The Virtual Synchronous Generator (VSG) control strategy has garnered widespread application during the low-voltage ride-through (LVRT) of distributed energy resources integrated into power grids, primarily due to its inertia and damping properties. However, grid voltage dips frequently coincide with unbalanced conditions and harmonic disturbances, against which traditional VSG LVRT control strategies offer limited resilience, resulting in unbalanced and unstable grid-connected currents. Consequently, this impacts the VSG’s support for voltage at the point of common coupling (PCC) during LVRT, potentially leading to control system failure. To tackle this challenge, this paper introduces a VSG LVRT control strategy tailored for complex grid faults. Initially, a mathematical model is developed to analyze the impact on the VSG control system’s grid-connected current when the PCC voltage of the LC filter experiences harmonic-laden unbalanced dips. Subsequently, the traditional dual second-order generalized integrator phase-locked loop (DSOGI-PLL) is enhanced to bolster its filtering capabilities. Additionally, PCC voltage feedforward control is incorporated, with a meticulously derived feedforward function to counteract the disturbances caused by unbalanced grid voltage dips, thereby enhancing the VSG system’s anti-interference ability and stabilizing the grid-connected current. This enables effective VSG LVRT control in the face of complex grid faults and ensures successful LVRT of the grid-connected system. Ultimately, the efficacy of the proposed control strategy is confirmed through PSCAD simulations.
Under the background of high permeability, voltage feedforward control may further weaken the stability of grid-connected inverter (GCI) systems and may cause sub-synchronous oscillation in extreme cases. To solve this problem, this paper firstly considers the influence of the frequency coupling effect and voltage feedforward control, and adopts the harmonic linearization method to construct the L-type GCI sequence admittance model with PI (proportional integral) control and PR (proportional resonant) control, respectively. By comparing the sequence admittance characteristics of the GCI under two control strategies, combined with the sequence admittance model and Nyquist criterion, this paper analyzes the influence of voltage feedforward and control parameters on the stability of the GCI under two control strategies. The results show that the stability of GCI under PR control is slightly better than that under PI control. At the same time, the voltage feedforward control does reduce the stability of the GCI system under the two control strategies. Finally, the accuracy of the theoretical analysis is verified by simulation and experiment.