Bum-Joon Jung

Mr. Bum-Joon Jung

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
BJBum-Joon Jung
Bum-Joon Jung
JKJihye Kim
Jihye Kim
JKJeong-Ah Kim
Jeong-Ah Kim
HJHansol Jang
Hansol Jang
SSSumin Seo
Sumin Seo
WLWonhee Lee
Wonhee Lee
Inertial microfluidics has drawn much attention for its applications for circulating tumor cell separations from blood. The fluid flows and the inertial particle focusing in inertial microfluidic systems are highly dependent on the channel geometry and structure. Flexible microfluidic systems can have adjustable 3D channel geometries by curving planar 2D channels into 3D structures, which will enable tunable inertial separation. We present a poly(dimethylsiloxane) (PDMS)-parylene hybrid thin-film microfluidic system that can provide high flexibility for 3D channel shaping while maintaining the channel cross-sectional shape. The PDMS-parylene hybrid microfluidic channels were fabricated by a molding and bonding technique using initiated chemical vapor deposition (iCVD) bonding. We constructed 3D helical inertial microfluidic channels by coiling a straight 2D channel and studied the inertial focusing while varying radius of curvature and Reynolds number. This thin film structure allows for high channel curvature and high Dean numbers which leads to faster inertial particle focusing and shorter channel lengths than 2D spiral channels. Most importantly, the focusing positions of particles and cells in the microchannel can be tuned in real time by simply modulating the channel curvature. The simple mechanical modulation of these 3D structure microfluidic systems is expected to provide unique advantages of convenient tuning of cell separation thresholds with a single device.

2 August 2019 in Reaction Chemistry & Engineering
Verified
Journal Article
Closed access
PDF file
SJSeungwook Jang
Seungwook Jang
BJBum-Joon Jung
Bum-Joon Jung
MKMi-Jeong Kim
Mi-Jeong Kim
WLWonhee Lee
Wonhee Lee
DKDong-Pyo Kim
Dong-Pyo Kim
Reaction-volume dependent photocatalytic reduction of nitrobenzene was investigated in various batch reactors and continuous-flow microreactors (CFMs) with different surface area to volume ratios (SA/V) under visible-light irradiation, leading to control of the photochemical reduction route, reaction speed and product selectivity. A batch reactor with less than 1.5 cm−1 SA/V ratio produced only aniline in 96% selectivity with 40% conversion by a direct reaction route. In contrast, the CFM with an 80 cm−1 SA/V ratio showed production of high-value azoxybenzene in 99% selectivity with 99% conversion through a condensation reaction route. In particular, a parylene thin film microreactor with a 100 μm channel height (400 cm−1 SA/V ratio) achieved perfect conversion and selectivity to azoxybenzene within only 50 min of reaction, compared to 20 h of reaction in the batch reactor to produce aniline. The mechanistic reaction progress was monitored by conducting time-dependent reactions of nitrobenzene and nitrosobenzene. Furthermore, the photocatalysis of various nitro-aromatic compounds also exhibited the identical reaction-volume dependent chemistry with excellent product selectivity.

16 April 2026 in Small
Verified
Journal Article
Open access
BJBum-Joon Jung
Bum-Joon Jung
AHAllison Hohreiter
Allison Hohreiter
RCRunjie Chen
Runjie Chen
DCDylan Cook
Dylan Cook
LHLinus Hansen
Linus Hansen
ABAnindita Basu
Anindita Basu
Single‐cell analysis technologies are pivotal in unraveling complex bihological mechanisms, yet existing platforms are often limited to sequencing‐based end‐point measurements, which fail to capture live cell dynamics. Here, we present a microfluidic–microelectronic device, the Microfluidic Dielectrophoretic Arresting System (MiDAS) that employs dielectrophoresis (DEP) for high‐throughput single‐cell and droplet trapping in a compact array. We tested multiple trap geometries, including a 20 µm‐diameter DEP trap for polymer microbeads, fungal and mammalian cells, and a 40 µm‐diameter trap for water‐in‐oil droplets. The platform demonstrates broad sample compatibility, reliably immobilizing cells and beads of varying sizes. By integrating optical imaging and Raman spectroscopy, we enable interrogation of individual cells with temporal resolution. We describe different modes of MiDAS operation to trap and manipulate single‐cells or reverse emulsion droplets on demand, with applications in droplet microfluidics. Our MiDAS platform's simple fabrication, robust performance, and broad compatibility with diverse sample types position it as a versatile tool with transformative potential for single‐cell analysis, offering researchers an innovative approach to interrogate cellular dynamics with precision and throughput.

28 January 2025 in Advanced Functional Materials
Verified
Journal Article
Closed access
HHHaerang Hwang
Haerang Hwang
BJBum-Joon Jung
Bum-Joon Jung
JPJiho Park
Jiho Park
YJYujin Jeong
Yujin Jeong
YCYo‐Han Choi
Yo‐Han Choi
WLWonhee Lee
Wonhee Lee

3 September 2025 in bioRxiv
Verified
Preprint
Open access
BJBum-Joon Jung
Bum-Joon Jung
AHAllison Hohreiter
Allison Hohreiter
DCDylan Cook
Dylan Cook
LHLinus Hansen
Linus Hansen
STSunny Taylor
Sunny Taylor
ABAnindita Basu
Anindita Basu
Single-cell analysis technologies are pivotal in unraveling complex biological mechanisms, yet existing platforms are often limited to sequencing-based end-point measurements, which fail to capture live cell dynamics. Here, we present a microfluidic– microelectronic device, the Microfluidic dielectrophoretic Arresting System (MiDAS) that employs dielectrophoresis (DEP) for high-throughput single-cell and droplet trapping in a compact array. We tested multiple trap geometries, including a 20 μm-diameter DEP trap for polymer microbeads, fungal and mammalian cells, and a 40 μm-diameter trap for water-in-oil droplets. The platform demonstrates broad sample compatibility, reliably immobilizing cells and beads of varying sizes. By integrating optical imaging and Raman spectroscopy, we enable rapid, non-destructive interrogation of individual cells with temporal resolution. We describe different modes of MiDAS operation to trap and manipulate single-cells or reverse emulsion droplets on demand, with applications in droplet microfluidics. Our MiDAS platform’s simple fabrication, robust performance, and broad compatibility with diverse sample types position it as a versatile tool with transformative potential for single-cell analysis, offering researchers an innovative approach to interrogate cellular dynamics with unprecedented precision and throughput.

16 November 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
BJBum-Joon Jung
Bum-Joon Jung
NTNan Tian
Nan Tian
CPChristopher Colyn Petter
Christopher Colyn Petter
SMSai Rama Krishna Meka
Sai Rama Krishna Meka
MLMichael Justin Liptay
Michael Justin Liptay
JZJian Zhou
Jian Zhou
Microfluidic cell lysis is a critical front-end step in modern bioanalysis, determining how effectively intracellular nucleic acids, proteins, metabolites, and organelles can be released, preserved, and analyzed. This review discusses how microfluidic platforms are reshaping cell lysis by enabling precise control over sample volume, reaction time, transport, mechanical forces, electrical fields, heat transfer, and spatial compartmentalization. Rather than treating lysis as an isolated disruption process, this review examines it as an integrated engineering problem that must be matched to the target cell type, analyte class, and downstream analytical workflow. It first introduces the importance of lysis in bioanalytics and the advantages of microscale systems over conventional bench-scale methods. It then discusses the major design principles that govern on-chip lysis, including reagent delivery, physical force generation, selective membrane disruption, single-cell compartmentalization, and compatibility with amplification, spectroscopy, mass spectrometry, and sequencing. Subsequent sections compare how different microfluidic architectures support bulk processing, selective lysis, single-cell analysis, subcellular fractionation, and sample-to-answer diagnostics. Emphasis is placed on the trade-offs among lysis efficiency, analyte integrity, throughput, device complexity, reagent compatibility, and clinical or field deployability. The review also highlights emerging trends in hybrid lysis platforms, automated workflows, intelligent droplet manipulation, spatially resolved omics, and low-cost diagnostic systems. Finally, it identifies persistent bottlenecks, including debris-induced clogging, limited throughput for rare-cell samples, fabrication cost, and inconsistent benchmarking across studies. Overall, this review provides a framework for understanding and selecting microfluidic lysis strategies according to analytical purpose rather than technique alone.