Purpose: To assess and compare the diagnostic accuracy of the GenBody COVID-19 Antigen kit (GenBody Inc., Cheonan, South Korea) available in the market with the gold standard reverse transcription-polymerase chain reaction (RT-PCR) assay to detect severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Methods: Nasopharyngeal and oropharyngeal swabs were collected from suspected coronavirus disease 2019 (COVID-19) patients and tested by RT-PCR and GenBody Rapid antigen kit. Performance characteristic of the antigen kit was calculated. Results: We tested nasopharyngeal swabs and oropharyngeal swabs (n=240). Amongst the 102 positive RT-PCR samples, the rapid antigen test detected 36 as positive, showing an overall sensitivity of 35.3%. All the samples detected positive with the antigen rapid test were also detected positive by RT-PCR. Conclusion: The performance of the rapid antigen kit was good with respect to high viral load samples, whereas those with lower levels were missed. Unfortunately, the overall low sensitivity of the antigen kit does not allow using it alone as the frontline testing kit for COVID-19 diagnosis.
Introduction: Hepatitis B is the most prevalent virus that causes severe liver infection worldwide. According to the current guidelines, the HBV viral load and other factors can help in treatment decisions. Therefore, the present study explores the relationship between the HBV viral load and blood-based laboratory parameters. Methods: The HBV viral load was evaluated in blood samples from 159 HBsAg-positive patients (ICT-positive). The viral load was categorized as high (above 200,000 IU/mL), moderate (between 2000 and 200,000 IU/mL), or low (below 2000 IU/mL). The viral load was then compared with laboratory parameters. Results: A significant association was observed between the Hepatitis B viral load and the patient’s age (p < 0.01). The males showed a substantially higher viral load, with 29.2% of the male patients exhibiting elevated levels, compared to 11% of the females. A statistically significant correlation was found between the viral load and liver enzymes, specifically AST (p < 0.005) and ALT (p < 0.04), as well as calcium (p < 0.01). Notably, the elevated ALT and AST levels were more pronounced in the patients with moderate and high viral loads, suggesting a potential link to liver dysfunction. A remarkable insight uncovered in our study revolves around the notable increase in the serum calcium levels (p < 0.01). Conclusions: The AST, ALT, and serum calcium levels were the most altered parameters with high HBV viral load. Though limited reports are available on altered serum calcium levels, they could serve as potential laboratory markers for assessing disease progression in HBV infection. Moreover, focusing on potential therapies to normalize the AST, ALT, and serum calcium levels could offer promising avenues for combating HBV infection.
His initial haemoglobin was 12.2 g/dL and white cell count 23×109/L without eosinophilia. His blood, urine and endotracheal (ET) aspirate cultures were sterile. ET aspirate was sent for acid-fast staining which showed numerous larvae while acid-fast bacilli were not present. Wet mount of tracheal aspirate revealed rhabditiform larvae of Strongyloides stercoralis along with embryonated eggs, wherein many were observed to be in hatching phase (video 1 and figure 1). The findings were further confirmed by iodine mount and Giemsa staining (figure 2). Multiple samples of ET aspirates and gastric aspirate were examined while only one stool sample could be obtained, probably due to intestinal obstruction. Rhabditiform larvae and eggs of S. stercoralis were not found in gastric aspirate as well as in stool sample. Filariform larva wasn’t observed in any of the samples examined. The patient was nebulised with levosalbutamol and ipratropium bromide combination along with budesonide; and was started on ivermectin 200 μg/kg/day via a nasogastric tube which could be given only for 5 days. The patient also received a short course of hydrocortisone therapy (100 mg intravenous stat followed by 50 mg 6 hourly for 3 days). The patient clinically deteriorated and expired.
India had faced three waves throughout the Coronavirus disease 2019 (COVID-19) pandemic, which had already impacted economic lives and affected the healthcare setting and infrastructure. The widespread impacts have inspired researchers to look for clinical indicators of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection prognosis. Cyclic threshold values have been used to correlate the viral load in COVID-19 patients and for viral transmission. In light of this correlation, a retrospective study was conducted to assess the trend of viral load in clinical and demographic profiles across the three waves. Data of a total of 11,125 COVID-19-positive patients were obtained, which had a Ct value of <35. We stratified Ct values as follows: under 25 (high viral load), 25–30 (moderate viral load), and over 30 (low viral load). We found a significantly high proportion of patients with high viral load during the second wave. A significantly high viral load across the symptomatic and vaccinated populations was found in all three waves, whereas a significantly high viral load across age groups was found only in the first wave. With the widespread availability of real-time PCR and the limited use of genomic surveillance, the Ct value and viral load could be a suitable tool for population-level monitoring and forecasting.