed to determine clinically applicable stiffness thresholds and evaluate the prognostic value of ultrasound SWE in cerebrovascular risk stratification.
Background: Tomographic 3D ultrasound (t3DUS) is a promise imaging technique for quantifying carotid plaque through measuring the degree of stenosis and plaque volume. Carotid plaque volume (CPV) could add benefit in predicting the potential risk of stroke. Purpose: To assess the reproducibility and accuracy of t3DUS for measuring CPV within the internal carotid artery in patients undergoing carotid endarterectomy. Material and Methods: t3DUS was used to obtain CPV in vivo from 25 symptomatic patients prior to surgery. Ex vivo CPV from the carotid endarterectomy specimen was then measured using a validated saline displacement method as a reference standard. CPV for each patient was measured twice using both methods (total n = 50 per technique). Intraclass correlation coefficient (ICC) and Bland–Altman plot were used to establish bias and limit of agreement between CPV measurements. Results: There was an excellent agreement between t3DUS and reference test with respect to measuring CPV with an ICC value of 0.98 (95% confidence interval = 0.97–0.99, P < 0.001). Bias in measurements was 0.02 ± 0.11 cm3 (95% limit of agreement = −0.19 to 0.25). Intra-observer agreement of t3DUS CPV measurements was excellent with an ICC value of 0.95 (95% confidence interval = 0.92–0.97, P < 0.001). Bias in measurements was 0.004 ± 0.07 cm3 (95% limit of agreement = −0.14 to 0.15). Conclusion: t3DUS is a reproducible imaging method and showed excellent agreement with the reference standard with respect to measuring CPV. These findings suggest that t3DUS has the potential to be a valuable non-invasive tool for assessing carotid plaque burden and predicting the risk of stroke.
5 December 2025 in International Journal of Biomedicine