Valentyn Lysko

Dr. Valentyn Lysko

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2012 in Journal of Electronic Materials
Verified
Journal Article
Closed access
PDF file
LAL. I. Anatychuk
L. I. Anatychuk
NHN. V. Havrylyuk
N. V. Havrylyuk
VLValentyn Lysko
Valentyn Lysko

25 July 2014 in Journal of Electronic Materials
Verified
Journal Article
Closed access
PDF file
LAL.I. Anatychuk
L.I. Anatychuk
VLValentyn Lysko
Valentyn Lysko

11 June 2015 in Materials Today: Proceedings
Verified
Journal Article
Closed access
LAL.I. Anatychuk
L.I. Anatychuk
MHM.V. Havryliuk
M.V. Havryliuk
VLValentyn Lysko
Valentyn Lysko

1 January 2012 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
LAL. I. Anatychuk
L. I. Anatychuk
VLValentyn Lysko
Valentyn Lysko

7 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
RKRoman Kobylianskyi
Roman Kobylianskyi
Krzysztof PrzystupaKrzysztof Przystupa
Krzysztof Przystupa
VLValentyn Lysko
Valentyn Lysko
JMJacek Majewski
Jacek Majewski
LVLyudmyla Vikhor
Lyudmyla Vikhor
NPNataliya Pasyechnikova
Nataliya Pasyechnikova
Perioperative monitoring of the ocular heat transfer is important for increasing the safety of long-term vitreoretinal surgery. The study is aimed at studying new thermoelectric measuring devices for comprehensive perioperative monitoring of ocular temperature and heat fluxes in vitreoretinal surgery. This pilot, open-label, prospective study included 23 patients (23 eyes) with proliferative diabetic retinopathy (PDR) in both eyes. The thermoelectric devices were developed for measuring intraocular temperature in vitreoretinal surgery and for determining the ocular surface temperature (OST) and heat flux (HF) density. In all cases, OST and HF density of both eyes were recorded (before and after surgery). Intraocular temperature and temperature of the irrigation fluid were measured intraoperatively. No complications associated with the perioperative use of thermoelectric temperature and HF sensors were identified during the study. The successful application of thermoelectric temperature and HF sensors, developed specifically for ophthalmological applications, in comprehensive perioperative monitoring of ocular heat transfer in patients with PDR in vitreoretinal surgery was demonstrated for the first time. Further research is needed to confirm the benefits of perioperative temperature monitoring in vitreoretinal surgery, as well as to develop equipment for active management of temperature in surgical practice.

7 March 2025 in Journal of Applied Physics
Verified
Journal Article
Open access
LVLyudmyla Vikhor
Lyudmyla Vikhor
VLValentyn Lysko
Valentyn Lysko
MKM. Kotsur
M. Kotsur
MHM. Havrylyuk
M. Havrylyuk
The research is aimed at approaches to increasing the efficiency of thermoelectric coolers (TECs) for IR detectors and the development of experimental methods and tools for their implementation. One way is to optimize Bi2Te3-based materials by using inhomogeneous materials. Another way is to optimize the module design taking into account the electrical and thermal resistances of the contacts in the module, which reduce the coefficient of performance (COP). A new numerical method based on the optimal control theory is proposed for designing modules in the maximum COP mode. The results of the COP calculation prove that reducing the electrical contact resistance is the predominant factor for improving the efficiency of modules for IR detectors. The COP of coolers increases by 1.5–2.5 times compared to commercial modules if the contact resistance is brought closer to the minimum value of 10−7 Ω cm2. The use of inhomogeneous thermoelements and insulating plates made of aluminum nitride instead of alumina ceramics provides an additional increase in COP by 10% and 20%, respectively. To control the contact resistance, an improved probe method of measuring is proposed. Computer simulation is applied to estimate the uncertainty of contact resistance measuring by this method. It is proven that the uncertainty does not exceed 2%.