Xiaowei Cao

Dr. Xiaowei Cao

Yangzhou University

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Talanta
Verified
Journal Article
Closed access
LBLiyan Bi
Liyan Bi
XWXiao Wang
Xiao Wang
XCXiaowei Cao
Xiaowei Cao
LLLuying Liu
Luying Liu
CBCongcong Bai
Congcong Bai
Lingxin ChenLingxin Chen
Lingxin Chen

18 September 2019 in RSC Advances
Verified
Journal Article
Open access
PDF file
CBCancan Bao
Cancan Bao
QNQiangqiang Niu
Qiangqiang Niu
ZCZi-Ang Chen
Zi-Ang Chen
XCXiaowei Cao
Xiaowei Cao
HWHui Wang
Hui Wang
Wenbo LuWenbo Lu
Wenbo Lu
Ultrathin nickel-metal–organic framework (Ni-MOF) nanobelts, [Ni20(C5H6O4)20(H2O)8]·40H2O (Ni-MIL-77), have been exploited successfully for the fabrication of a non-enzymatic urea sensor. Ni-MOF ultrathin nanobelts in alkaline media can be used as an efficient catalyst for urea electrooxidation. As a non-enzymatic urea sensor, Ni-MOF ultrathin nanobelts exhibit a high sensitivity of 118.77 μA mM−1 cm−2, wide linear range of 0.01–7.0 mM, and low detection limit of 2.23 μM (S/N = 3). The selectivity, stability and reliability of ultrathin Ni-MOF nanobelts towards urea oxidation are also investigated. Moreover, Ni-MOF ultrathin nanobelts were further used to detect urea in human body fluids. All these findings confirm that the urea sensor based on Ni-MOF ultrathin nanobelts is successfully prepared and promising for applications in medical diagnostics and environmental monitoring.

11 June 2022 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
XCXiaowei Cao
Xiaowei Cao
SGShengjie Ge
Shengjie Ge
WHWeiwei Hua
Weiwei Hua
XZXinyu Zhou
Xinyu Zhou
WLWenbo Lu
Wenbo Lu
YQYayun Qian
Yayun Qian
Circulating tumour DNA (ctDNA) has emerged as an ideal biomarker for the early diagnosis and prognosis of gastric cancer (GC). In this work, a pump-free, high-throughput microfluidic chip coupled with catalytic hairpin assembly (CHA) and hybridization chain reaction (HCR) as the signal cascade amplification strategy (CHA–HCR) was developed for surface-enhanced Raman scattering (SERS) assays of PIK3CA E542K and TP53 (two GC-related ctDNAs). The chip consisted of six parallel functional units, enabling the simultaneous analysis of multiple samples. The pump-free design and hydrophilic treatment with polyethylene glycol (PEG) realized the automatic flow of reaction solutions in microchannels, eliminating the dependence on external heavy-duty pumps and significantly improving portability. In the reaction region of the chip, products generated by target-triggered CHA initiated the HCR, forming long nicked double-stranded DNA (dsDNA) on the Au nanobowl (AuNB) array surface, to which numerous SERS probes (Raman reporters and hairpin DNA-modified Cu2O octahedra) were attached. This CHA–HCR strategy generated numerous active “hot spots” around the Cu2O octahedra and AuNB surface, significantly enhancing the SERS signal intensity. Using this chip, an ultralow limit of detection (LOD) for PIK3CA E542K (1.26 aM) and TP53 (2.04 aM) was achieved, and the whole process was completed within 13 min. Finally, a tumour-bearing mouse model was established, and ctDNA levels in mouse serum at different stages were determined. To verify the experimental accuracy, the gold-standard qRT–PCR assay was utilized, and the results showed a high degree of consistency. Thus, this rapid, sensitive and cost-effective SERS microfluidic chip has potential as an ideal detection platform for ctDNA monitoring.

1 September 2021 in Analytica Chimica Acta
Verified
Journal Article
Closed access
YMYu Mao
Yu Mao
YSYue Sun
Yue Sun
JXJin Xue
Jin Xue
WLWenbo Lu
Wenbo Lu
XCXiaowei Cao
Xiaowei Cao

25 September 2020 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
YQYanxia Qiao
Yanxia Qiao
RZRui Zhang
Rui Zhang
FHFangyuan He
Fangyuan He
WHWenli Hu
Wenli Hu
XCXiaowei Cao
Xiaowei Cao
Xuping SunXuping Sun
Xuping Sun
The electrode design is of considerable importance for developing enhanced electrochemical sensing platforms. Conductive metal–organic frameworks (MOFs), with high surface area, high conductivity, and large pore volume, possess an ideal architecture for the detection of molecules. In this study, we report the first electro-oxidation of glucose in an alkaline solution using conductive Ni-based metal–organic framework nanosheet arrays on carbon cloth (Ni-MOF NSAs/CC) as a non-noble metal catalyst. Compared with a number of ligands coordinated to nickel salt, 2,3,6,7,10,11-hexaaminotriphenylene hexahydrochloride was selected as the best ligand to synthesize Ni-MOF because it has the highest electrocatalytic activity for glucose oxidation. The 3D Ni-MOF NSAs/CC electrode, as multifunctional sensors, was used to detect glucose with a low detection limit of 0.57 μM (S/N = 3), a wide linear range of 0.001–7 mM, high sensitivity of 13428.89 μA mM−1 cm−2, and good selectivity. The results demonstrate that the as-prepared Ni-MOF NSAs/CC has considerable development and application potential for clinical medical testing.

6 August 2020 in RSC Advances
Verified
Journal Article
Open access
PDF file
JXJi Xia
Ji Xia
YLYifan Liu
Yifan Liu
MRMenglin Ran
Menglin Ran
Wenbo LuWenbo Lu
Wenbo Lu
LBLiyan Bi
Liyan Bi
XCXiaowei Cao
Xiaowei Cao
The accurate analysis of tumor related biomarkers is extremely critical in the diagnosis of the early stage cervical cancer. Herein, we designed a novel and inexpensive surface-enhanced Raman scattering-based lateral flow assay (SERS-based LFA) strip with a single test line, which was applied for the rapid and sensitive quantitative simultaneous analysis of SCCA and CA125 in serum samples from patients with cervical cancer. In the presence of target antigens, the monoclonal antibody-coupled and Raman reporter-labeled nano-Ag polydopamine nanospheres (PDA@Ag-NPs) aggregated on the test line modified by the polyclonal antibody to form a double-antibody sandwich structure. The finite difference time domain simulation demonstrated that large number of “hot spots” was generated among the nanogaps of aggregated PDA@AgNPs, which resulted in a huge enhancement of the signal of the Raman reporters. Accordingly, the limit of detection was determined to be 7.156 pg mL−1 for SCCA and 7.182 pg mL−1 for CA125 in phosphate buffer and 8.093 pg mL−1 for SCCA and 7.370 pg mL−1 for CA125 in human serum, revealing high sensitivity of this SERS-based LFA strip. Significantly, the detection of SCCA and CA125 using the SERS-based LFA was observed to have high specificity and reproducibility, and the whole detection was completed within 20 min. Furthermore, the SERS-based LFA and enzyme-linked immunosorbent assay were also employed in serum samples obtained from patients with cervical cancer, cervical intraepithelial neoplasia and healthy subjects, and perfect agreement existed between both the methods. Thus, clinically, the developed SERS-based LFA strip has strong potential for the simultaneous detection of multiple cancer biomarkers in serum.