Fault detection, classification, and precise location identification in power transmission lines are critical issues for energy transmission and power systems. Accurate fault diagnosis is essential for system stability and safety as it enables rapid problem resolution and minimizes interruptions in electrical energy supply. The characteristic parameters of mixed-conductor power transmission lines connected to the grid were calculated using the relevant line data. Based on these parameters, a dataset was created with computer-derived values. This dataset included variations in arc resistance and the short circuit power of the corresponding bus, facilitating the performance testing of various machine learning algorithms. It was observed that the correct determination of the faulty phase was of high importance in the correct determination of the fault position. For this reason, a gradual structure was preferred. It was achieved with a 100 percent success rate in fault detection with the ensemble bagged algorithm. It was obtained with the neural network algorithm with a 99.97 percent success rate in faulty phase detection. The most successful location results were obtained with the interaction linear algorithm with 0.0066 MAE for phase-to-phase faults and the stepwise linear algorithm with 0.0308 MAE for phase ground faults. Using the proposed algorithm, fault locations were identified with a maximum error of 26 m for phase-to-ground faults and 110 m for phase-to-phase faults on a transmission line with a mixed conductor of approximately 178 km. Additionally, we compared the training and testing results of several machine learning algorithms metrics including the accuracy, total error, mean absolute error, root mean square, and root mean square error to provide informed recommendations based on their performance. The findings aim to guide users in selecting the most effective machine learning models for predicting failures in transmission lines.
1 December 2019 in Sakarya University Journal of Science
In this study, a DC-DC buck converter circuit which is used to get direct voltage by decreasing the source voltage is researched. Firstly mathematical model for a DC-DC buck converter circuit is obtained and critical inductance value is calculated to make it work in continuous current mode. Then for controlling a DC-DC buck converter, three different controllers in discrete time (sliding mode control, proportional–integral–derivative controller and linear quadratic regulator) are designed. Finally, the performance of these controllers according to changing in the form of step function for input voltage, reference voltage and load conditions are examined and compared with real time studies. According to obtained results, a DC-DC buck converter circuit controlled by sliding mode controller has shown a better performance compared to the other controllers.
1 January 2026 in IET Generation, Transmission & Distribution
Energy transmission lines are critical for reliable electricity delivery, but faults in these lines can disrupt power systems, leading to instability and outages. Rapid fault detection, accurate classification, and timely isolation are essential to maintain grid resilience. Traditional distance relays are widely used for fault detection. However, due to dynamic variations in system conditions and external disturbances, they face limitations in complex scenarios. This situation highlights the need for more advanced and precise fault detection methods. In this study, parametric analyses were conducted on a 400 kV medium‐length transmission line, and various fault scenarios were created using system characteristic data with various program software to generate a dataset. The performance of deep learning techniques in fault detection was comparatively analysed based on the obtained datasets. Notably, the proposed hybrid deep learning algorithm outperformed other classification algorithms in predicting critical information such as fault type and zone detection. The proposed hybrid framework demonstrates strong predictive performance, ensuring high accuracy in fault type classification, 99.994%, and zone localisation, 99.981%. By systematically integrating conventional protection schemes with advanced computational methodologies, the approach is anticipated to significantly enhance the reliability and operational efficiency of fault management in high‐voltage transmission networks.
Community-based energy sharing requires a local trading mechanism that provides economic incentives for both energy suppliers and consumers. This study proposes OptiPro, a framework for enabling a residential local energy market in which renewable-energy producers and storage owners can sell available electricity at prices above conventional grid-export tariffs, while purchasing households can obtain electricity below external retail rates. Its central contribution is the coordinated operation and evaluation of this mutually beneficial trading arrangement across heterogeneous residential participants. A bi-level optimization model, reformulated using Karush–Kuhn–Tucker conditions and the Big-M method, coordinates photovoltaic and wind generation, individual and shared battery storage, and hydrogen storage as enabling resources for the local market. The framework is evaluated using five representative residential profiles in Çanakkale, Türkiye, under three operating scenarios: grid-dependent operation, renewable integration without coordinated trading, and active OptiPro management. The simulation results demonstrate a fundamental financial transformation driven by intelligent arbitrage and shared resource management. The proposed system converts the microgrid from a daily operational cost of $10.35 in the baseline scenario to a net revenue of $0.63, effectively creating a profit-generating ecosystem where users transition from passive consumers to active prosumers. This paradigm shift corresponds to a projected total annual economic benefit of approximately $4000 for the community. A detailed analysis of individual participant behavior highlights the superior efficiency of hybrid configurations; Home-4 (PV-Wind) achieved the highest economic performance, recording a 181% increase in profit rate with annual earnings of $1414. Simultaneously, the model ensures energy equity; even passive consumers without generation capacity, represented by Home-1, realized a 13.6% reduction in electricity costs solely through community arbitrage. Beyond the economic benefits, the technical performance assessment showed that OptiPro reduced peak grid-purchase power from 5.5 kW in the baseline scenario to 3.8 kW, corresponding to a reduction of approximately 31%, and decreased the standard deviation of hourly grid-exchange power by 38%. The renewable-energy consumption rate increased from approximately 68% under uncoordinated operation to 96% with OptiPro. These results demonstrate improved peak shaving, smoother grid exchanges, and greater local utilization of renewable generation under the evaluated operating conditions. These findings indicate that coordinating hybrid renewable sources with shared storage can improve operational energy management and trading outcomes under the evaluated assumptions. The long-term financial feasibility of the proposed configuration requires further assessment of investment, maintenance, and replacement costs.