/ Kanar

Dr. / Kanar


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2024 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Open access
/K/ Kanar
/ Kanar
DTDilek Tagtekin
Dilek Tagtekin
BKBora Korkut
Bora Korkut
Objective: This study aimed to evaluate the accuracy of an intraoral scanner with near‐infrared imaging (NIRI) feature in the diagnosis of interproximal caries and to compare it with the visual‐tactile method (VTM), bitewing radiography (BWR), and panoramic radiography (PR).Materials and Methods: Six hundred thirty‐nine interproximal surfaces (mesial‐distal) of posterior teeth from 22 volunteers were examined. Results were scored by VTM, BWR, PR, and NIRI. Lesions were scored as 0 for no‐caries, 1 for early‐enamel lesion (EEL), and 2 for lesions involving dentino–enamel junction (DEJ). McNemar, Kappa, and Fleis Kappa tests were used to evaluate the agreement levels. Pearson's Chi‐square test was used to determine the matching rates after validation.Results: A good level of agreement was observed between examination methods (Ƙ = 0.613; p < 0.001). In pairwise comparisons, a moderate agreement was seen between all the methods for lesions with DEJ involvement, while a statistically good agreement was observed between BWR and NIRI (Ƙ = 0.675; p < 0.001). As a result of validation, the accuracy of NIRI for molars was considered 85.2% and 75.7% for premolars in EELs, 85.2% for molars, and 70% for premolars regarding the lesions involving DEJ.Conclusions: Intraoral scanners with the NIRI feature may be used for diagnosing interproximal caries, especially for permanent molars.Clinical Significance: Early detection of proximal caries is one of the most essential topics forming the basis of preventive dentistry. This study investigates a caries diagnostic tool integrated into intraoral scanners to diagnose interproximal caries. A caries diagnostic tool integrated into an intraoral scanner may prevent the harmful effects of ionizing radiation in early caries diagnosis and may improve the patient's oral health status.

21 February 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SMSimge Meseli
Simge Meseli
EAElif Alkan
Elif Alkan
BKBora Korkut
Bora Korkut
/K/ Kanar
/ Kanar
DTDilek Tagtekin
Dilek Tagtekin
This study assessed the bleaching and abrasiveness levels of different kinds of toothpaste with various RDA values on nanohybrid and microhybrid composite samples using a novel Press-on Force-Guided brushing simulator. One hundred and forty disc-shaped samples were prepared using two nano-hybrid and three microhybrid composites and divided randomly into four subgroups (n = 7). The samples were immersed in a coffee solution for 144 h and then brushed using R.O.C.S. (Remineralizing Oral Care Systems) brand toothpaste with different RDA values [Sensitive Instant Relief (SIR), Sensation Whitening (SW), and their combination with PRO Polishing (PP) (once a week)] using a brushing simulator for 140, 280 and 560 strokes (140 strokes correspondence to one week of real-time brushing). The level of surface roughness and color change (ΔE) were measured before and after the simulated brushing. Color changes were evaluated in Photoshop CC software through ∆E00* values generated from before and after L, a*, b* parameters on sample photographs taken by a mobile dental photography tool. The surface structure of samples was measured before and after the brushing using a profilometer. The measurements were analyzed in SPSS V23 software by Analysis of Variance and the Bonferroni Test, and the level of significance was set at <0.05. Regarding ΔE values comparisons, there were no significant differences between the toothpastes after 2 weeks of brushing. SW (2.82 ± 1.24), SIR + PP (2.78 ± 0.98), and SW + PP (2.84 ± 1.22) values were found to be similar after one month of brushing (p < 0.007). Regarding surface roughness comparisons between the toothpastes, two-week and one-month brushing values were found to be similar and statistically rougher than the initial values. Using R.O.C.S. PRO Polishing with low-abrasive toothpaste may increase the whitening effect by enhancing color recovery.

14 March 2025 in Lasers in Medical Science
Verified
Journal Article
Open access
PDF file
/K/ Kanar
/ Kanar
BKBora Korkut
Bora Korkut
DTDilek Tagtekin
Dilek Tagtekin
To investigate the relation between the caries scoring system of the fluorescence intraoral scanner (IOS) Trios 4 (3Shape, Denmark)a red laser light-induced fluorescence device DIAGNOdent Pen (Kavo, Germany), and the color parameters (L*a*b*) by a clinical contact type hybrid spectrophotometer Rayplicker (Borea, France) in the assessment of caries affected dentin tissue. Caries lesions were minimally invasively removal from 186 extracted molars. Teeth were scanned using Trios4, and the integrated software scored the cavity floor regarding the colors (yellow, initial caries; red, moderate-extensive caries) depending on the fluorescence features. Then the DIAGNOdent measurements were obtained from each cavity’s deep and discolored surface points following the previously obtained Trios4 colors. Thus, the Trios4 reading could be quantitatively assessed. Cross-polarization photographs were using the Rayplickerand L*a*b color parameters, and 3D Master (VITA) color mapping was obtained by using the RayPlicker’s software. Spearman’s Rho Correlation, Kappa, Mann Whitney-U, One-way Analysis-of-Variance, and Kruskal Wallis tests were used for the statistical analyses ( P < 0.05). Sensitivity, specificity and AUC were calculated. Trios4 and DIAGNOdent were positively correlated ( r = 0.733; P < 0.001). The L*parameter by Rayplicker and Trios4 was negatively correlated( r =-0.742; P < 0,001). The a*parameter by Rayplicker and Trios4 scoring positively correlated( r = 0.552; P < 0.001). No significant correlation was observed between b*parameter by Rayplicker and Trios4 ( r = 0.023; P = 0.760). DIAGNOdent readings according toTrios4 scorings were significant ( P < 0.001). The teeth without caries scored by the Trios4 corresponded to the median value of 29 in DIAGNOdent readings, and 88 for the teeth with caries (by Trios4 / yellow-red). The agreement between the Trios4 and DIAGNOdent was 52.2% for the specimens with no residual caries. The presence of caries scores by the Trios 4 corresponded to the DIAGNOdent readings of %100 for all the teeth evaluated. Regarding the RayPlicker assessments, 33% of the sound cavities corresponded to 2M3 color, and 73% corresponded to 5M3 color. Trios4 scorings presented 0.782 AUC, 56.30% sensitivity, and 100% specificity in DIAGNOdent reference. Trios4 scoring was considered coherent with the DIAGNOdent Pen. DIAGNOdent readings and the Level of L* and a* parameters in the dentin tissue might be considered interrelated. Fluorescence-featured scanner devices can be useful clinical tools to evaluate remaining dentin tissue during the caries removal procedure.

21 December 2024 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
/K/ Kanar
/ Kanar
DTDilek Tagtekin
Dilek Tagtekin
BKBora Korkut
Bora Korkut
FYFunda Yanıkoğlu
Funda Yanıkoğlu
BKBetül Kargül
Betül Kargül
This study aimed to evaluate the accuracy of laser fluorescence (LF) readings in detection of caries removal by various techniques (CRTs). A hundred and eighty extracted human molar teeth included in the study which were scored 3, 4, and 5 according to ICDAS. Each score group was randomly assigned to 4 subgroups according to CRT including ceramic bur (Group A), carbide bur (Group B), carbide bur with alumina abrasion (Group C), and carbide bur with bioactive glass (BAG) abrasion (Group D) (n = 15 for each group). A LF device (DIAGNOdent Pen, Kavo) was used to determine remaining caries. Histological sections of the teeth were examined under a dental operating microscope for validation. The data were analyzed using Fisher Freeman Halton, Fisher’s Exact, Pearson Chi-Square, Bonferroni Adjusted Z tests, ROC analysis, Kappa statistic and Binary Logistic Regression(p < 0.05). Histological examination revealed no significant differences among the CRTs and ICDAS scores (p > 0.05 for each). However, a significant difference was found between histological assessment and LF in ICDAS 5 score, specifically between Group B and Group D (p = 0.022), regarding caries presence. LF readings demonstrated over 0.9 area under curve (AUC) value regardless of CRT, except for ICDAS-4 score, and Group D in ICDAS-5 score. Overall, the AUC of LF was found to be 0.880 for the 38 cut-off point (p < 0.001), indicating a high level of accuracy. The univariate and multiple models showed the tested CRTs had no effect on the caries presence (p > 0.050). The CRTs examined in this study demonstrated similar efficacy in terms of caries removal. However, the application of bioactive glass on caries-affected dentin may lead to overestimations in the LF readings. Additionally, LF on the cavity floor may not be clinically suitable for teeth with ICDAS 4 scores. The clinical determination of caries removal endpoint is based on a multifactorial decision. However, when selective removal of soft dentin is performed, especially with bioactive glass abrasion in deep caries lesions, higher cut-off points might be determined in laser fluorescence readings to decide further operative intervention.

1 January 2024 in Journal of Oral Science
Verified
Journal Article
Open access
PDF file
/K/ Kanar
/ Kanar
SMSimge Meşeli
Simge Meşeli
BKBora Korkut
Bora Korkut
SKSerhat Köken
Serhat Köken
DTDilek Tağtekin
Dilek Tağtekin
FYFunda Yanıkoğlu
Funda Yanıkoğlu
Purpose: To compare the shear-bond-strength (SBS) of a highly-filled-flowable composite (HFFC) and a paste-type composite for indirect composite repair and to evaluate the effect of different surface treatments (ST), concerning the composite repair protocol.Methods: Eighty-four 5 × 5 × 2 mm cylindrical specimens were prepared using Gradia Plus and SR Nexco indirect composite materials. The samples were thermocycled 5,000 times. According to the ST, the samples were divided into three groups (control, bur, and air-abrasion). After ST, the sample subgroups were divided into two sub-groups according to the repair material: paste-type composite and HFFC (n = 7). Another 5,000 cycles of aging were performed. SBS values were measured with a universal testing machine (Shimadzu, Japan). Shapiro-Wilk, 3-way ANOVA, and Tukey HSD test were used to evaluate data (P < 0.05).Results: ST was considered significant for SBS (P < 0.001). The mean values were (13.9 ± 5.7), (17.0 ± 6.4), (20.4 ± 4.9) MPa for the control, bur and phosphoric acid, and air-abrasion groups, respectively. The surface treatment and repair material interaction was considered significant for SBS (P = 0.044). The highest mean bond strength (24.5 ± 4.5 MPa) was observed for the interaction of SR Nexco, air-abrasion ST, and HFFC repair.Conclusion: Repairing with HFFC following air abrasion might enhance the SBS for indirect composite restorations.

16 July 2024 in İstanbul Tıp Fakültesi Dergisi
Verified
Journal Article
Open access
/K/ Kanar
/ Kanar
DTDilek Tağtekin
Dilek Tağtekin
BKBora Korkut
Bora Korkut
FYFunda Yanıkoğlu
Funda Yanıkoğlu
This study aimed to calculate the volume loss percentages (VLP) regarding the ICDAS II system and various caries removal techniques (CRT) and to assess the microtensile bond strength (μTBS) in terms of VLP following CRT. Three-dimensional data of human extracted molars were acquired with an extraoral dental scanner (Ineos x5, Dentsply Sirona) before and after the caries removal. Each ICDAS score group (0,3,4 and 5) was divided into four subgroups according to the CRT: stainless steel bur (Group S), ceramic bur (Group C), tungsten carbide bur (TCB) and air abrasion (AA) with bioactive-glass (Group TB), and TCB and AA with Al2O3 (Group TA). Pre and post-caries removal data were overlaid in a 3D modeling software and were volumetrically measured (n=10). Following the restoration, samples were prepared with non-trimming technique and subjected to microtensile testing. ICDAS II scores were found related the VLP (p< 0.001) and the μTBS (p<0.001). CRT was not effective on VLP (p=0.110), whereas CRT type was significant on μTBS (p<0.001). In Group TA, a strong negative correlation was observed between the μTBS and the VLP for ICDAS 5 score (r=-0.919; p=0.027). ICDAS II can provide a preliminary indication for the amount of VLP and reduction in μTBS following caries removal. The use of 29 μm Al2O3 with air abrasion in deep caries removal may improve μTBS while potentially reducing the VLP.