Daniel Hengstler

Dr. Daniel Hengstler


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2012 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
PRP. C.-O. Ranitzsch
P. C.-O. Ranitzsch
JPJ.-P. Porst
J.-P. Porst
SKS. Kempf
S. Kempf
CPC. Pies
C. Pies
SSS. Schäfer
S. Schäfer
LGL. Gastaldo
L. Gastaldo

17 February 2024 in Physics
Verified
Journal Article
Open access
PDF file
BOBen Ohayon
Ben Ohayon
AAAndreas Abeln
Andreas Abeln
SBSilvia Bara
Silvia Bara
TCThomas Elias Cocolios
Thomas Elias Cocolios
OEOfir Eizenberg
Ofir Eizenberg
FWFrederik Wauters
Frederik Wauters
We, the QUARTET Collaboration, propose an experiment to measure the nuclear charge radii of light elements with up to 20 times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, Z=1,2) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei 3≤Z≤10 using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.

1 November 2015 in Physica Scripta
Verified
Journal Article
Closed access
PDF file
DHDaniel Hengstler
Daniel Hengstler
Marius KellerMarius Keller
Marius Keller
CSC Schötz
C Schötz
JGJ Geist
J Geist
MKM Krantz
M Krantz
CEChristian Enss
Christian Enss

2 November 2018 in Atoms
Verified
Journal Article
Open access
PDF file
SKSaskia Kraft-Bermuth
Saskia Kraft-Bermuth
DHDaniel Hengstler
Daniel Hengstler
PEPeter Egelhof
Peter Egelhof
CEChristian Enss
Christian Enss
AFAndreas Fleischmann
Andreas Fleischmann
TSThomas Stöhlker
Thomas Stöhlker
X-ray spectroscopy of highly charged heavy ions is an important tool for the investigation of many topics in atomic physics. Such highly charged ions, in particular hydrogen-like uranium, are investigated at heavy ion storage rings, where high charge states can be produced in large quantities, stored for long times and cooled to low momentum spread of the ion beam. One prominent example is the determination of the 1s Lamb Shift in hydrogen-like heavy ions, which has been investigated at the Experimental Storage Ring (ESR) at the GSI Helmholtz Centre for Heavy Ion Research. Due to the large electron binding energies, the energies of the corresponding photon transitions are located in the X-ray regime. To determine the transition energies with high accuracy, highly resolving X-ray spectrometers are needed. One concept of such spectrometers is the concept of microcalorimeters, which, in contrast to semiconductor detectors, uses the detection of heat rather than charge to detect energy. Such detectors have been developed and successfully applied in experiments at the ESR. For experiments at the Facility for Antiproton and Ion Research (FAIR), the Stored Particles and Atoms Collaboration (SPARC) pursues the development of new microcalorimeter concepts and larger detector arrays. Next to fundamental investigations on quantum electrodynamics such as the 1s Lamb Shift or electron–electron interactions in two- and three-electron systems, X-ray spectroscopy may be extended towards nuclear physics investigations like the determination of nuclear charge radii.

14 January 2023 in Atoms
Verified
Journal Article
Open access
PDF file
MHMarc Oliver Herdrich
Marc Oliver Herdrich
DHDaniel Hengstler
Daniel Hengstler
AFAndreas Fleischmann
Andreas Fleischmann
CEChristian Enss
Christian Enss
AGAlexandre Gumberidze
Alexandre Gumberidze
TSThomas Stöhlker
Thomas Stöhlker
With metallic-magnetic calorimeters (MMCs), promising detectors for high-precision X-ray spectrometry in atomic and fundamental physics experiments are available. In this work, we present a pilot experiment based on a maXs-30 type MMC-spectrometer for recording X-rays emitted in collisions of lithium-like uranium ions with a molecular nitrogen gas jet in the internal target of the ESR storage ring of the GSI. Sample spectra have been measured, and a multitude of X-ray transitions have been unambiguously identified. As a first test and for comparison with data recorded at an EBIT, the 2s Lamb shift in lithium-like uranium was estimated.

31 December 2022 in Atoms
Verified
Journal Article
Open access
PDF file
PPPhilip Pfäfflein
Philip Pfäfflein
GWGünter Weber
Günter Weber
SASteffen Allgeier
Steffen Allgeier
SBSonja Bernitt
Sonja Bernitt
AFAndreas Fleischmann
Andreas Fleischmann
TSThomas Stöhlker
Thomas Stöhlker
In this report, we compare two filter algorithms for extracting timing information using novel metallic magnetic calorimeter detectors, applied to the precision X-ray spectroscopy of highly charged ions in a storage ring. Accurate timing information is crucial when exploiting coincidence conditions for background suppression to obtain clean spectra. For X-rays emitted by charge-changing interactions between ions and a target, this is a well-established technique when relying on conventional semiconductor detectors that offer a good temporal resolution. However, until recently, such a coincidence scheme had never been realized with metallic magnetic calorimeters, which typically feature much longer signal rise times. In this report, we present optimized timing filter algorithms for this type of detector. Their application to experimental data recently obtained at the electron cooler of CRYRING@ESR at GSI, Darmstadt is discussed.