Maddalena Menini

Dr. Maddalena Menini

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2025 in Cancers
Verified
Journal Article
Open access
PDF file
Marco SpadacciniMarco Spadaccini
Marco Spadaccini
MMMaddalena Menini
Maddalena Menini
DMDavide Massimi
Davide Massimi
TRTommy Rizkala
Tommy Rizkala
RSRoberto De Sire
Roberto De Sire
CHCesare Hassan
Cesare Hassan
Colorectal cancer (CRC) prevention depends on effective colonoscopy; yet variability in adenoma detection rates (ADRs) and missed lesions remain significant hurdles. Artificial intelligence-powered computer-aided detection (CADe) systems offer promising advancements in enhancing polyp detection. This review examines the role of CADe in improving ADR and reducing adenoma miss rates (AMRs) while addressing its broader clinical implications. CADe has demonstrated consistent improvements in ADRs and AMRs; largely by detecting diminutive polyps, but shows limited efficacy in identifying advanced adenomas or sessile serrated lesions. Challenges such as operator deskilling and the need for enhanced algorithms persist. Combining CADe with adjunctive techniques has shown potential for further optimizing performance. While CADe has standardized detection quality; its long-term impact on CRC incidence and mortality remains inconclusive. Future research should focus on refining CADe technology and assessing its effectiveness in reducing the global burden of CRC.

3 December 2025 in Endoscopy
Verified
Journal Article
Open access
PDF file
YMYuichi Mori
Yuichi Mori
UKUri Kopylov
Uri Kopylov
PSPieter Sinonquel
Pieter Sinonquel
AEAlanna Ebigbo
Alanna Ebigbo
EDEvelien Dekker
Evelien Dekker
TTTony Tham
Tony Tham
The European Society of Gastrointestinal Endoscopy (ESGE) has identified a critical need to establish structured training for safe and effective use of artificial intelligence (AI) in endoscopy. This manuscript presents the results of a formal Delphi consensus process and outlines the official ESGE position, offering a comprehensive curriculum for acquiring and maintaining the competence needed to exploit the benefit of using AI tools in endoscopy. The proposed framework defines the prerequisites in the preadoption phase, core training components, and requirements to maintain optimal implementation. Key recommendations include: (1) ensuring basic competency in standard endoscopy procedures; (2) acquiring foundational knowledge of AI principles; (3) implementing educational programs to enhance AI literacy; (4) recognizing and mitigating cognitive biases in human–AI interaction; (5) avoiding over-reliance on AI in clinical decision-making; and (6) continuous monitoring of key performance indicators throughout AI system integration.

13 February 2026 in Endoscopy
Verified
Journal Article
Closed access
PDF file
TRTommy Rizkala
Tommy Rizkala
NMNatasha Muench
Natasha Muench
MMMaddalena Menini
Maddalena Menini
MDMario Dinis-Ribeiro
Mario Dinis-Ribeiro
Background This study assessed the effectiveness of large language models (LLMs) in generating lay summaries for patient education on the management of precancerous lesions and early neoplasia in the stomach. Methods In this pilot study, we used a two-period, crossover, blinded design to compare a ChatGPT-4o summary versus a Digestive Cancers Europe (DiCE) summary. Two panels rated the materials: expert physicians and DiCE Patient Advisory Committee members. Experts scored accuracy, completeness, comprehensibility, and satisfaction (across five sections); patients rated overall completeness, comprehensibility, and satisfaction. Paired comparisons used mixed-effects estimates. Readability was assessed with Flesch–Kincaid grade level (FKGL) and SMOG index. Results Median expert ratings were similar between materials across metrics. For the overall summary, median (range; IQR) scores were: accuracy 5 (4–6; 1) for ChatGPT-4o vs. 5 (3–6; 1) for DiCE (P = 0.10); completeness 4 (3–5; 1) vs. 4 (2–5; 1; P = 0.27); comprehensibility 4 (3–5; 1) vs. 4 (2–5; 1; P = 0.33); and satisfaction 4 (2–5; 1) vs. 3 (1–5; 2; P = 0.53). Patient ratings mirrored experts, with very similar results. Readability failed to meet guideline recommendations for both summaries on both FKGL and SMOG scores. Conclusion ChatGPT-4o produced patient materials comparable to DiCE, but both require readability optimization; a human-in-the-loop workflow and future tests across prompts and models are warranted. ‡ joint first authors. * joint senior authors. Received: 14 March 2025 Accepted after revision: 29 December 2025 Article published online: 13 February 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

21 February 2025 in Endoscopy
Verified
Journal Article
Closed access
PDF file
Marco SpadacciniMarco Spadaccini
Marco Spadaccini
CBCecilia Binda
Cecilia Binda
AMAurelio Mauro
Aurelio Mauro
RLRomain Legros
Romain Legros
MCMatteo Colombo
Matteo Colombo
Alessandro FugazzaAlessandro Fugazza
Alessandro Fugazza
Biliary drainage in patients with distal malignant biliary obstruction (DMBO) carries a higher risk of difficult biliary cannulation (DBC) during endoscopic retrograde cholangiopancreatography (ERCP). After the failure of standard cannulation, endoscopists may proceed with advanced cannulation techniques and/or with endoscopic ultrasound-guided biliary drainage (EUS-BD).This was a retrospective study of consecutive patients with DMBO and a dilated common bile duct (CBD; >12 mm) who underwent ERCP for endoscopic biliary drainage in four European centers. The rates of DBC, technical and clinical success, and procedure-related adverse events (AEs) were assessed. The predictive factors for AEs were also investigated through regression analysis. The EUS-BD approach was considered either as the first option after standard cannulation failure or as the final option after advanced cannulation failure.1016 patients with DMBO were included in the study, with 524 (51.6%) matching the definition of DBC. Clinical success was achieved in 956 patients (94.1%). Procedure-related AEs were experienced by 167 patients (16.4%). Patients with DBC had a higher risk of AEs (P=0.003); however, patients undergoing “early” EUS-BD showed a risk of AEs comparable with those managed with standard cannulation (P=0.38). An attempt at any advanced cannulation technique was independently associated with the occurrence of AEs (P=0.001).The risk of AEs is higher in patients with DMBO and DBC, this appears to be mainly related to the advanced cannulation techniques. In patients with a dilated CBD (>12 mm), “early” EUS-BD may minimize the risk of AEs.

19 August 2025 in Endoscopy
Verified
Journal Article
Closed access
PDF file
MMMaddalena Menini
Maddalena Menini
CCCarlotta Crisciotti
Carlotta Crisciotti
MMMaddalena Menini
Maddalena Menini
TRTommy Rizkala
Tommy Rizkala
LSLuca Di Stefano
Luca Di Stefano
ARAlessandro Repici
Alessandro Repici
Gastrointestinal endoscopy is a major contributor of medical waste and greenhouse gas (GHG) emissions. Sustainable waste management practices could help reduce its environmental footprint.A prospective exploratory study was conducted at IRCCS Humanitas Research Hospital from April to June 2023. The intervention included installing recycling bins for paper and plastic in five endoscopy suites, alongside existing regulated medical waste (RMW) and non-regulated medical waste bins. Comprehensive staff training on waste segregation was provided, and a “Green Endoscopy” nurse monitored compliance during the intervention. Data on RMW, its emissions (in kg carbon dioxide equivalents [CO2e] per procedure), and costs were collected and compared with pre-intervention values.RMW production decreased by 24.1%, from 1.91 kg per procedure (95%CI 1.54–2.28) to 1.45 kg per procedure (95%CI 1.16–1.73; P = 0.02), with sustained reductions during follow-up (1.48 kg per procedure; 95%CI 0.84–2.12). The intervention led to a 33.3% reduction in GHG emissions (with a net difference of 1.23 kg CO2e per procedure; P = 0.02), and cost savings of approximately €3542 (±384) were achieved. This effect was consistent across different procedure types.Targeted interventions such as staff education and structured waste segregation protocols substantially reduced RMW and associated GHG emissions in a high-volume endoscopy unit. These results suggest that simple, low-cost changes may improve environmental sustainability in clinical practice.

3 September 2025 in Endoscopy
Verified
Journal Article
Closed access
PDF file
GAGiulio Antonelli
Giulio Antonelli
FDFederico Desideri
Federico Desideri
SSSara Schiavone
Sara Schiavone
NBNicolò Bevilacqua
Nicolò Bevilacqua
ADAndrea Dequarti
Andrea Dequarti
MMMaddalena Menini
Maddalena Menini
Accurate polyp size estimation during colonoscopy is crucial for clinical decision making, follow-up, and implementation of cost-saving strategies. Objective sizing methods are lacking, and interobserver variability is high. This prospective, multicenter, study evaluated the accuracy of a novel artificial intelligence (AI)-based algorithm for polyp size estimation. Patient aged ≥18 years undergoing colonoscopy for colorectal cancer (CRC) screening or surveillance were enrolled across three centers. Polyp size was initially assessed by operators using forceps/snare comparison (ground truth). Procedures were recorded, and AI-based polyp size estimates were obtained offline. The primary outcome was AI accuracy in size class determination (diminutive ≤5 mm, small 6–9 mm, large ≥10 mm). Secondary outcomes included size estimation in mm and impact on clinical management strategies. Among 465 polyps (307 diminutive, 107 small, 51 large) from 217 patients (mean age 61.9 [SD 10.4] years, 51.6% female), AI accuracy for size class determination was 85.8% (95%CI 82.5–88.8). Accuracy for diminutive, small, and large polyps was 93.3%, 74.6%, and 55.1%, respectively. The AI tool assigned 90.8% of patients to correct surveillance intervals and achieved mean absolute error of 1.13 mm and root mean square error of 1.40 mm for polyps ≤10 mm. The AI model performed similarly to expert endoscopists in clinically relevant size-related outcomes, potentially improving the accuracy and efficiency of CRC screening.