Yinglong Diao

Yinglong Diao

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2016 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WSWanxing Sheng
Wanxing Sheng
Keyan LiuKeyan Liu
Keyan Liu
HPHongyan Pei
Hongyan Pei
Yunhua LiYunhua Li
Yunhua Li
DJDongli Jia
Dongli Jia
YDYinglong Diao
Yinglong Diao
In this paper, a reactive power optimization method based on historical data is investigated to solve the dynamic reactive power optimization problem in distribution network. In order to reflect the variation of loads, network loads are represented in a form of random matrix. Load similarity (LS) is defined to measure the degree of similarity between the loads in different days and the calculation method of the load similarity of load random matrix (LRM) is presented. By calculating the load similarity between the forecasting random matrix and the random matrix of historical load, the historical reactive power optimization dispatching scheme that most matches the forecasting load can be found for reactive power control usage. The differences of daily load curves between working days and weekends in different seasons are considered in the proposed method. The proposed method is tested on a standard 14 nodes distribution network with three different types of load. The computational result demonstrates that the proposed method for reactive power optimization is fast, feasible and effective in distribution network.

22 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
WHWang Huan
Wang Huan
YDYinglong Diao
Yinglong Diao
WXWu Xixiu
Wu Xixiu
BDBolun Du
Bolun Du
The very fast transient overvoltage (VFTO) is characterized by steep wavefronts, high amplitude, and wide spectrum. These characteristics can lead to partial discharges or insulation breakdowns in potted insulators, which can lead to localized overheating or turn-to-turn insulation damage in transformers. The strong electromagnetic radiation generated by VFTO may also interfere with relay protection and communication systems, triggering risks to grid operation. This paper introduces the existing mainstream VFTO suppression methods, such as damping resistance method, disconnecting switch operation method, inductive method, etc., from the aspects of circuit structure, parameter design and suppression effect, and focuses on the influence of the material selection, parameter adjustment, and mounting structure adjustment of ferrite ring on VFTO suppression effect. In addition, the lightning arrester method and the method of utilizing overhead lines for VFTO suppression are also briefly discussed. The article concludes with a comparison of the advantages and disadvantages of each method and an outlook on the future research direction of VFTO suppression technology.

25 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ZLZhaozhi Long
Zhaozhi Long
FZFeng Zhou
Feng Zhou
FLFuchang Lin
Fuchang Lin
JFJiawei Fan
Jiawei Fan
WLWenting Li
Wenting Li
KHKangmin Hu
Kangmin Hu
High-voltage electric field measurement technology has certain applications in electric field measurement of power systems, but due to the limitation of its measurement accuracy and bandwidth, it cannot be used for the measurement of lightning-impulse voltage. In order to calibrate the nonlinearity of the MV-level lightning-impulse voltage measurement system, this paper proposes the design and implementation of a high-precision inductive wideband electric field measuring sensor (EFMS). The influence of the metal shell on the electric field distribution was simulated, and the influence of the electric field non-uniformity coefficient was studied. The characteristics of the EFMS were tested, and the results showed that the EFMS can accurately reproduce the waveform of lightning-impulse voltage and power-frequency voltage, with a proportionality coefficient of 0.05664 V/(kV/m). In mostly uniform and extremely non-uniform fields, the nonlinearity of the EFMS for impulse voltage is less than ±0.25%, and the nonlinearity of the EFMS for power-frequency voltage is less than 0.1%. It is shown that the EFMS can be used for the nonlinearity calibration of ultra-high voltage impulse measurement devices.

14 May 2025 in IEEE Access
Verified
Journal Article
Open access
Feng ZhouFeng Zhou
Feng Zhou
ZCZhenghao Chai
Zhenghao Chai
YDYinglong Diao
Yinglong Diao
ZLZhaozhi Long
Zhaozhi Long
The growing demand for high-precision sensing technologies in power systems has po-sitioned the development of novel electric field measurement tools as a critical metro-logical challenge. This study presents a broadband photoelectric electric field sensor based on the Mach-Zehnder interference phenomenon in asymmetric straight wave-guides. Furthermore, a three-dimensional electric field measurement system was de-veloped through systematic investigation of multidimensional field measurement methodologies. Experimental results demonstrate that the proposed device achieves broadband electric field measurement with linearity up to 0.9996 and pow-er-frequency measurement accuracy exceeding 97%. The system demonstrates con-current measurement capability for both lightning impulse waveforms and operation-al power frequency electric fields. The synthesized three-dimensional measurement error remains below 4%, enabling precise omnidirectional electric field detection.

29 April 2025 in Electronics
Verified
Journal Article
Open access
PDF file
HWHuan Wang
Huan Wang
WXWu Xixiu
Wu Xixiu
YDYinglong Diao
Yinglong Diao
XCXiwen Chen
Xiwen Chen
BDBolun Du
Bolun Du
Very fast transient overvoltage (VFTO) is characterized by short wavefront time, high amplitude and wide frequency. VFTO poses a threat to the safe operation of power equipment. In order to suppress the harmful effects of VFTO transmission on power equipment, a new type of busbar based on the structure of “inductance + resistance” has been designed, which is called a “damping busbar”. In this study, the equivalent circuit of a damping bus including spurious parameters was developed. These stray parameters are formed between the GIS enclosure and the damping bus, and between the disk insulators and the damping bus. A damping bus simulation model was established based on the equivalent circuit to carry out analysis of the relationship between the structural parameters of the damping bus and the inductance generated by the damping bus. The simulation results showed that the number of turns plays a decisive role in bus inductance, and the relationship between the number of turns and inductance is approximately linear. Comparative analysis of multiple waveforms was carried out before and after the addition of damping buses to the GIS on a 550 kV test rig. The test data showed that the average amplitude of VFTO decreased by 20.36% after the installation of the damping bus, the number of breakdowns decreased by about 66.7%, and there was no obvious high frequency in the measured waveform after installation. In short, the damping busbar had a good suppression effect on the amplitude and frequency of VFTO, and reduced the number of breakdowns. This technique provides a novel solution for VFTO suppression.

27 October 2024 in Electronics
Verified
Journal Article
Open access
PDF file
LWLewei Wang
Lewei Wang
ZLZhenhua Li
Zhenhua Li
HLHeping Lu
Heping Lu
Feng ZhouFeng Zhou
Feng Zhou
YDYinglong Diao
Yinglong Diao
To achieve the broadband applicability of standard voltage transformers in “dual high” power systems, an equivalent circuit model of the standard voltage transformer is first established. Using the complex magnetic permeability method and utilizing existing core parameters, the excitation impedance values are obtained. Next, based on the equivalent circuit model, the no-load error function of the standard voltage transformer is analyzed, and through simulation, the no-load error response curve of the standard voltage transformer in the frequency range of 20 Hz to 3000 Hz is derived. The simulation results indicate that within the 20 Hz to 700 Hz range, both the no-load ratio error and the no-load angular error meet the accuracy requirements, with the ratio error within ±0.05% and the angular error within 2′. Additionally, the derivation of the error transfer function demonstrates the correlation between the no-load error values and the number of turns and cross-sectional area of the standard voltage transformer. Simulation results, obtained by increasing and decreasing the number of turns and cross-sectional area by 10%, provide valuable insights for the error compensation and structural design of standard voltage transformers.