Micro-magnets producing magnetic field gradients as high as 106 T m−1 have been used to efficiently trap nanoparticles with a magnetic core of just 12 nm in diameter. The presented effect is based on the often-neglected particle–fluid two-way coupling leading to magnetophoretic convection.
The magnetically localized and wash-free fluorescence immunoassay (MLFIA) is a no-wash assay for directly measuring biomolecule (antigen and antibody) concentration, without mixing nor washing steps, from a body fluid (serum and plasma).
Aim: We present a fast magnetic immunoassay, combining magnetic nanoparticles and micromagnets. High magnetic field gradients from micromagnets are used to develop a new approach to the standard ELISA. Materials & methods/results: A proof-of-concept based on colorimetric quantification of antiovalbumin antibody in buffer is performed and compared with an ELISA. After optimization, the magnetic immunoassay exhibits a limit of detection (40 ng/ml) and a dynamic range (40–2500 ng/ml) similar to that of ELISAs developed using same biochemical tools. Conclusion: Micromagnets can be fully integrated in multiwell plates at low cost to allow the efficient capture of immunocomplexes carried by magnetic nanoparticles. The method is generic and permits to perform magnetic ELISA in 30 min.
Sexually transmitted infections (STI) remain one of the world's public health priorities: Nearly 400 million people are infected not only in emerging, but also in western countries. HIV, HBV and HCV share common infection pathways; thus these 3 diseases are recommended to be tested at the same time. However, this combined approach is currently mainly available in laboratories, and seldomly at the Point-of-care (POC). Consequently, there is a need for a STI screening POC platform with laboratory-like performance. Such a platform should be autonomous and portable and enable multiplexed screening from capillary blood. The previously developed and introduced MLFIA (Magnetically Localized and wash-free Fluorescent Immuno-Assay) technology has the potential to address these needs, as the MLFIA 18-chamber microfluidic cartridge and the MLFIA Analyzer were previously characterized and evaluated with plasma and serum from patients infected with HIV, Hepatitis B (Hep B) or C (Hep C). Here, we present the efforts to transfer this research platform (MLFIA) to a fully integrated multi-analysis solution (MagIA). First, we present the design changes of the consumable enabling to perform multiple assays in parallel, a fast filling of the cartridge with patient samples, and a homogeneous reagent/sample incubation. Second, we describe the development a piezoelectric actuator integrated into the Analyzer: this mixing module allows for an automated, fully integrated and portable workflow, with homogeneous in-situ mixing capabilities. The obtained MagIA platform was further characterized and validated for immunoassays (LOD, cartridge stability over time), using various biological models including OVA and IgG. We discuss the performances of the MLFIA and MagIA platforms for the detection of HIV / Hep B / Hep C using results from 102 patient plasma samples. Lastly, we assessed the compatibility of the MagIA platform with veinous and capillary blood samples as a final step towards its POC validation.
Quantitative nucleic acid detection is widely used in molecular diagnostics for infectious diseases. Here, we demonstrate that the previously developed MLFIA (magnetically localized fluorescent immunoassay) has the potential to detect Polymerase Chain Reaction (PCR) and loop-mediated isothermal amplification (LAMP) products using biotinylated and fluorescent primers and streptavidin-coated magnetic nanoparticles. The functionalized nanoparticles separate amplified DNA from non-incorporated primers in situ, allowing the quantification of DNA products. We compare magnetically localized fluorescence detection to commercial technologies based on the DNA intercalation of fluorescent dyes. Our system allows the detection of PCR and LAMP products but is approximately 10 times less sensitive than standard commercial assays. Future optimizations, such as enhancing the signal-to-noise ratio and improving nanoparticle functionalization, could significantly increase sensitivity and bring it closer to current diagnostic standards. This work highlights the potential of magnetically localized fluorescence detection to detect DNA.
A micro-magnetofluidic chip for fast and collective transport of superparamagnetic nanoparticles over centimetric distances, at velocities reaching up to 1.4 mm s −1 , and enabling nucleic acid fluorescence detection by particle accumulation.