Luís Felipe Espindola-Castro

Dr. Luís Felipe Espindola-Castro


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2019 in Operative Dentistry
Verified
Journal Article
Closed access
LELuís Felipe Espindola-Castro
Luís Felipe Espindola-Castro
ARA Rosenblatt
A Rosenblatt
AGA Galembeck
A Galembeck
GMGqm Monteiro
Gqm Monteiro
Clinical Relevance: The new formulations of nano-silver fluoride caused less dentin staining than the already available commercial agents 35% silver fluoride and silver diamine fluoride at 30% and 38%.SUMMARY: The objective of this study was to evaluate the dentin staining potential of nano-silver fluoride (NSF 600 and 1500 ppm) compared with the following commercially available cariostatic agents: Advantage Arrest (Elevate Oral Care, West Palm Beach, FL, USA), Riva Star (SDI, Victoria, Australia), and Cariestop (Biodinâmica, Paraná, Brazil). Seventy-five extracted human molars were sectioned at the cementoenamel junction, and the occlusal enamel was removed for exposure of coronary dentin. The samples were divided among the five agents tested (n=15). The dentin staining (ΔE/ΔL) was analyzed with a digital spectrophotometer (VITA Easyshade, VITA Zahnfabrik, Bad Säckingen, Germany) at three different time points (before application, after two weeks, and after four weeks). Photographic images were also performed. The Kruskal-Wallis and Mann-Whitney tests compared the mean ΔE and ΔL values between groups. The NSF 600 and 1500 ppm resulted in the smallest color change (ΔE=1.02 and 1.53) and dentin staining after four weeks (ΔL=−0.76 and −1.2). The new formulations differed significantly from the commercial cariostatic agents (p<0.001). NSF might be an alternative to silver diamine fluoride since it does not compromise esthetics.

1 January 2020 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
LELuís Felipe Espindola-Castro
Luís Felipe Espindola-Castro
MDMa. Durão
Ma. Durão
TPT. Pereira
T. Pereira
ACAb. Cordeiro
Ab. Cordeiro
GMGm. Monteiro
Gm. Monteiro
Due to the increasing popularity of bulk fill resins, there is a concern that their components can be leached; this is because these are inserted in a single 4-5 mm increment. This in vitro study evaluated the microhardness, sorption, solubility, and color stability of three restorative bulk fill resins, namely: Filtek Bulk Fill (FBF), Tetric N-Ceram Bulk Fill (TNC), and Opus Bulk Fill (OBF). Cylindrical samples were fabricated to be 15 mm in diameter and 1 mm thick (n = 10). For the microhardness test, three random indentations were formulated on the samples using a micro-durometer with a load of 300 gf for 15 s. Sorption and solubility were then evaluated (ISO 4049: 2009). Color stability was analyzed with a digital spectrophotometer three times (initially, after 24 h, and after 7 d) during immersion in coffee and distilled water (control). The Shapiro-Wilk test was applied to analyze normality. The Mann-Whitney and Kruskal-Wallis tests were used to compare the groups and the immersion solution, with a significance level of 5%. There were a significant difference in microhardness (p<0.001), with the FBF group showing a higher value compared to the other groups (56.38). The highest average of sorption scores was observed in the OBF group (16.9 µg / mm3), followed by FBF (16.8 µg / mm3) and TNC (11.3 µg / mm3). Solubility was lowest in the OBF group (-2.83 µg / mm3), with a significant difference (p = 0.031). There was also a significant difference after 24 h in the mean ∆E score of all groups (p<0.005). After one week of immersion, the group that pigmented most was OBF (p = 0.008). The three bulk fill resins had acceptable hardness, sorption, and solubility values. However, all groups showed a high pigmentation rate after 7 d of immersion in coffee. Key words:Bulk fill, color stability, composite resins, microhardness, solubility, sorption.

1 February 2020 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
LELuís Felipe Espindola-Castro
Luís Felipe Espindola-Castro
OBOscar Felipe Fonseca de Brito
Oscar Felipe Fonseca de Brito
LALarissa Gabrielle Assis Araújo
Larissa Gabrielle Assis Araújo
ISIzabella Luiza Aragão Santos
Izabella Luiza Aragão Santos
GMGabriela Queiroz De Melo Monteiro
Gabriela Queiroz De Melo Monteiro
Objective The aim of study was to evaluate in vitro the surface hardness, sorption, solubility, and color stability of three light-cured resin cements, namely RelyX Veneer (RLX), Variolink Veneer (VLK), and All Cem Veneer (ACV). Materials and Methods Cylindrical samples (15 × 1 mm) were made for each group using a metallic mold (n = 10). Vickers microhardness test was performed, and average hardness was calculated from three indentations (300 gf/15s) per sample. The sorption and solubility of the materials were evaluated according to ISO 4049:2009 based on three samples weighing: initial (m 1), after immersion in distilled water for 7 days (m 2), and final (after removal of all moisture [m 3]). The color change was observed using a digital spectrophotometer, at three different time points, baseline, 1 day, and 1 week of immersion in coffee and distilled water (control). Statistical Analysis Shapiro–Wilk test was used to analyze the normality of the data, and groups were compared using Kruskal–Wallis and Mann–Whitney tests. A significance level of 5% was used. Results RLX showed the highest microhardness mean values (36.96 VHN), but higher sorption (23.2 µg/mm3) and solubility (2.40 µg/mm3), with statistically significant differences with the other groups. For color stability, higher ∆E was observed for the samples immersed in coffee (p = 0.009). The VLK resin cement presented statistically significant differences from the other groups, with higher color changes in coffee at 1 day (15.14) and after 1 week (23.65). Conclusion RLX resin cement showed better hardness results. All materials tested performed satisfactorily for sorption and solubility according to ISO 4049:2009. All materials showed high-staining values after 1 week of immersion in coffee.

12 August 2020 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
PDF file
MVMateus Do Vale Voigt
Mateus Do Vale Voigt
LELuís Felipe Espindola-Castro
Luís Felipe Espindola-Castro
GMGabriela Queiroz de Melo Monteiro
Gabriela Queiroz de Melo Monteiro
LOLeonardo Santiago Ortigoza
Leonardo Santiago Ortigoza
ATAdilson dos Santos Torreão
Adilson dos Santos Torreão
RGRalph Georg
Ralph Georg

1 January 2025 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
MSMg. Souza
Mg. Souza
EVEe. Vasconcelos
Ee. Vasconcelos
CHCt. Haur
Ct. Haur
NONg. Oliveira
Ng. Oliveira
GMGq. Monteiro
Gq. Monteiro
LELuís Felipe Espindola-Castro
Luís Felipe Espindola-Castro
To evaluate the physical, chemical, and mechanical properties of the Stela Automix Bulk-fill resin composite / SDI (SBF) compared to the light-cured resin composites: Filtek Bulk Fill Flow / Solventum (FBF) and Opus Bulk Fill Flow / FGM (OBF). The properties assessed were microhardness, sorption, solubility, color stability, and degree of conversion. Ten samples measuring 15 mm (diameter) and 1 mm (thickness) of each material were fabricated (ISO 4049:2019). The samples were prepared and analyzed using standardized methods, including Vickers microhardness testing, sequential weighings on an analytical balance for sorption and solubility tests, CIELAB spectrophotometry for color stability assessment, and FTIR spectroscopy for determining the degree of conversion. The self-curing resin composite exhibited higher microhardness (p < 0.001) and degree of conversion (p = 0.009), as well as sorption and solubility values within acceptable limits, in accordance with ISO 4049:2019. However, the material exhibited greater staining in coffee, which may compromise its aesthetics. The self-curing resin composite tested demonstrates good overall performance and is a promising material for restorations requiring greater depth. Clinical significance: To minimize the inconvenience of pigmentation that this material undergoes, it is recommended to use it as a base material and cover it with another resin composite that offers superior color stability.

5 June 2019 in Revista Ciência Plural
Verified
Journal Article
Open access
PDF file
LELuís Felipe Espindola-Castro
Luís Felipe Espindola-Castro
LOLeonardo Santiago Ortigoza
Leonardo Santiago Ortigoza
GMGabriela Queiroz de Melo Monteiro
Gabriela Queiroz de Melo Monteiro
Lentes de contato dentais podem ser uma excelente opção para correção de cor, forma, tamanho e posicionamento dental. Entretanto é um tratamento que requer várias etapas laboratoriais com riscos de distorções nas etapas de moldagem e vazamento do modelo. Desta forma, desadaptações dos laminados em boca podem ser frequentes. Objetivo: relatar um caso clínico de nove laminados cerâmicos em que foi empregado o escaneamento digital, troquelização virtual e prototipagem do modelo em 3D. Método: paciente do gênero feminino, 59 anos, buscou atendimento odontológico queixando-se de desproporcionalidade dentária ao sorrir. Ao exame clínico foi observada uma inclinação maxilar que causava aquela desarmonia. Foi proposta a confecção de laminados cerâmicos para compensar a discrepância óssea bem como melhorar forma, contorno e cromia dentária. Após planejamento digital, confecção do enceramento diagnóstico, mock up, e aceita do planejamento por parte da paciente, iniciaram-se os preparos dentários. Finalizada esta etapa, os dentes foram escaneados (Trios 3Shape), troquelizados e prototipados em impressora 3D. O modelo foi encaminhado ao laboratório que confeccionou as peças protéticas em dissilicato de lítio de forma injetada e maquiada. Por fim, foram realizadas as provas secas, úmidas, ajustes necessários e cimentação dos laminados com cimento resinoso fotopolimerizável. Conclusão: a tecnologia empregada se mostrou eficiente na resolução do caso, sendo uma técnica rápida, que causou pouco desconforto à paciente e oportunizou uma boa adaptação dos laminados cerâmicos.