Zhi de Zhou

Dr. Zhi de Zhou

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2022 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
XLXinhao Li
Xinhao Li
SLShengnan Li
Shengnan Li
QLQiuyan Lv
Qiuyan Lv
CWChaoxian Wang
Chaoxian Wang
JLJintao Liang
Jintao Liang
GLGuiyin Li
Guiyin Li

21 February 2023 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
JLJintao Liang
Jintao Liang
RYRuijie Yan
Ruijie Yan
CCChunguan Chen
Chunguan Chen
XYXiaoqing Yao
Xiaoqing Yao
FGFei Guo
Fei Guo
GLGuiyin Li
Guiyin Li

27 December 2022 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
XSXinjun Sun
Xinjun Sun
FFFengyan Fang
Fengyan Fang
JNJintong Na
Jintong Na
RYRunjie Yan
Runjie Yan
YHYong Huang
Yong Huang
GLGuiyin Li
Guiyin Li

13 April 2024 in Bioelectrochemistry
Verified
Journal Article
Closed access
GLGuiyin Li
Guiyin Li
HFHuafu Feng
Huafu Feng
XLXinhao Li
Xinhao Li
SLShengnan Li
Shengnan Li
JLJintao Liang
Jintao Liang
ZZZhi de Zhou
Zhi de Zhou

9 September 2023 in Microchemical Journal
Verified
Journal Article
Closed access
GLGuiyin Li
Guiyin Li
SLShengnan Li
Shengnan Li
QHQing Huang
Qing Huang
XLXinhao Li
Xinhao Li
ZZZhengyu Zhang
Zhengyu Zhang
ZZZhi de Zhou
Zhi de Zhou

1 November 2022 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
GLGuiyin Li
Guiyin Li
WLWenzhan Li
Wenzhan Li
SLShengnan Li
Shengnan Li
XLXinhao Li
Xinhao Li
XYXiaoqing Yao
Xiaoqing Yao
ZZZhi de Zhou
Zhi de Zhou
Glypican-3 (GPC3) is a membrane-associated proteoglycan that is specifically upregulated in hepatocellular carcinoma (HCC) and has become one of the most promising biomarkers closely related to the occurrence and development of HCC. In this work, platinum@palladium nanoparticles decorated with hemin-reduced graphene oxide (H-rGO-Pt@Pd NPs) were used not only as a support for GPC3 aptamer (GPC3Apt) immobilization, but also as a new redox nanoprobe in electrochemical analysis for the determination of GPC3. The electrochemical aptasensor involved a reaction cell with a three-electrode system, and the differential pulse voltammetry (DPV) technique was adopted. In the presence of GPC3, the formed GPC3Apt–GPC3 complexes had stable structures and were cleaved from the electrode surface, leading to more electroactive H-rGO-Pt@Pd NPs repelling freely from the GPC3Apt/H-rGO-Pt@Pd NPs and thus to the increase of the oxidation peak current of hemin in H-rGO-Pt@Pd NPs. Under optimal conditions and a working voltage of +700 mV (vs. Ag/AgCl), the label-free electrochemical GPC3 aptasensor showed superior performance with a wider concentration linear range (0.001–10.0 μg mL−1), a lower limit of detection (LOD) (0.181 ng mL−1, S/N = 3), a higher sensitivity (0.0446 μA μM−1 cm−2) and good selectivity. Furthermore, the fabricated aptasensor was applied to GPC3 determination in human serum samples with satisfactory recoveries of 94.3%–119% and RSDs of 0.15%–5.78%. The current work provides a flexible approach for the rapid and sensitive analysis of GPC3 and has a broad application prospect in the diagnosis of HCC.