In the context of the global energy landscape restructuring driven by the “dual-carbon” goals, new energy storage technologies have emerged as a critical enabler for energy transformation and the development of a new power system. However, as these technologies advance and the market expands, ensuring safety remains a significant and long-term challenge. This paper focuses on the safety risk prevention and control of new energy storage systems. It systematically reviewed various new energy storage technology pathways and their associated potential risks. Furthermore, it analyzed the challenges and difficulties faced in safety risk prevention and control across different stages of new energy storage projects, including large-scale application, pilot demonstration, and R&D reserves. Considering the technical uncertainties in the future development of new energy storage, this study evaluated potential safety risks and proposed corresponding strategies and measures for risk management. By addressing these challenges, this study aims to safe-guard the security and reliability of new energy storage technologies, thereby supporting the construction of a robust and sustainable new power system.
With the continuous development of the times and the natural gas industry, the number of composite laying between natural gas pipelines and power channels has increased. Once a gas pipeline leaks, it is easy to enter the power channel and cause serious explosion accidents. This article uses ANSYS/Fluent numerical simulation software to establish a composite laying model for buried gas pipelines and conducts numerical simulation research on gas pipeline leakage, obtaining the leakage laws of gas under different pressure levels, leakage hole diameters, and soil types. The results show that the concentration of gas and leakage entering the power channel increases linearly with the increase in pressure. However, as the pressure continues to increase, the impact on diffusion weakens. It has been demonstrated that an increase in the diameter of the leakage hole results in accelerated diffusion, leading to an increased diffusion rate into the power channel. It is evident that the magnitude of the viscous resistance coefficient and inertial resistance coefficient of the soil directly correlates with the ease with which gas can diffuse within the soil.
Underground deep vertical spaces are a new form of architectural structure for the efficient use of land resources. However, their slender geometry can intensify smoke transport and thermal hazards during fires. Sealing is a potential emergency strategy, but its influence on smoke dynamics and flame extinction in deep shafts remains insufficiently quantified. This study investigates smoke transportation characteristics and flame self-extinction in a sealed deep vertical space using 1:26 reduced-scale experiments combined with CFD simulations. Across the tested conditions, sealing consistently increased the characteristic upper-shaft centerline temperature rise, with enhancements ranging from 43.2% to 374.9%. The vertical centerline temperature above the fire exhibits a segmented decay behavior: in the plume-rise region it follows a power-law trend, while the decay coefficient deviates from the ideal-plume expectation, consistent with the thermal shielding effect associated with the confined upper hot-gas layer. Under sealed conditions, a distinct “ghosting” flame behavior and eventual self-extinction were observed. The combined flame, thermal, and simulated flow-field evidence is consistent with an oxygen-limited interpretation, although this mechanism was not directly verified by gas-species measurements. Based on the reduced-scale dataset, the self-extinction time was normalized by the characteristic oxygen-consumption timescale , yielding , which provides a quantitative description of flame self-extinction under the tested sealed conditions.
With the large-scale deployment of hydrogen fuel cell buses, operational safety concerns have become increasingly prominent, particularly the risks associated with hydrogen leakage and subsequent explosion, which warrant thorough evaluation. Using the Computational Fluid Dynamics (CFD) simulation software, a three-dimensional physical model was constructed based on a specific hydrogen fuel cell bus prototype to systematically investigate the leakage and dispersion characteristics of hydrogen within the cabin, as well as the associated combustion and explosion hazards, under varying numbers of open windows and wind directions. The results indicate that hydrogen leakage in a confined space exhibits pronounced vertical concentration stratification. The number of open windows significantly influences the distribution of the hydrogen concentration field within the passenger cabin. However, when the number of open windows is held constant, the impact of different window opening locations on the hydrogen volume fraction at a given monitoring point is relatively minor. Furthermore, when the explosion overpressure generated by the ignition of the leaked hydrogen exceeds the ultimate load-bearing capacity of the window glass, the glass fractures, thereby achieving pressure relief. A comprehensive assessment reveals that the high-temperature thermal hazards induced by hydrogen combustion are significantly greater than the blast overpressure hazards in confined-space combustion and explosion scenarios.