In the present study the experiments were conducted on steady-state that incorporated nine symmetric and asymmetric separate discrete integrated circuits (ICs), strategically positioned at different locations on a substrate board, both with and without phase-change material (PCM). These ICs were subjected to varying levels of heat flux. It has been noted that the temperature is highly influenced by variables such as the size and positions of integrated circuits (ICs), the heat flux applied to the ICs. Furthermore, the non-dimensional geometric distance parameter, λ, is notably affected by both the size and positioning of the ICs. It's observed that at a higher value of λ (0.19), the temperature decreases by 18.79% at a velocity of 3 m/s and by 26.48% at a velocity of 5 m/s without PCM. With PCM, the temperature drop is 23.58% at 3 m/s and 32.47% at 5 m/s. The correlation shows a regression of 0.97 and an RMS error of 0.012%. A proposed correlation establishes a connection between θ (non-dimensional temperature) and λ, suggesting that the maximum non-dimensional temperature (θ) decreases with an increase in λ. This implies that the maximum temperature of the integrated circuits (ICs) is reduced at higher λ values. These findings provide valuable insights for thermal design engineers, aiding them in optimizing the placement of integrated circuits (ICs) to improve the reliability and lifespan of the ICs.
20 October 2024 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
This study investigates the heat transfer and friction factor characteristics in a heat exchanger utilizing copper wavy (corrugated) twisted tape inserts. By inducing turbulent flow within the inner tube of the heat exchanger, these inserts generated increased turbulence, thereby enhancing heat transfer and causing a rise in pressure drop. The copper twisted tapes, with various twist ratios (TR=10.7, 8.5, 7.1), measured 1 meter in length and 14 mm in width. The heat exchanger's outer tube was made of mild steel, with an outer diameter of 0.0198 m and an inner diameter of 0.0142 m, while the inner tube was constructed of copper, with an outer diameter of 0.038 m and an inner diameter of 0.032 m. The overall length of the pipe-in-pipe heat exchanger was 1.4 m. Bulk mean temperatures were recorded at different positions for various water flow rates, and new correlations for the Nusselt number and friction factor were derived from the results for the twisted tape inserts. The Reynolds number ranged from 5000 to 17000. Comparative analyses revealed that the wavy twisted tape with a twist ratio of 7.1 provided the highest heat transfer rate, showing a 172% increase in the Nusselt number and a 32.11% increase in the friction factor relative to a smooth tube.
30 September 2024 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
This study explores the impact of wavy corrugated twisted tape inserts on enhancing heat transfer and reducing pressure drop in a double pipe heat exchanger. Cu inserts with twist ratios of 3.2, 4.2, and 5.2 were used to create turbulence in the inner tube. Varying water flow rates and measuring bulk mean temperatures at different points revealed significant improvements in heat transfer over smooth tubes. The insert with a 3.2 twist ratio achieved the highest Nusselt number increase (185%) and a 36.33% rise in the friction factor. These results highlight the effectiveness of wavy corrugated twisted tape inserts for optimizing heat transfer, with a 3.2 twist ratio identified as the most effective. Across Reynolds numbers from 4000 to 18000, Nusselt number increases were 77.75% for a 5.2 twist ratio, 167% for a 4.2 twist ratio, and 185% for a 3.2 twist ratio. Friction factors rose by approximately 10.42% for a 5.2 twist ratio, 32.54% for a 4.2 twist ratio, and 36.33% for a 3.2 twist ratio, demonstrating the relationship between twist ratio, heat transfer enhancement.
Friction and wear in dynamic parts is the primary reason for energy loss in gearbox lubrication system and this can be optimized by utilizing modified lubricant. The tribological nature of gearbox system is critically affected by factors such as type of lubricant, loading & speed etc. In latest years, multiple advanced oil and modern tribological techniques & instruments have been utilized to investigate behaviour of oil like pin on disc, Fourball tester etc. This paper presents comparative investigation of oil blended with additive for two different conditions using prediction model & RSM. The design of experimentations has been conducted by using response surface methodology. The value of inputs parameters such as concentration, load & sliding velocity ranges from 0.5 to 5 %, 60 to 100 N and 0.65 to 1.5 m/s, respectively are utilized to evaluate the outcomes of coefficient of friction and specific wear rate. At the end results from Prediction equations are compared with experimental literature based outcomes to signify the effect of parameters like blend %, load & Sliding speed. The Coefficient of friction model showed 47.57 % more closer outcomes as compared to the Specific wear rate model for specific variation of unknown parameters for pin on disc setup in oil.