Background: In the era of artificial intelligence, event prediction models are abundant. However, considering the limitation of the electronic medical record–based model, including the temporally skewed prediction and the record itself, these models could be delayed or could yield errors. Objective: In this study, we aim to develop multiple event prediction models in intensive care units to overcome their temporal skewness and evaluate their robustness against delayed and erroneous input. Methods: A total of 21,738 patients were included in the development cohort. Three events—death, sepsis, and acute kidney injury—were predicted. To overcome the temporal skewness, we developed three models for each event, which predicted the events in advance of three prespecified timepoints. Additionally, to evaluate the robustness against input error and delays, we added simulated errors and delayed input and calculated changes in the area under the receiver operating characteristic curve (AUROC) values. Results: Most of the AUROC and area under the precision-recall curve values of each model were higher than those of the conventional scores, as well as other machine learning models previously used. In the error input experiment, except for our proposed model, an increase in the noise added to the model lowered the resulting AUROC value. However, the delayed input did not show the performance decreased in this experiment. Conclusions: For a prediction model that was applicable in the real world, we considered not only performance but also temporal skewness, delayed input, and input error.
Background/Objectives: Data availability can affect the performance of AI-based early warning scores (EWSs). This study evaluated how the extent of missing data and imputation strategies influence the predictive performance of the VitalCare–Major Adverse Event Score (VC-MAES), an AI-based EWS that uses last observation carried forward and normal-value imputation for missing values, to forecast clinical deterioration events, including unplanned ICU transfers, cardiac arrests, or death, up to 6 h in advance. Methods: We analyzed real-world data from 6039 patient encounters at Keimyung University Dongsan Hospital, Republic of Korea. Performance was evaluated under three scenarios: (1) using only vital signs and age, treating all other variables as missing; (2) reintroducing a full set of real-world clinical variables; and (3) imputing missing values drawn from a distribution within one standard deviation of the observed mean or using Multiple Imputation by Chained Equations (MICE). Results: VC-MAES achieved the area under the receiver operating characteristic curve (AUROC) of 0.896 using only vital signs and age, outperforming traditional EWSs, including the National Early Warning Score (0.797) and the Modified Early Warning Score (0.722). Reintroducing full clinical variables improved the AUROC to 0.918, whereas mean-based imputation or MICE decreased the performance to 0.885 and 0.827, respectively. Conclusions: VC-MAES demonstrates robust predictive performance with limited inputs, outperforming traditional EWSs. Incorporating actual clinical data significantly improved accuracy. In contrast, mean-based or MICE imputation yielded poorer results than the default normal-value imputation, potentially due to disregarding the “informative presence” embedded in missing data patterns. These findings underscore the importance of understanding missingness patterns and employing imputation strategies that consider the decision-making context behind data availability to enhance model reliability.
Background: Acute deterioration of patients in general wards often leads to major adverse events (MAEs), including unplanned intensive care unit transfers, cardiac arrest, or death. Traditional early warning scores (EWSs) have shown limited predictive accuracy, with frequent false positives. We conducted a prospective observational external validation study of an artificial intelligence (AI)-based EWS, the VitalCare - Major Adverse Event Score (VC-MAES), at a tertiary medical center in the Republic of Korea. Methods: Adult patients from general wards, including internal medicine (IM) and obstetrics and gynecology (OBGYN)—the latter were rarely investigated in prior AI-based EWS studies—were included. The VC-MAES predictions were compared with National Early Warning Score (NEWS) and Modified Early Warning Score (MEWS) predictions using the area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve (AUPRC), and logistic regression for baseline EWS values. False-positives per true positive (FPpTP) were assessed based on the power threshold. Results: Of 6,039 encounters, 217 (3.6%) had MAEs (IM: 9.5%, OBGYN: 0.26%). Six hours prior to MAEs, the VC-MAES achieved an AUROC of 0.918 and an AUPRC of 0.352, including the OBGYN subgroup (AUROC, 0.964; AUPRC, 0.388), outperforming the NEWS (0.797 and 0.124) and MEWS (0.722 and 0.079). The FPpTP was reduced by up to 71%. Baseline VC-MAES was strongly associated with MAEs (P<0.001). Conclusions: The VC-MAES significantly outperformed traditional EWSs in predicting adverse events in general ward patients. The robust performance and lower FPpTP suggest that broader adoption of the VC-MAES may improve clinical efficiency and resource allocation in general wards.