Rui Wang

Dr. Rui Wang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2020 in International Journal of Chemical Reactor Engineering
Verified
Journal Article
Closed access
PDF file
Omar BashaOmar Basha
Omar Basha
RWRui Wang
Rui Wang
IGIsaac Gamwo
Isaac Gamwo
NSNicholas S. Siefert
Nicholas S. Siefert
Badie I MorsiBadie I Morsi
Badie I Morsi
A full-scale multi-environment Eulerian CFD model for a countercurrent packed-bed absorber with structured packing Mellapak 250Y was built in ANSYS Fluent 2019 R1 in order to model CO2capture using physical solvents. The objective of the model is to predict the overall absorber gas-liquid internal flow profiles within the complex packing geometry, while accurately predicting the hydrodynamic parameters, such as liquid holdup and pressure drop. The gas-solid and gas-liquid drag coefficients were fitted and validated using the following experimental data by Green et al. (2006. “Hydraulic Characterization of Structured Packing via X-ray Computed Tomography”; 2007. “Novel Application of X-ray Computed Tomography: Determination of Gas/liquid Contact Area and Liquid Holdup in Structured Packing.”Industrial & Engineering Chemistry Research46: 5734–53.): dry pressure drop, irrigated pressure drop, and liquid holdup. The validated CFD model was used to study the effect of liquid distributor design on the liquid distribution in the absorber using three distributors provided with seven, thirteen, and twenty orifices of 0.2 mm diameter. The CFD model predictions revealed that the distributor with the largest number of orifices resulted in the least liquid maldistribution in the absorber, which led to increasing the overall CO2absorption efficiency in Selexol as a physical solvent. Also, the overall CO2absorption efficiency decreased with increasing the superficial liquid velocity due to the shorter contact times between CO2and Selexol in the absorber at higher superficial liquid velocities.

13 October 2022 in Journal of Energy and Power Technology
Verified
Journal Article
Open access
PDF file
RWRui Wang
Rui Wang
HAHusain E Ashkanani
Husain E Ashkanani
Bingyun LiBingyun Li
Bingyun Li
Badie I MorsiBadie I Morsi
Badie I Morsi
A unique two-Pathways process using aqueous sodium glycinate for CO2 capture from a split flue gas stream emitted from 600 MWe post-combustion coal power plant was developed in Aspen Plus v.10. The split gas flow rate used was 44.75 ton/h and contained 0.0023 mol% SO2 and 13.33 mol% CO2. The process includes a washing unit, a CO2 absorption unit, a reverse osmosis unit, and a solvent regeneration unit or an ultrafiltration unit. The washing unit uses deionized water to completely remove SO2 and the CO2 absorption unit uses SGS to capture at least 90 mol% of the CO2 in the split flue gas stream. Upon CO2 and SGS reactions, the resulting liquid products exhibit phase-separation into CO2-lean phase and CO2-rich phase, allow two distinct pathways. Pathway (i) is to regenerate mostly the CO2-rich phase, collect the released CO2, and compress it for sequestration purposes. Pathway (ii) is to send the liquid stream from the CO2 absorption unit to the ultrafiltration unit to separate the solid nanomaterials. The hydraulics and mass transfer characteristics in the washing and CO2 absorption units were obtained; and techno-economic analysis (TEA) for Pathways (i) and (ii), including Capital Expenditure (CAPEX), Operating Expenditure (OPEX), and Levelized Cost of CO2 Captured (LCOC), were calculated and compared. The simulation results revealed that the CAPEX, OPEX, and LCOC for Pathway (i) were (\$12,039,251), (261 \$/h), and (54.01 \$/ton-CO2 captured), respectively, and those for Pathway (ii) were (\$5,908,000), (237.2 \$/h), and (39.90 \$/ton-CO2 captured), respectively. Moreover, in Pathway (ii), 8.19 ton/h of CO2 were captured to produce 15.62 ton/h NaHCO3 nanomaterials, which were sold to offset the overall process cost. The LCOC values indicate that Pathway (ii) is more cost-effective than Pathway (i) because LCOC values for Pathway (ii) are much lower than those for Pathway (i).

21 November 2024 in Journal of Energy and Power Technology
Verified
Journal Article
Open access
PDF file
RWRui Wang
Rui Wang
Omar BashaOmar Basha
Omar Basha
HAHusain E Ashkanani
Husain E Ashkanani
Bingyun LiBingyun Li
Bingyun Li
Badie I MorsiBadie I Morsi
Badie I Morsi
CO2 capture processes using five chemical solvents were modeled in Aspen Plus V.12.1 for the capture of over 90% CO2 from a 456 ton/hour split flue gas stream containing 12.02 mol% CO2 emitted by the Longview 780 MW power plant (West Virginia, USA). Since the flue gas contained 33.10 ppmv SO2 and 35.47 ppmv NO2, a gas polishing process, using deionized water (DIW), was included in the model for complete scrubbing of SO2 and NO2 from the raw flue gas before the CO2 capture process. The five chemicals used for CO2 capture included three amine-based solvents (ABs) (monoethanolamine (MEA), 2-amino-2-methyl-1-propanol (AMP), and (piperazine/methyldiethanolamine (PZ/MDEA)), and two amino acid-based solvents (AAs) (sodium glycinates (SGS) and potassium glycinates (PGS)). Since SGS and PGS exhibit phase separation, the CO2 capture processes followed two distinct pathways: Pathway (i) involved direct CO2 capture using all five solvents, and Pathway (ii) focused on bicarbonate nanomaterials production using only SGS and PGS. A Techno-economic assessment (TEA) of the CO2 capture processes was conducted and the corresponding process hydraulics and mass transfer characteristics were calculated. The simulation results revealed the following: (1) for Pathway (i), the levelized cost of CO2 capture (LCOC) for PGS was lower than that for SGS, MEA, AMP, and PZ/MDEA; (2) for Pathway (ii), PGS had a lower LCOC than SGS; (3) Pathway (ii) was more economically more favorable than Pathway (i); and (4) under the operating conditions used, the two-phase pressure drop values were negligible, and the liquid-side mass transfer coefficients (kL) were an order of magnitude smaller than gas-side mass transfer coefficients (kG), suggesting that the gas-liquid mass transfer resistance (1/kL) was in the liquid-side. Our techno-economic analysis (TEA) underscores the uniqueness of using AAs solvents in industrial CO2 capture, offering significant cost savings through the production of valuable bicarbonate nanomaterials.