Mustafa Al-Dulaimi

Dr. Mustafa Al-Dulaimi


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2022 in Heat Transfer
Verified
Journal Article
Closed access
PDF file
MAMustafa Al-Dulaimi
Mustafa Al-Dulaimi
KAKarima E. Amori
Karima E. Amori

27 April 2022 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
MAMustafa Al-Dulaimi
Mustafa Al-Dulaimi
KAKarima E. Amori
Karima E. Amori

1 February 2022 in Journal of Thermal Engineering
Verified
Journal Article
Closed access
PDF file
MAMustafa Al-Dulaimi
Mustafa Al-Dulaimi
FKFadhil Abdulrazzaq Kareem
Fadhil Abdulrazzaq Kareem
Faik  HamadFaik Hamad
Faik Hamad
This paper investigates numerically the influence of detached square vortex generator (VGs) on the heat transfer and pressure drop inside a square duct. Reynolds number is fixed at 5000. The geometrical parameters in this investigation are: i) The blocking ratios are 0.1, 0.15 and 0.2), ii) Vortex generator numbers are 1, 2, and 3), iii) Attack angles are 0, 30, and 45, iv) The aspect ratios are 1, 1.5 and 2. The numerical simulation is carried out using ANSYS FLUENT 15 . The results show that the rectangular vortex generators have a positive influence on heat transfer as a result of the augmentation in turbulence level. The maximum enhancement in average heat transfer could reach 40%. The heat transfer is found to increase with the blocking ratio. The heat transfer enhanced by 17% for one VG and 28% for 3 VGs for blocking ratio = 0.2. The VGs at angle value of 45° produce the highest heat transfer enhancement. The aspect ratio is found to have an adverse effect on heat transfer rate.

5 September 2018 in International Journal of Engineering & Technology
Verified
Journal Article
Closed access
PDF file
FKFadhil Abdulrazzaq Kareem
Fadhil Abdulrazzaq Kareem
MAMustafa Al-Dulaimi
Mustafa Al-Dulaimi
NLNoor Samir Lafta
Noor Samir Lafta
The performance of a forced draft wet cooling tower was investigated experimentally and the calculation was performed by applying second law of thermodynamics (exergy analysis). The mathematical model was developed by using engineering equation solver (EES) software. The results show that the chemical exergy of air increases from the bottom to the top of the cooling tower, the thermal exergy of air decreases from bottom to the top of the cooling, the exergy of water decreases from top to the bottom of the cooling tower. The exergy destruction decreases from bottom to the top of the cooling tower, and the exergy efficiency decreases from top to the bottom of the cooling. The exergy destruction tends to increase as the inlet wet bulb temperature increases while the exergy efficiency decreases. As water-air flow rate ratio increases the exergy destruction increases while the exergy efficiency decreases. The results show that there is an inverse proportional be-tween exergy destruction and exergy efficiency.

30 December 2019 in Journal of Mechanical Engineering and Sciences
Verified
Journal Article
Open access
PDF file
MAMustafa Al-Dulaimi
Mustafa Al-Dulaimi
FKF. A. Kareem
F. A. Kareem
FHF. A. Hamad
F. A. Hamad
This paper presents an experimental and numerical investigation of the thermal performance of natural draft wet cooling tower (NDWCT). The experimental investigation is carried out under natural draft condition and forced draft condition created by an axial fan. The operational parameters considered in this study are the thickness of the fill (10 and 20 cm), inlet water temperature (40, 45, and 50 °C) and inlet water volume flow rate (5.68, 7.75, and 9.46 L/min). The experimental results showed that the thermal performance is improved when the fans are used with the NDWCT. The temperature difference between inlet and outlet and effectiveness increase by 35% and 37.2%, respectively at fill thickness of 20 cm and water volume flow rate of 11.35 L/min. The temperature distribution of the air and the relative humidity were numerically simulated for both cases of natural and forced draft by employing the commercial CFD software ANSYS Fluent 15. The experimental and numerical results were validated with results from a previous work and showed a good agreement. The experimental results showed that the effectiveness increase by 22% and 30% for NDWCT and FDWCT respectively when in case of fill thickness 20 cm.

30 March 2023 in International Journal of Automotive and Mechanical Engineering
Verified
Journal Article
Open access
PDF file
MAMustafa Al-Dulaimi
Mustafa Al-Dulaimi
AHAreej H. Hilal
Areej H. Hilal
HHHusam A. Hassan
Husam A. Hassan
FHFaik A. Hamad
Faik A. Hamad
In this paper, the effect of using different configurations of absorber plate, including one line finned flat absorber and two lines finned absorber plate, on the thermal performance of a flat plate – double passing solar air heater was investigated experimentally. L- shape fins are soldered on the absorber plate to roughen the absorber plate and generate vortices to enhance the heat transfer between the working fluid (air) and absorber plate to improve the thermal efficiency. The outdoor experimental test was carried out during February and May under the weather conditions of Baghdad city (Longitude 33.3 N and Latitude 44.44 E). The results show that the air temperature is 48 ℃, 47.5 ℃, and 58.5 ℃ at an air velocity of 1.7 m/s for a single line of fins which increased to 52 ℃, 57.5 ℃, and 66 ℃ at air velocity of 0.9 m/s for two lines of fins. The efficiency is increased by 28% for one line of fins and 66% for two lines of fins at an air velocity of 0.9 m/s while increased by 27% for one line of fins and 51% for two lines of fins at an air velocity of 1.7 m/s. The average exergy destruction rate increases by 37.6%, 60.6%, and 68.66% for the absorber plate, working fluid, and glass cover, respectively, for velocity increase from 0.9 m/s to 1.9 m/s. The exergy efficiency increased by 24.1% when the velocity increased from 0.9 m/s to 1.9 m/s.