Ertan Şahin

Prof. Dr. Ertan Şahin


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2024 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
EŞErtan Şahin
Ertan Şahin
TKTulay Kus
Tulay Kus
AAAlper Aytekin
Alper Aytekin
EUEvren Uzun
Evren Uzun
UEUmut Elboga
Umut Elboga
UCUfuk Cimen
Ufuk Cimen
Accurate staging of invasive lobular carcinoma (ILC), a subtype of breast cancer, is vital for effective clinical management. Although 18F-FDG PET/CT is a commonly used tool, its efficacy varies across different histologic subtypes. To mitigate this challenge, our investigation delves into the potential utility of 68Ga-fibroblast activation protein inhibitor (FAPI) PET/CT as an alternative for staging ILC, aiming to address a significant research gap using a more expansive patient cohort than the smaller samples commonly found in the existing literature. Methods: In this retrospective analysis, women diagnosed with primary ILC of the breast underwent both 18F-FDG PET/CT and 68Ga-FAPI PET/CT. Both modalities were compared across all lesion locations with the used reference standard. The interval between scans was 1 wk, without any intervening treatments. Lesions were categorized visually, and tracer activity was analyzed using SUVmax, tumor-to-background uptake ratio, and uptake ratios. Both modalities were compared across various parameters, and statistical analysis was performed using SPSS 22.0. A P value of less than 0.05 was chosen to determine statistical significance. Results: The study included 23 female ILC patients (mean age, 51 y) with hormone-positive, human epidermal growth factor receptor type 2–negative tumors. Most (65%) had the luminal A subtype. 68Ga-FAPI PET/CT outperformed 18F-FDG PET/CT, with higher tumoral activity and tumor-to-background uptake ratios (P < 0.001). Primary tumors showed significantly increased uptake with 68Ga-FAPI PET/CT (P < 0.001), detecting additional foci, including multicentric cancer. Axillary lymph node metastases were more frequent and had higher uptake values with 68Ga-FAPI PET/CT (P = 0.012). Moreover, 68Ga-FAPI PET/CT identified more lesions, including bone and liver metastases. Pathologic features did not significantly correlate with imaging modalities, but a positive correlation was observed between peritumoral lymphocyte ratio and 68Ga-FAPI PET/CT–to–18F-FDG PET/CT uptake ratios (P = 0.026). Conclusion: This study underscores 68Ga-FAPI PET/CT’s superiority over 18F-FDG PET/CT for ILC. 68Ga-FAPI PET/CT excels in detecting primary breast masses, axillary lymph nodes, and distant metastases; can complement 18F-FDG PET/CT in ILC; and holds potential as an alternative imaging method in future studies. Visual Abstract

1 September 2021 in European Journal of Radiology
Verified
Journal Article
Closed access
EŞErtan Şahin
Ertan Şahin
UEUmut Elboğa
Umut Elboğa
YÇYusuf Zeki Çelen
Yusuf Zeki Çelen
ÖSÖzlem Nuray Sever
Özlem Nuray Sever
YÇYusuf Burak Çayırlı
Yusuf Burak Çayırlı
UÇUfuk Çimen
Ufuk Çimen

1 January 2015 in Srpski arhiv za celokupno lekarstvo
Verified
Journal Article
Open access
PDF file
EŞErtan Şahin
Ertan Şahin
UEUmut Elboğa
Umut Elboğa
EKEbuzer Kalender
Ebuzer Kalender
Introduction. It is important to know the size of the thyroid gland, and its normal value may vary among different geographic regions. Objective. In this study, we aimed to establish reference ranges for thyroid volume in euthyroid adults and to compare these results with the literature data. Methods. Between June 2011 and June 2012, 461 patients with normal laboratory results (serum TSH, anti-TG, anti-TPO antibodies and urine iodine level) that underwent thyroid gland ultrasound examination were retrospectively analyzed. Two hundred and 92 patients were females and 169 were males; the age range was 18-61 years with mean age 30.84±9.97 years. Length, breadth and thickness were measured, and the volume of each lobe was estimated using the ellipsoid formula. Results. The overall mean thyroid volume in all patients who were examined was 12.98±2.53 mL. The mean thyroid volume in females and males was 12.09±2.05 mL and 14.53±2.55, respectively (p<0.05). The right thyroid lobe volume was greater than the left in all patients of both sexes. In addition, the study establishes a significant correlation between the thyroid volume and height, weight and body surface area of the subjects of both sexes (p<0.05). In the light of our findings we can provide reference values in order to evaluate patients who have thyroid hyperplasia or who are considered as normal. Conclusion. We consider that further studies are necessary to establish national references thyroid volume for each country.


1 January 2015
Verified
Journal Article
Closed access
EŞErtan Şahin
Ertan Şahin
UEUmut Elboga
Umut Elboga
EKEbuzer Kalender
Ebuzer Kalender
MBMustafa Basibuyuk
Mustafa Basibuyuk
HDHasan Deniz Demir
Hasan Deniz Demir
YCYusuf Zeki Celen
Yusuf Zeki Celen

12 July 2020 in Journal of Medical Imaging and Radiation Oncology
Verified
Journal Article
Closed access
PDF file
EŞErtan Şahin
Ertan Şahin
UEUmut Elboğa
Umut Elboğa